Procom ML150HPA, ML150TPA Operating Your Heater, Shutting Off Burner Only pilot, Stays lit

Page 12

OPERATING YOUR HEATER

THERMOSTAT MODELS

 

 

 

 

 

nLIGHTINGn

 

 

 

 

 

a qualified service person or gas

 

 

 

 

INSTRUCTIONS

 

 

 

 

 

supplier

for

repairs.

 

 

 

nFOR YOUR SAFETYn

1.

STOP!

 

Read

 

the

safety

 

Note: If pilot goes out, repeat

 

 

 

 

steps 3

through 7. This

heater

 

READ BEFORE LIGHTING

2.

information on the side of heater.

 

has

a

safety

interlock system.

 

 

 

 

 

 

 

 

 

 

 

 

 

Make

sure

equipment

shutoff

 

Wait one(1)minute before lighting

 

WARNING:

If

you

do

not

 

valve

is fully

open.

 

 

 

 

 

 

 

3.

 

 

 

 

 

 

pilot

again.

 

 

 

 

 

follow these instructions exactly, a

Turn

control

knob clockwise

 

 

8.

Turn control knob counterclock-

fire

or

explosion

may

 

result

 

to the

OFF

position.

 

 

 

 

 

 

 

 

 

 

 

wise

 

to desired heating level.

causing property damage,personal

4.

Wait

 

five(5)

minutes to

clear

 

 

 

 

The main burner should light.

injury or

loss

of

life.

 

 

 

 

 

 

out any gas. Then smell for gas,

 

 

 

 

 

 

 

 

Set control knob to any heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

including

near the floor. If you

 

A. When lighting the pilot, follow these

 

 

level between HI and LO.(see

 

smell gas, STOP! Follow “B” in the

 

 

 

Figure 20)

 

 

 

 

 

instructions exactly.

 

 

 

 

 

 

 

 

safety information on the side

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Do not try to ad-

B.

BEFORE

LIGHTING

smell all

 

heater.

If

 

you

don’t

smell

 

 

around the

appliance area

for

gas.

 

gas, go to the next

step.

 

 

 

just heating levels by using

the

 

 

 

 

equipment shutoff valve.

 

 

Be

sure

to

smell

next

 

to

the

floor

5.

Turn

control

knob counterclock-

 

 

 

 

 

 

 

 

 

 

 

 

 

because

some gas

is

heavier

than

 

wise

 

 

to the PILOT position.

 

 

 

 

 

 

 

 

 

 

 

Press in

 

control

knob

for

 

 

 

 

 

 

 

 

 

 

air

and will settle on

the

floor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

five(5) seconds. (see Figure 20).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT TO DO IF YOU SMELL GAS

 

Note: You

 

may

be

running

 

 

 

 

 

 

 

 

 

 

 

this heater for the first time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do

not

try

to

light

any

 

after hooking

up to

gas supply.

 

 

 

 

 

 

 

 

 

 

 

If

so,

the control

knob

may

 

 

 

 

 

 

 

 

 

 

 

appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

need

 

to

be

pressed in for

30

Figure 20 - Control Knob in The

Do

not

touch

any

 

electric

 

 

 

 

seconds. This will allow air to

OFF Position

 

 

 

 

 

 

switch,

do

not

use any

phone

 

bleed from the gas system.

 

 

 

 

 

 

 

 

 

 

 

 

 

in your building.

 

 

 

 

 

 

If control knob does

not pop

 

 

 

 

 

 

 

 

 

 

Immediately

call

 

your

gas

 

up when released, contact a

 

 

 

 

 

 

 

 

 

 

 

supplier

from

a

 

neighbor’s

 

qualified

service

person

 

or

 

 

 

 

 

 

 

 

 

 

 

phone. Follow the gas

 

gas

supplier

for

repairs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

With

 

control

knob pressed

 

in,

 

 

 

 

 

 

 

 

 

 

 

supplier’s

instructions.

 

 

 

push

down

and

release ignitor

 

 

 

 

 

 

 

 

 

 

If

you

cannot

reach

your gas

 

 

 

 

 

 

 

 

 

 

 

 

button. This

will

light pilot. The

 

 

 

 

 

 

 

 

 

 

 

supplier,

call

 

the

 

fire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pilot

is attached

to

the

front

 

of

 

 

 

 

 

 

 

 

 

 

 

department.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

burner. If

needed, keep pressing

 

 

 

 

 

 

 

 

 

 

C.

Use

only

your

hand to

push in

 

Figure 21 - Pilot

 

 

 

 

 

ignitor button until pilot lights.

 

 

 

 

or turn the gas control knob.

