Quadra-Fire QV32EV-B Wiring, 120VAC Wall Outlet Installation, 120VAC Hardwire Installation

Page 9

4Wiring

Model

Description

Voltage

Watts

Amps

￿

(120/240)

 

QV32E-B

31 in. fi replace

120

1400

12.5

 

 

 

 

 

 

 

QV32EV-B

31 in. fi replace

240

2600

12.5

 

Note: Follow all national and local electrical codes.

Note: This heater must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C2.1 as appropriate.

WARNING

Shock Risk

Fire Risk

Improperly protected power cords could cause electrical shock or fi re.

Do not pinch the cord or lay against a sharp object.

Do not cover the cord with carpeting, throw rugs or runners.

Secure and arrange cord to avoid a tripping hazard.

Do not coil cord.

All wiring must be done by a qualified electrician. Use appropriate wire to meet local and national codes for rated power consumption.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock Risk

Improperly grounded outlets could cause electrical shock.

Always use properly grounded, fused and polarized outlets.

Always used ground fault protection where required by electrical code.

A. 120VAC Wall Outlet Installation

The heater is The heater is wired from factory with a polarized plug.

For ease of electrical hook up, you may wish to install the heater near an existing outlet. A 15 amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit trips or fuse blows on a regular basis when the heater is operated. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

Before plugging heater into wall outlet, make sure all control switches are in the “OFF” position. To access the controls, lift up on the lower grille panel and rotate it forward.

￿• If the power cord is not being used, go to Step B below. If the cord does not reach the outlet, a No. 16-AWG minimum wire size extension cord rated for a minimum of 1875 watts may be used. Use minimum length and do not coil cord.

CAUTION

Disconnect remote controls during your extended absence. This will prevent accidental operation of the heater.

B. 120VAC Hardwire Installation

Turn off circuit breaker.

Access knockout.

Remove the access cover plate.

Disconnect the power cord from the terminal block.

Remove the knockout and install the cable clamp (not provided) into the hole.

Feed 8 in. of service wire through the cable clamp and secure.

Connect the black wire from the service to the L1 terminal.

Connect the white wire from the service to the N terminal.

Connect the green (ground) from the service to the GND terminal.

Optional wall switch wiring is to be done at this time.

Replace access cover plate.

Quadra-Fire • Village Collection Electric Fireplace • 4030-782 Rev D • 11/05

9

Image 9
Contents QV32E-B QV32EV-B Listing Label Information/Location Homeowner Reference InformationTable of Contents Certification Listing and Code ApprovalsGetting Started Important InstructionsNot intended for use as a primary heat source Fire Risk Tools and Supplies NeededSelecting Heater Location Framing and ClearancesClearances Electrocution RiskCeiling Framing120VAC Wall Outlet Installation Wiring120VAC Hardwire Installation Shock Risk Fire RiskWall Switch Wiring 12VDC 240VAC Hardwire InstallationSecure and Level the Heater Heater PreparationFinishing Finishing ChecklistFinishing Material Combustible MaterialCeiling MantelClean Heater Heater SetupAccessories Install RefractoryOperating Instructions Access ControlsManual Controls Function of Manual ControlsHand Held Remote Control Transmitter RCE-QUAD-B Optional Wall Switch Control FCC RequirementsCanadian Equipment Requirements Troubleshooting Troubleshooting GuideIssues Possible Causes Solutions Cleaning the Firebox and Control Compart- ment Maintenance and ServiceCleaning the Back Acrylic Panel Replacing the Light BulbsMaintenance Task List Heater/Blower Assembly MaintenanceReference Materials Heater DimensionsFronts Optional ComponentsSurrounds Trim KitsService Parts Service Parts Village CollectionQV32E-B Series Qty # Description of PartThis page intentionally left blank Limited Warranty WarrantyHearth & Home Technologies Inc North Highway Colville, WA Contact Information

QV32E-B, QV32EV-B specifications

The Quadra-Fire QV32EV-B and QV32E-B are high-efficiency gas stoves that combine modern aesthetics with cutting-edge technology. Designed for homeowners seeking warmth and style, these models stand out for their superb heat output and reliable performance.

One of the main features of the Quadra-Fire QV32EV-B and QV32E-B is their advanced heating capability. The stoves are capable of producing up to 32,000 BTUs, efficiently heating spaces while maintaining a clean, environmentally conscious burn. This energy-efficient performance makes them ideal for residential heating, offering consistent warmth during colder months.

Both models employ a unique, patented Easy Clean system, which simplifies maintenance by making it easier to access the stove's components. This feature ensures that the stove remains in optimal condition, allowing homeowners more time to enjoy the warm ambiance it creates rather than worrying about upkeep.

The QV32EV-B and QV32E-B are characterized by their sleek, contemporary design, featuring a large viewing window that provides an unobstructed view of the flickering flames, enhancing any room's atmosphere. Additionally, they can be customized with a variety of finishes and decorative choices, allowing users to perfectly match their decor.

These models come equipped with the Quadra-Fire Ember-Fire technology, which maximizes the visual appeal of the flames, creating a realistic, captivating fire experience. This technology not only enhances aesthetic pleasure but also improves the efficiency of the gas burn, contributing to the overall effectiveness of the unit.

The stoves feature a state-of-the-art electronic ignition system for ease of use. This enables users to ignite their stove with the push of a button, eliminating the need for fire starters or matches. The adjustable thermostat allows for precise temperature control, providing comfort tailored to individual preferences.

Safety is paramount in the design of the QV32EV-B and QV32E-B, as they incorporate features like a safety shut-off system that automatically turns off the stove in case of malfunction. The sturdy construction and high-quality materials ensure long-lasting durability, making these stoves a worthwhile investment.

In summary, the Quadra-Fire QV32EV-B and QV32E-B offer a blend of efficiency, style, and user-friendly technology, making them an exceptional choice for anyone looking to enhance their home's heating system. With their combination of modern design and reliable performance, they are sure to be a centerpiece in any living space.