CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

CAUTION: Never connect heat er direct ly to t he propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure . You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Figure 13 - External Regulator with Vent Pointing Down

WARING:Do not over tighten gas connections.

INSTALLATION

r

Figure 14 -Gas Connection

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories, page 17.

CAUTION: Use only new, black

Apply

pipe joint

sealant lightly to

male

threads.

 

This

will

prevent

iron or steel

pipe. Internally-tinned

 

 

 

excess sealant

from

going

into

copper tubing

may

be

used in

 

 

pipe. Excess sealant

in

pipe

could

certain areas. Check your local

 

 

result

in clogged

heater

valves.

codes. Use pipe of large

enough

 

diameter to allow proper gas volume

 

CAUTION: Use

pipe

joint

to heater. If

pipe is too

small,

 

sealant

that

 

is resistant

to

undue loss of pressure will occur.

 

 

 

liquid

petroleum (LP)

gas.

 

 

 

 

 

 

 

 

 

 

 

 

Typical Inlet Pipe Diameters

 

 

Install sediment trap in supply line

All models up to 20,000 BTU’s use

as shown

in

Figure 14.

Locate

3/8’’ or greater pipe;

 

 

 

 

sediment trap where it is within

All models 25,000 BTU’s and higher,

use 1/2” or greater pipe.

 

 

 

reach

for

cleaning.

Locate

 

 

 

sediment

trap

where

trapped

Installation

 

must

include

an

 

matter is not likely to freeze. A

equipment

shutoff

valve,

union,

sediment

trap

traps

moisture and

and plugged 1/8" NPT tap. Locate

contaminants.

This

keeps

them

NPT tap within

reach

for

test gauge

from going into heater controls. If

hook

up.

 

NPT

tap

must

be

sediment trap is not installed

or is

upstream from heater(see Figure 14).

installed

wrong,

heater

may

IMPORTANT: Install

an

equipment

not run properly.

 

 

 

 

 

shutoff valve in an accessible

IMPORTANT:

 

Hold

pressure

location. The

equipment

shutoff

regulator

with

wrench

when

valve

is for

turning

on

or

shutting

connecting it to gas piping and/or

off the

gas

to

the appliance.

 

fittings.

 

 

 

 

 

 

 

9

Image 9
Contents ML150HPA ML150TPA ML250HPA ML250TPA OWNER’S Operation and Installation ManualImportant Read this Safety InformationProduct Features Providing Adequate Ventilation Fresh AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceVentilation Air from Inside Building Ventilation AIRInstallation Needs InstallationVentilation AIR Locating HeaterInstalling Thermostat Sensing Bulb InstallationInstalling Bottom Mounting Screws Attaching to Wall Anchor MethodPlacing Heater on Mounting Bracket Important Install Connecting to GAS SupplyTypical Inlet Pipe Diameters NPTChecking GAS Connections NFOR Your SAFETYnNON-THERMOSTAT Models Read Before LightingOperating Your Heater Shutting Off HeaterShutting Off Burner Only pilot stays lit Operating Your Heater Shutting Off Burner Only pilotStays lit Cleaning Burner Pilot AIR Inlet Hole Cleaning ODS/PILOT and BurnerOperating Heater Main TenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Page 13 or Possible Cause Remedy Observed ProblemParts Under Warranty SpecificationsML150HPA ML250TPABurner Assembly ODS/Pilot Assembly Illustrated Parts BreakdownML150HPA KEY ML150HPA NO. Part no Parts List ML150HPADescription QTY ODSODS/Pilot Assembly Burner Assembly Parts List ML250HPA KEY ML250HPA Description QTYNRV81FIL-10 ML150TPA KEY Parts List ML150TPAML250TPA KEY ML250TPA Parts List ML250TPA

ML150TPA, ML250HPA, ML150HPA specifications

The Procom ML250HPA, ML150HPA, and ML150TPA represent the pinnacle of high-performance heating systems, tailored to meet diverse heating needs with efficiency and reliability. These models are known for their innovative technologies and robust characteristics, making them ideal choices for both residential and commercial applications.

The ML250HPA stands out with its impressive heating capacity, perfect for larger spaces. It incorporates advanced features for user convenience, including a fully programmable thermostat and remote control functionality. This model utilizes high-efficiency heating elements that not only provide powerful warmth but also help to keep energy consumption low. The integration of smart technology allows for real-time monitoring and adjustments, ensuring optimal comfort while minimizing energy use.

On the other hand, the ML150HPA is designed for medium-sized spaces, offering a balance of performance and efficiency. Like its bigger counterpart, it showcases energy-efficient heating elements. The model is equipped with built-in safety features such as overheat protection and tip-over switches, ensuring peace of mind during operation. Its compact design allows for versatile installation options, while the stylish finish makes it an attractive addition to any room.

The ML150TPA variant focuses on portability without sacrificing performance. This model is lightweight, making it easy to move from one location to another while still providing powerful heating capabilities. It features an adjustable heat output, allowing users to customize the temperature according to their immediate needs. The robust construction ensures durability, making it suitable for various environments, from workshops to temporary living spaces.

All three models emphasize energy efficiency and low operating costs, incorporating eco-friendly technologies that align with modern energy standards. The intelligent design of these units helps to reduce noise levels, providing a peaceful environment without disruptive sounds common in traditional heating systems.

In summary, the Procom ML250HPA, ML150HPA, and ML150TPA are exceptional heating solutions that cater to different requirements while ensuring energy-efficient and reliable performance. Their combination of advanced features, safety mechanisms, and user-friendly interfaces make them a smart investment for anyone looking to enhance their heating experience. Whether you prioritize capacity, portability, or a balance of both, Procom has a model designed to meet your specific needs.