Master Lock 150000 BTU/Hr, 70000 BTU/Hr, 100000 BTU/Hr owner manual Specifications, Fan

Page 15

Fan

IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.

1.Remove upper shell (see page 10).

2.Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.

3.Slip fan off motor shaft.

4.Clean fan using a soft cloth moistened with kerosene or solvent.

5.Dry fan thoroughly.

6.Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 25).

7.Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds/ 4.5-5.6 n-m).

8.Replace fan guard and upper shell.

SPECIFICATIONS

Setscrew

Fan

Motor

Shaft

Figure 24 - Fan, Motor Shaft, and Setscrew Location

Fan

Flush

Motor

Shaft

Setscrew

Figure 25 - Fan Cross Section

Output Rating (BTU/Hr)

70,000

100,000

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity

 

 

 

(U.S. Gal./Liters)

5.0/18.9

9.0/34.1

13.5/51.1

Fuel Consumption

 

 

 

(Gal. Per Hr./Liters Per Hr.)

.52/1.97

.78/2.95

1.10/4.16

Electric Requirements

220 V/60 Hz (Same All Models)

Amperage (Normal Run)

2.0

2.0

2.0

Hot Air Output (CFM/CMM)

250/7.1

490/13.9

500/14.2

RPM

3450

3450

3450

15

101585

Image 15
Contents Portable Forced AIR Heaters Contents Carbon monoxide poisoning may lead to death Safety Information70,000 BTU/Hr Model Product IdentificationTools Needed Unpacking AssemblyTheory OperationFuels To Start Heater Ventilation OperationOperation Storage Preventative Maintenance Schedule To Stop HeaterTo Restart Heater TROUBLE- Shooting Observed Fault Possible CauseService Procedures Upper Shell RemovalFuel Filter Fuel Filter Removal, 100/150,000 BTU/Hr Models Spark PlugAir Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Burner Head NozzleRotor Location, 70,000 BTU/Hr Model Pump RotorFan Specifications70,000 BTU/Hr Parts BreakdownKEY Part Number Description QTY Parts List100,000 BTU/Hr M10908-2 Screw, #6-32 x 3/8 150,000 BTU/Hr Illustrated Parts BreakdownPart number and description of the desired part Wheels and Handles for Accessories Wiring DiagramsCertificate of General Equipment Limited 90 DAY Warranty Warranty and Repair Service