IV. MAINTENANCE

IV. MAINTENANCE

1.Inspect and clean lamp at least every 6 months.

2.Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.

V.REPLACEMENT PROCEDURE

VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and disconnect from power source.

1.Remove wire tie or locking mechanism from latch on unit.

2.Unplug ballast plug from end of lamp.

3.Remove the wing nut on securing bracket. Swing out securing bracket to clear lamp.

4.Slide lamp out carefully.

NOTE: When replacing the lamp, always wipe off lamp before installing.

5.Replace lamp following the appropriate procedure based on bracket selection in the installation section.

6.UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste

7.After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation.

8.Replace wire tie or locking mechanism to latch.

VI. TROUBLESHOOTING GUIDE

1.If unit does not light up replace bulb.

2.If unit still does not light up after replacing bulb, replace ballast.

VII. REPLACEMENT PARTS LIST

 

Lamp Length

 

LAMP

BALLAST

 

 

(Field Controls Part Number)

(Field Controls Part Number)

 

 

 

 

12”

46365401

46365506

 

 

 

 

 

18”

46365402

46365506

 

 

 

 

 

28”

46365403

46365506

 

 

 

 

 

For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:

Phone: 252-522-3031

Fax: 252-522-0214

Email: sales@fieldcontrols.com

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.