I.GENERAL INFORMATION
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.
| Minimum |
|
|
|
| Max Air |
|
|
|
|
| ||
Lamp Length | Duct | Volts | Amps | Hz | Watts | Temp |
| Width |
|
|
|
| °F |
12” | 9 | 120/240 | 0.5 | 60 | 30 | 150° |
|
|
|
|
|
|
|
18” | 14 | 120/240 | 0.5 | 60 | 30 | 150° |
|
|
|
|
|
|
|
28” | 22 | 120/240 | 1.1 | 60 | 60 | 150° |
|
|
|
|
|
|
|
Lamp Intensity at 1
meter
37μW/cm2
73μW/cm2 105 μW/cm2
Recommended
Max Sq. Feet
1500
2000
3000
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source.
II.INSTALLATION
1. Determine a suitable location on either the supply or return for the unit as shown in Figure 1. The unit must be mounted at least 3 feet from any flex duct type material.
NOTE: Unit can only be mounted in a vertical position as noted on inside cover label.
2. Apply mounting template to air duct as shown in Figure 2.
3. Drill 1/8” diameter mounting holes at positions indicated on template. (See Figure 2)
4.Using a 2” hole saw, drill out lamp hole as shown on template. (See Figure 2)
5. Drill a 7/8” inspection hole as shown on template. (See Figure 2)
6. Remove template.
Figure 1
7.Mount unit to duct using the 4 supplied sheet metal screws. (See Figure 3)
Figure 2
Figure 3
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the