Note: If

pilot does not stay

lit, refer

 

 

nTO TURN OFFn

 

 

Never use tools. If the knob will

to Troubleshooting, pages 14 through

 

 

 

 

not push in or turn by hand, don’t

16. Also contact a qualified service

 

GAS TO APPLIANCE

 

try

to

repair

it , call

 

a

qualified

person

or

gas

supplier

for

repairs.

Shutting

Off Heater

 

 

service technician or gas supplier.

Until repairs are made, light pilot with

1.

Turn

control

knob clockwise

Force

or

attempted

 

repair

may

match.To light pilot with match, see

2.

to the OFF position.

to the

result

in

a

fire

or

explosion.

 

 

Manual Lighting Procedure.

 

 

 

 

Turn

off

all

electric power

 

 

7.

Keep

control

knob

pressed

 

appliance

if

 

service

is

to

D.

Do

not use

this

 

appliance if

 

 

 

 

be performed.

 

 

 

 

any part

has

been under

water.

 

in

for

30 seconds after lighting

 

 

 

 

 

 

pilot. After 30 seconds,

release

Shutting

Off Burner Only (pilot

Immediately call a

qualified

service

 

 

control

knob.

 

 

 

 

 

 

 

 

stays lit )

 

 

 

 

 

 

technic ian

to

 

inspect

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If

control knob does not pop

Turn control knob clockwise

 

to

appliance and to replace any part of

 

up

when

released, contact

the PILOT position.

 

 

 

 

the control system and any gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control which has been

under

water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 22 - Burner Patterns

12

Image 12
Contents OWNER’S Operation and Installation Manual ML150HPA ML150TPA ML250HPA ML250TPASafety Information Important Read thisProduct Features Fresh AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceVentilation AIR Ventilation Air from Inside BuildingInstallation Installation NeedsVentilation AIR Locating HeaterInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching to Wall Anchor MethodPlacing Heater on Mounting Bracket Connecting to GAS Supply Important InstallTypical Inlet Pipe Diameters NPTNFOR Your SAFETYn Checking GAS ConnectionsNON-THERMOSTAT Models Read Before LightingOperating Your Heater Shutting Off HeaterShutting Off Burner Only pilot stays lit Operating Your Heater Shutting Off Burner Only pilotStays lit Cleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Inlet HoleOperating Heater Main TenanceTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Page 13 or Observed Problem Possible Cause RemedySpecifications Parts Under WarrantyML150HPA ML250TPABurner Assembly ODS/Pilot Assembly Illustrated Parts BreakdownML150HPA Parts List ML150HPA KEY ML150HPA NO. Part noDescription QTY ODSODS/Pilot Assembly Burner Assembly Parts List ML250HPA KEY ML250HPA Description QTYNRV81FIL-10 ML150TPA Parts List ML150TPA KEYML250TPA Parts List ML250TPA KEY ML250TPA

ML150TPA, ML250HPA, ML150HPA specifications

The Procom ML250HPA, ML150HPA, and ML150TPA represent the pinnacle of high-performance heating systems, tailored to meet diverse heating needs with efficiency and reliability. These models are known for their innovative technologies and robust characteristics, making them ideal choices for both residential and commercial applications.

The ML250HPA stands out with its impressive heating capacity, perfect for larger spaces. It incorporates advanced features for user convenience, including a fully programmable thermostat and remote control functionality. This model utilizes high-efficiency heating elements that not only provide powerful warmth but also help to keep energy consumption low. The integration of smart technology allows for real-time monitoring and adjustments, ensuring optimal comfort while minimizing energy use.

On the other hand, the ML150HPA is designed for medium-sized spaces, offering a balance of performance and efficiency. Like its bigger counterpart, it showcases energy-efficient heating elements. The model is equipped with built-in safety features such as overheat protection and tip-over switches, ensuring peace of mind during operation. Its compact design allows for versatile installation options, while the stylish finish makes it an attractive addition to any room.

The ML150TPA variant focuses on portability without sacrificing performance. This model is lightweight, making it easy to move from one location to another while still providing powerful heating capabilities. It features an adjustable heat output, allowing users to customize the temperature according to their immediate needs. The robust construction ensures durability, making it suitable for various environments, from workshops to temporary living spaces.

All three models emphasize energy efficiency and low operating costs, incorporating eco-friendly technologies that align with modern energy standards. The intelligent design of these units helps to reduce noise levels, providing a peaceful environment without disruptive sounds common in traditional heating systems.

In summary, the Procom ML250HPA, ML150HPA, and ML150TPA are exceptional heating solutions that cater to different requirements while ensuring energy-efficient and reliable performance. Their combination of advanced features, safety mechanisms, and user-friendly interfaces make them a smart investment for anyone looking to enhance their heating experience. Whether you prioritize capacity, portability, or a balance of both, Procom has a model designed to meet your specific needs.