Quadra-Fire DV400S owner manual High Altitude Installation, Valve Adjustable Regulator

Page 20

R

DV400S DIRECT VENT ROOM HEATER

E. Valve - Adjustable Regulator.

1.Gain access to the Valve Regulator Head by lifting up on the Valve Cover and removing the Tabs from the Slots on the Back Shield.

2.Follow Steps 1 - 3 in the Instructions included with the Regulator. Save the Label included in the Kit for later attachment to the unit.

3.Replace the Valve Cover after the Valve has been checked for leaks.

F. Leak Check.

1.Turn on the Gas Supply to the unit to check for gas leaks with soap and water.

2.Turn the Gas Control Knob to the “Pilot” position.

Push the Knob in all the way and hold. At the same time, push in the Red Ignitor button repeatedly until the Pilot lights. Never hold the Gas Control Knob for more than [10] seconds if the Pilot does not light. Once the Pilot lights, continue to hold the Control Knob in for 15 seconds. Release the Gas Control Knob and it will pop back out. Test for leaks at the Pilot Assembly using a soap and water solution or a a Gas Sniffer. Turn the Gas Control Knob to the “ON” position and turn the Switch On. Check for leaks around the Valve and the Burner Orifice.

3. Plug in blower (if installed).

WARNING!

THE INSTALLATION OF THIS

CONVERSION KIT MUST

ONLY BE UNDERTAKEN BY

A QUALIFIED AND CERTIFIED

GAS APPLIANCE INSTALLER.

NOTE: This Heater DOES NOT require a 110VAC sup- ply for operation.

HIGH ALTITUDE INSTALLATION

For U.S. installation, units are tested and approved for elevations from 0-2000 feet.

When installing this unit at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing Burner Orifice to a smaller size. Input should be reduced 4 percent for each 1000 feet above sea level. Check with the local gas utility for proper Orifice size identification. This unit is shipped with a

.106 in./2.67 mm Main Burner Orifice size for Natural Gas and a

.063 in./1.60 mm orifice size on Propane Gas versions.

For Canadian installation, units are certified for elevations from 0-4500 feet. When installing this unit at an elevation between 0-4500 feet in Canada, the input rating does not need to be reduced.

When installing this unit at an elevation above 4500 feet in Canada, check with local authorities.

Consult your local gas company for assistance in determining the proper Orifice for your location or refer to ANSI Z223.1-latest edi- tion, Appendix F.

NOTE: This Heater must be electrically wired and grounded in accordance with Local Codes or, in the absence of Local Codes, with the National Electric Code ANSI/NFPA 70-latest edition, or the Canadian Electrical Code, CSA C22.1.

NOTE: This appliance and its individual Shut - Off Valve must be disconnected from the Gas Supply Piping System during any Pressure testing of that System at Test Pressures in excess of 1/2 psi (3.5kPa). The appliance must be isolated from the Gas Supply Piping System by closing its individual Manual Shut

-Off Valve during any Pressure testing of the Gas Supply Piping System at test levels equal or less than 1/2 psi (3.5 kPa).

WARNING !

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installatin of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

March 4, 2002

Page 20

30211C

Image 20
Contents DV400S DV400S Direct Vent Room Heater Table of Contents Safety Precautions Listing & Code Approvals SERIAL/RATING LabelTypical Assembly DV400S With Optional BK95Heater System Components Security Chimneys Secure Vent Chimney SystemClearances Horizontal High Wind Cap recommended for optimal performanceTermination Chart a Venting Combinations Horizontal TerminationHorizontal Termination Requirements Preparing the Wall for Horizontal Termination Assembling Venting SectionsDV400S Direct Vent Room Heater Insertion of Vent Pipe DV400S Direct Vent Room Heater Vent Chimney Height Existing Class a Metal Chimney Termination Retro-Fit to Metal Chimney Fuel Conversion GAS Line InstallationGAS Pressure High Altitude Installation Valve Adjustable RegulatorOptional Accessories Optional accessories may be added now or at a later dateBlower Installation Attach On/Off Switch Box for blowerRemote Control Blower Wiring Diagram Optional Wall ThermostatWarming Shelves/Brackets Door TrimCreating the Coal Bed Look. Ember Chunks Log PlacementFirebox Entry Pre-Use Check List For Your Safety Read Before Lighting Lighting InstructionsAIR Shutter Adjustment Allow the unit to cool before replacing the front faceMaintenance Instructions Cleaning the burner and control compartmentCleaning the glass Log cleaningRemote Control Does Not Turn Unit On Off Pilot Will Not LightMain Burners Will Not Start Thermostat Does Not WorkGas Build Up Prevention Feature DV400S Replacement Parts DV400S Gas Log AssemblyThin Layer of Soot Covers the Glass Stove DesignPART# Description Lifetime Warranty Installer

DV400S specifications

The Quadra-Fire DV400S stands as a testament to the evolution of home heating solutions, merging efficiency and innovation in a fireplace insert design. This model is an exemplary choice for homeowners seeking to enhance the comfort of their living spaces while also embracing environmentally conscious heating options.

One of the standout features of the DV400S is its impressive heating capacity. Designed to effectively warm spaces ranging from 800 to 2,000 square feet, this unit ensures an inviting atmosphere even in larger areas. Its powerful yet efficient operation is made possible through advanced combustion technology, which maximizes heat output while minimizing emissions. This feature not only adheres to strict environmental standards but also allows users to enjoy clean-burning, sustainable fuel options.

The DV400S is equipped with a direct vent system, enhancing its versatility. This technology allows the fireplace insert to draw air from outside for combustion, while also venting exhaust gases outside. This ensures that the indoor air quality remains untainted by smoke and particulates, making it a safe option for various home configurations. Additionally, the dual venting options provide installation flexibility, accommodating both horizontal and vertical venting setups.

With a sleek and modern design, the Quadra-Fire DV400S adds aesthetic appeal to any room. Its customizable options for finishes and trim allow homeowners to select the perfect look that complements their décor. The large viewing glass provides an unobstructed view of the fire, creating a cozy ambiance while also featuring an air wash system that keeps the glass clean and clear.

The DV400S is user-friendly, featuring easy-to-use controls for adjusting heat output and flame appearance to suit personal preferences. Its durable construction and high-quality materials ensure longevity and reliability, making it a worthwhile investment for years of enjoyment.

Moreover, this fireplace insert is equipped with innovative safety features, including a dual blower system that circulates warm air throughout the room, and a thermodisc switch that ensures safe operational temperatures. The Quadra-Fire DV400S not only delivers warmth but also offers peace of mind, making it a cornerstone of modern home heating.

In summary, the Quadra-Fire DV400S is a remarkable culmination of efficiency, design, and technology. Its powerful heating capabilities, reliable direct vent system, elegant aesthetics, and user-friendly features make it an excellent choice for those looking to enhance their home heating experience. As a leader in the industry, Quadra-Fire continues to set the standard for quality and innovation in fireplace inserts.