Procom ML250HPA, ML150HPA Attaching to Wall Anchor Method, Placing Heater on Mounting Bracket

Page 8

Attaching Mounting Bracket to Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to Wal l Stud Method For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid

walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9 below.

Figure 9 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall

anchor. Push red key to "pop" open anchor wings (see Figure 10).

INSTALLATION

IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 10 - Popping Open Anchor Wing For Thin Walls

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater on Mounting Bracket

1.Locate two horizontal slots on back panel of heater (see Figure 11).

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Figure 11 - Mounting Heater Onto Mounting Bracket

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater(see Figure 12).

Figure 12 - Installing Bottom Mounting Screws

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors.Follow steps

1through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw

into wall stud, drill holes at marked locations using 9/64" drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled holes.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled holes .

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace lower front panel at this time. Replace lower front panel after making gas connections and checking for leaks (see pages 9 and 10).

8

Image 8
Contents OWNER’S Operation and Installation Manual ML150HPA ML150TPA ML250HPA ML250TPASafety Information Important Read thisProduct Features Fresh AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceVentilation AIR Ventilation Air from Inside BuildingInstallation Installation NeedsVentilation AIR Locating HeaterInstallation Installing Thermostat Sensing BulbPlacing Heater on Mounting Bracket Installing Bottom Mounting ScrewsAttaching to Wall Anchor Method Connecting to GAS Supply Important InstallTypical Inlet Pipe Diameters NPTNFOR Your SAFETYn Checking GAS ConnectionsNON-THERMOSTAT Models Read Before LightingShutting Off Burner Only pilot stays lit Operating Your HeaterShutting Off Heater Stays lit Operating Your HeaterShutting Off Burner Only pilot Cleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Inlet HoleOperating Heater Main TenanceTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Page 13 or Observed Problem Possible Cause RemedySpecifications Parts Under WarrantyML150HPA ML250TPAML150HPA Burner Assembly ODS/Pilot AssemblyIllustrated Parts Breakdown Parts List ML150HPA KEY ML150HPA NO. Part noDescription QTY ODSODS/Pilot Assembly Burner Assembly NRV81FIL-10 Parts List ML250HPAKEY ML250HPA Description QTY ML150TPA Parts List ML150TPA KEYML250TPA Parts List ML250TPA KEY ML250TPA

ML150TPA, ML250HPA, ML150HPA specifications

The Procom ML250HPA, ML150HPA, and ML150TPA represent the pinnacle of high-performance heating systems, tailored to meet diverse heating needs with efficiency and reliability. These models are known for their innovative technologies and robust characteristics, making them ideal choices for both residential and commercial applications.

The ML250HPA stands out with its impressive heating capacity, perfect for larger spaces. It incorporates advanced features for user convenience, including a fully programmable thermostat and remote control functionality. This model utilizes high-efficiency heating elements that not only provide powerful warmth but also help to keep energy consumption low. The integration of smart technology allows for real-time monitoring and adjustments, ensuring optimal comfort while minimizing energy use.

On the other hand, the ML150HPA is designed for medium-sized spaces, offering a balance of performance and efficiency. Like its bigger counterpart, it showcases energy-efficient heating elements. The model is equipped with built-in safety features such as overheat protection and tip-over switches, ensuring peace of mind during operation. Its compact design allows for versatile installation options, while the stylish finish makes it an attractive addition to any room.

The ML150TPA variant focuses on portability without sacrificing performance. This model is lightweight, making it easy to move from one location to another while still providing powerful heating capabilities. It features an adjustable heat output, allowing users to customize the temperature according to their immediate needs. The robust construction ensures durability, making it suitable for various environments, from workshops to temporary living spaces.

All three models emphasize energy efficiency and low operating costs, incorporating eco-friendly technologies that align with modern energy standards. The intelligent design of these units helps to reduce noise levels, providing a peaceful environment without disruptive sounds common in traditional heating systems.

In summary, the Procom ML250HPA, ML150HPA, and ML150TPA are exceptional heating solutions that cater to different requirements while ensuring energy-efficient and reliable performance. Their combination of advanced features, safety mechanisms, and user-friendly interfaces make them a smart investment for anyone looking to enhance their heating experience. Whether you prioritize capacity, portability, or a balance of both, Procom has a model designed to meet your specific needs.