Field Controls UV-E installation instructions Acces Cover

Models: UV-E

1 8
Download 8 pages 50.98 Kb
Page 3
Image 3
Acces Cover

WARNING: Disconnect electrical power supply before wiring

9.Connect to an appropriate power source such as an AC power disconnect box or to a circuit breaker panel. (See Figure 8)

10.Determine length of wire and conduit necessary according to power connection and install wiring conduit and water tight connector as shown in example figure 4. (Supplied by installer.)

11.Remove wiring access cover to expose terminal block. (Figure 5)

Acces Cover

Figure 4

Figure 5

 

12.Push power source wires through bushing in access cover then begin securing wires according to the wiring diagram in figure 8. (See Figures 6 & 7)

Figure 7

Figure 6

13.Replace access cover.

14.Group wires together and tuck in wire clip on right side of box. (See Figure 9)

Wire Clip

Figure 9

Figure 8

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.