FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This gas appliance has a manual ignition device that lights the pilot. When lighting the pilot, follow these instructions exactly.

B.STOP! BEFORE READING FURTHER, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS:

*Do not try to light the appliance.

*Do not touch any electric switch; do not use any telephone in your building.

*Immediately call your gas supplier from a neighbor’s telephone. Follow the instructions of your utility.

*If you cannot reach your utility, call the fire department.

C.IF THE PILOT LIGHT AND BURNER WENT OUT DURING USE, YOU MUST TAKE THE GLASS OFF THE APPLIANCE AND WAIT TO CLEAR OUT ANY GAS. FOLLOW THE LIGHTING INSTRUCTIONS BELOW.

D.Use only your hand to push in or turn the gas control knob to light the pilot. Never use tools. If the knob will not push in or turn by hand, do not try to repair it; call a qualified service technician. Using a tool or attempting repairs may result in a fire or explosion.

E.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appli- ance and to replace any part of the control system and any gas control that has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Turn off all electric power to the appliance. If your appliance has a thermostat, set to lowest setting.

3.Open control access panel.

4.Find the pilot. The pilot is inside the combustion chamber next to the

main burner.

Ignitor

Pilot Hood

Thermocouple

 

Thermopile

7.Smell for gas, including near the floor. If you don’t smell gas, go to the next step. If you smell gas, wait another five (5) minutes or until the gas odor is no longer present before continuing. If the odor of gas does not disappear after fifteen (15) minutes, STOP! Follow “B” in the safety information above.

8.Replace glass panel.

9. Turn gas control knob counterclockwise

to the “PILOT”

position.

 

10.Push the gas control knob in all the way and hold. At the same time, push in red ignition button repeatedly until the pilot lights. Never hold the gas control knob in for more than ten (10) seconds if the pilot does not light. Once the pilot lights, continue to hold the gas control knob in for 15 seconds. Release the gas control knob and it will pop back up. If pilot does not remain lit, repeat steps 6 through 9.

5.If the gas control knob is at the “OFF” position, go to step 7. If the gas control knob is at the “ON” position, go to step 6.

6.If the pilot light went out during normal use with the gas control knob at the “ON” position, turn the gas control knob to the “OFF” position. REMOVE THE FIXED GLASS PANEL. Wait ten (10) minutes to clear out any gas.

*If gas control knob does not pop back up when released, turn the knob to “OFF” and call your service technician or gas supplier.

*If the pilot will not stay on after two attempts, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11. Turn gas control knob counterclockwise to the

“ON” position. The knob can be turned to the “ON” position only if it is popped out.

12.Close the access panel.

13.Turn on electrical power to the appliance. If equipped with a thermostat, set to the desired setting.

TO TURN OFF GAS TO APPLIANCE

1. Turn rocker switch to OFF or the wall thermostat to lowest setting if your

3. Turn gas control clockwise

to “OFF”.

unit is so equipped.

 

 

2. Turn off all electric power to the appliance if service is to be performed.

March 4, 2002

Page 25

30211C

Image 25
Contents DV400S DV400S Direct Vent Room Heater Table of Contents Safety Precautions SERIAL/RATING Label Listing & Code ApprovalsDV400S With Optional BK95 Typical AssemblySecurity Chimneys Secure Vent Chimney System Heater System ComponentsHorizontal High Wind Cap recommended for optimal performance ClearancesTermination Horizontal Termination Chart a Venting CombinationsHorizontal Termination Requirements Assembling Venting Sections Preparing the Wall for Horizontal TerminationDV400S Direct Vent Room Heater Insertion of Vent Pipe DV400S Direct Vent Room Heater Vent Chimney Height Existing Class a Metal Chimney Termination Retro-Fit to Metal Chimney GAS Pressure GAS Line InstallationFuel Conversion Valve Adjustable Regulator High Altitude InstallationOptional accessories may be added now or at a later date Optional AccessoriesBlower Installation Attach On/Off Switch Box for blowerBlower Wiring Diagram Optional Wall Thermostat Remote ControlWarming Shelves/Brackets Door TrimFirebox Entry Log PlacementCreating the Coal Bed Look. Ember Chunks Pre-Use Check List Lighting Instructions For Your Safety Read Before LightingAllow the unit to cool before replacing the front face AIR Shutter AdjustmentCleaning the burner and control compartment Maintenance InstructionsCleaning the glass Log cleaningPilot Will Not Light Remote Control Does Not Turn Unit On OffMain Burners Will Not Start Thermostat Does Not WorkDV400S Replacement Parts DV400S Gas Log Assembly Gas Build Up Prevention FeatureThin Layer of Soot Covers the Glass Stove DesignPART# Description Lifetime Warranty Installer

DV400S specifications

The Quadra-Fire DV400S stands as a testament to the evolution of home heating solutions, merging efficiency and innovation in a fireplace insert design. This model is an exemplary choice for homeowners seeking to enhance the comfort of their living spaces while also embracing environmentally conscious heating options.

One of the standout features of the DV400S is its impressive heating capacity. Designed to effectively warm spaces ranging from 800 to 2,000 square feet, this unit ensures an inviting atmosphere even in larger areas. Its powerful yet efficient operation is made possible through advanced combustion technology, which maximizes heat output while minimizing emissions. This feature not only adheres to strict environmental standards but also allows users to enjoy clean-burning, sustainable fuel options.

The DV400S is equipped with a direct vent system, enhancing its versatility. This technology allows the fireplace insert to draw air from outside for combustion, while also venting exhaust gases outside. This ensures that the indoor air quality remains untainted by smoke and particulates, making it a safe option for various home configurations. Additionally, the dual venting options provide installation flexibility, accommodating both horizontal and vertical venting setups.

With a sleek and modern design, the Quadra-Fire DV400S adds aesthetic appeal to any room. Its customizable options for finishes and trim allow homeowners to select the perfect look that complements their décor. The large viewing glass provides an unobstructed view of the fire, creating a cozy ambiance while also featuring an air wash system that keeps the glass clean and clear.

The DV400S is user-friendly, featuring easy-to-use controls for adjusting heat output and flame appearance to suit personal preferences. Its durable construction and high-quality materials ensure longevity and reliability, making it a worthwhile investment for years of enjoyment.

Moreover, this fireplace insert is equipped with innovative safety features, including a dual blower system that circulates warm air throughout the room, and a thermodisc switch that ensures safe operational temperatures. The Quadra-Fire DV400S not only delivers warmth but also offers peace of mind, making it a cornerstone of modern home heating.

In summary, the Quadra-Fire DV400S is a remarkable culmination of efficiency, design, and technology. Its powerful heating capabilities, reliable direct vent system, elegant aesthetics, and user-friendly features make it an excellent choice for those looking to enhance their home heating experience. As a leader in the industry, Quadra-Fire continues to set the standard for quality and innovation in fireplace inserts.