QSDL503AD USER MANUAL
Section 7: TURNING YOUR SYSTEM ON
1.Once you have configured your Main Control Unit and your Magnetic Code Controller, you can now use your alarm system. With the power to your Main Control Unit on, press the ARM button on the Magnetic Code Controller (Picture 8). You will hear the Main Control Unit and the Wireless Indoor Lighted Siren respond by beeping to let you know that they are on and armed. You will also see the message “SAVE” displayed on the display screen of your Main Control Unit.
2.Your system is now on and after 30 seconds, you can no longer enter through any protected windows or entry ways without triggering the system’s alarm. Entry through any of the doorways or windows being protected will constitute a breach of security and your system will immediately respond by emitting a high pitched alarm from the Wireless Indoor Lighted Siren and automatically dialing out to the stored telephone numbers.
3.Pressing the “ALARM” button on your Main Control Unit should be used in the event of an emergency as it also constitutes a breach of security and will trigger all the alarms on your system instantaneously. The Wireless Indoor Siren will respond with a high pitched alarm and your Main Control Unit will automatically dial out to all stored numbers in the event the “ALARM” button is pushed.
4.Entering your 4 digit Access Code in the Magnetic Code Controller will disarm the system and allow you to enter without triggering the system.
5.It is time to replace the batteries in your Wireless Indoor Siren when the LED light on the front flashes in 5 second intervals. Your Infrared Sensor will notify you that it is time to change the batteries when the LED light on the front is yellow.