Samsung SSA-P102T/EXP manual RS-422 Communication Port Connection Multiple Units

Page 17

RS-422 Communication Port Connection (Multiple Units)

The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102.

RxD

TxD

Power

RS-422/232

Converter

T+ T- R+ R-

RS-232C

HOST

MAX. 1200m

TX-

TX+

RX-

RX+

INSTALLATION AND EXTERNAL CONNECTION

SSA-P102

- Follow the guidelines below to make connection between devices.

1.Connect TX(-) of one device to TX(-) of other one.

2.Connect TX(+) of one device to TX(+) of other one.

3.Connect RX(-) of one device to RX(-) of other one.

4.Connect RX(+) of one device to RX(+) of other one.

5.Set a unique board ID for each product.

-Follow the guidelines below to make connection between the terminal device and the RS-422 9-pin connector of the RS-422/RS-232 converter.

1.Connect RS-422-TX(-) to the RX(-) port of the converter.

2.Connect RS-422-TX(+) to the RX(+) port of the converter.

3.Connect RS-422-RX(-) to the TX(-) port of the converter.

4.Connect RS-422-RX(+) to the TX(+) port of the converter.

5.Connect the 9-pin connector of the RS-422/RS-232 converter to the COM port of the computer.

6.Install and launch the application (SAMS).

English _ 17

Image 17
Contents Please visit our website Access Control PanelSafety information Safety informationImportant Safety Instructions Contents Product introduction FeaturesHoliday Setup Door Open Alarm and Forced Door Open AlarmDuress Mode WHAT’S IncludedMain Board Power LED Displays the status of the power supply Buzzer control settingsInput #3 Input #2Cable Selection Termination Resistor Connecting the Termination Resistor and DiodeBypass Diode Connection Termination Resistor in RS-422 CommunicationHost PC EARTH-GROUNDING the Communication CablesPower Connection POWER, READER, and I/O ConnectionCheck the location of the power port Reader ConnectionInput Connection Output Connection RS-232 Communication Port Connection Communication Line ConnectionHost PC GNDHost RS-422 Communication Port Connection StandaloneTX+ RX+ RX+ TX+SSA-P102 RS-422 Communication Port Connection Multiple UnitsTCP/IP Communication Connection TCP/IP Communication Port ConnectionHUB TCP / IP Initializing the system using the Initialize switch Reader Input BIT SetupInitialization System InitializationUse the switch to set the value Board ID SettingCommunication Speed Setup Problem Action TroubleshootingTroubleshooting System is in sync with the PC Service for your helpIrrelevant card number is displayed Product specifications Product SpecificationsCorrect disposal of batteries in this product