Quadra-Fire DV400S Maintenance Instructions, Cleaning the burner and control compartment

Page 27

R

DV400S DIRECT VENT ROOM HEATER

MAINTENANCE INSTRUCTIONS

Cleaning the burner and control compartment

Keep the burner compartment clean. Brush this area with a clean, dry paint brush and vacuum at least once a year. Always turn off the gas valve and ON/OFF switch before cleaning.

Checking flame patterns

Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. The flame color should be blue with yellow tips. The thermopile tip should be covered with flame. See Figure 26

NOTE: If the air shutter is open all the way and the flames remain sooty, shut off gas to the appliance and contact a qualified gas service technician.

If the vent configuration is installed incorrectly, the vent may cause the flames inside the appliance to lift or “ghost” - a dangerous situation. Inspect the flames after installation to ensure proper perfor- mance. If the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the appliance and contact a qualified service techni- cian. ( See Fig. 27)

Venting system inspection

The heater and venting system should be inspected before use each season, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

Cleaning the glass

It is recommended to wear gloves while handling or removing the glass. DO NOT REMOVE THE GLASS WHEN HOT.

Note: When cleaning the glass, NEVER use abrasive materials. NEVER clean glass when hot.

To clean the glass, use a non-abrasive, mild cleaning solution. (For example, a glass cleaner for stubborn film, or an oven cleaner.) Apply an adequate amount to the glass and wipe off with a damp cloth. Be sure all cleaner is thoroughly rinsed from the glass.

Never operate this heater without the glass properly secured in place or if the glass is broken.

In the event of glass breakage, follow door removal instruc- tions. This will allow the removal of all glass fragments and sheet metal edge protection strips. Vacuum all remaining glass pieces with a shop vac. (DO NOT VACUUM IF PIECES ARE HOT.) Replacement glass can be ordered through your local dealer or distributor. Never use substitute material. Only ceramic glass may be used on this heater.

Log cleaning

Carbon build-up can be removed with a vacuum cleaner.

WARNING!

Do not use this heater if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

 

Ignitor

Thermocouple

Pilot Hood

 

Thermopile

Flame covers top 1⁄2" of the

Thermopile and Thermocouple.

Figure 26 - Standing Pilot

Note: Operation of a Direct Vent Heater may be sporadic in high wind situations.

Correct

Flames should be blue at the base, yellow-orange on the top.

Not Enough Air

If the flames are tall or sooty on the ends, open the air shutter.

Too Much Air

If the flames are all blue, short

and transparent, close the air shutter.

Figure 27 - Flame Patterns

CAUTION: Label all wires prior to disconnec- tion when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

March 4, 2002

Page 27

30211C

Image 27
Contents DV400S DV400S Direct Vent Room Heater Table of Contents Safety Precautions SERIAL/RATING Label Listing & Code ApprovalsDV400S With Optional BK95 Typical AssemblySecurity Chimneys Secure Vent Chimney System Heater System ComponentsHorizontal High Wind Cap recommended for optimal performance ClearancesTermination Horizontal Termination Chart a Venting CombinationsHorizontal Termination Requirements Assembling Venting Sections Preparing the Wall for Horizontal TerminationDV400S Direct Vent Room Heater Insertion of Vent Pipe DV400S Direct Vent Room Heater Vent Chimney Height Existing Class a Metal Chimney Termination Retro-Fit to Metal Chimney GAS Line Installation GAS PressureFuel Conversion Valve Adjustable Regulator High Altitude InstallationAttach On/Off Switch Box for blower Optional AccessoriesOptional accessories may be added now or at a later date Blower InstallationDoor Trim Remote ControlBlower Wiring Diagram Optional Wall Thermostat Warming Shelves/BracketsLog Placement Firebox EntryCreating the Coal Bed Look. Ember Chunks Pre-Use Check List Lighting Instructions For Your Safety Read Before LightingAllow the unit to cool before replacing the front face AIR Shutter AdjustmentLog cleaning Maintenance InstructionsCleaning the burner and control compartment Cleaning the glassThermostat Does Not Work Remote Control Does Not Turn Unit On OffPilot Will Not Light Main Burners Will Not StartStove Design Gas Build Up Prevention FeatureDV400S Replacement Parts DV400S Gas Log Assembly Thin Layer of Soot Covers the GlassPART# Description Lifetime Warranty Installer

DV400S specifications

The Quadra-Fire DV400S stands as a testament to the evolution of home heating solutions, merging efficiency and innovation in a fireplace insert design. This model is an exemplary choice for homeowners seeking to enhance the comfort of their living spaces while also embracing environmentally conscious heating options.

One of the standout features of the DV400S is its impressive heating capacity. Designed to effectively warm spaces ranging from 800 to 2,000 square feet, this unit ensures an inviting atmosphere even in larger areas. Its powerful yet efficient operation is made possible through advanced combustion technology, which maximizes heat output while minimizing emissions. This feature not only adheres to strict environmental standards but also allows users to enjoy clean-burning, sustainable fuel options.

The DV400S is equipped with a direct vent system, enhancing its versatility. This technology allows the fireplace insert to draw air from outside for combustion, while also venting exhaust gases outside. This ensures that the indoor air quality remains untainted by smoke and particulates, making it a safe option for various home configurations. Additionally, the dual venting options provide installation flexibility, accommodating both horizontal and vertical venting setups.

With a sleek and modern design, the Quadra-Fire DV400S adds aesthetic appeal to any room. Its customizable options for finishes and trim allow homeowners to select the perfect look that complements their décor. The large viewing glass provides an unobstructed view of the fire, creating a cozy ambiance while also featuring an air wash system that keeps the glass clean and clear.

The DV400S is user-friendly, featuring easy-to-use controls for adjusting heat output and flame appearance to suit personal preferences. Its durable construction and high-quality materials ensure longevity and reliability, making it a worthwhile investment for years of enjoyment.

Moreover, this fireplace insert is equipped with innovative safety features, including a dual blower system that circulates warm air throughout the room, and a thermodisc switch that ensures safe operational temperatures. The Quadra-Fire DV400S not only delivers warmth but also offers peace of mind, making it a cornerstone of modern home heating.

In summary, the Quadra-Fire DV400S is a remarkable culmination of efficiency, design, and technology. Its powerful heating capabilities, reliable direct vent system, elegant aesthetics, and user-friendly features make it an excellent choice for those looking to enhance their home heating experience. As a leader in the industry, Quadra-Fire continues to set the standard for quality and innovation in fireplace inserts.