VENTILATION AIR

Figure 3 -Ventilation Air from Outdoors

INSTALLATION

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.

Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has

athermostat-controlled power vent. Heated air entering the attic will activate the power vent.

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only Propane/LP gas. If your gas supply is not Propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION NEEDS

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to Propane/LP gas)

equipment shutoff valve*

ground joint union

test gauge connection*

sediment trap

tee joint

pipe wrench

*A CSA/AGA design-certified equip-ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design certified equipment shutoff valve from your dealer. See Accessories, page 17.

LOCATING HEATER

This heater is designed to be mounted on a wall. You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 17.

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 17. If planning to use fan, locate heater near an electrical outlet.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor.

locate heater where moving vehicle will not hit it.

 

CAUTION:

This

heater

creates

warm air

currents.

These

currents

move

heat

to wall

surfaces

next

to

heat er .

Ins t alling

heat er

next

to

vinyl

or

 

cloth

wall

c o v e ri ngs

or

 

ope ra t i ng

heater

where impurities

(such as

tobacco smoke, aromatic

candles,

cleaning

fluids, oil or kerosene

lamps, etc.) in the air exist may discolor walls.

WARNING: Never install the heater

in a bedroom or bathroom.

in a recreational vehicle.

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater.

as a fireplace insert.

in high traffic areas.

in windy or drafty areas.

6

Image 6
Contents OWNER’S Operation and Installation Manual ML150HPA ML150TPA ML250HPA ML250TPASafety Information Important Read thisProduct Features Determining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationProviding Adequate Ventilation Determining if you have a Confined or Unconfined SpaceVentilation AIR Ventilation Air from Inside BuildingVentilation AIR InstallationInstallation Needs Locating HeaterInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching to Wall Anchor MethodPlacing Heater on Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyImportant Install NPTNON-THERMOSTAT Models NFOR Your SAFETYnChecking GAS Connections Read Before LightingOperating Your Heater Shutting Off HeaterShutting Off Burner Only pilot stays lit Operating Your Heater Shutting Off Burner Only pilotStays lit Operating Heater Cleaning ODS/PILOT and BurnerCleaning Burner Pilot AIR Inlet Hole Main TenanceTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Page 13 or Observed Problem Possible Cause RemedyML150HPA SpecificationsParts Under Warranty ML250TPABurner Assembly ODS/Pilot Assembly Illustrated Parts BreakdownML150HPA Description QTY Parts List ML150HPAKEY ML150HPA NO. Part no ODSODS/Pilot Assembly Burner Assembly Parts List ML250HPA KEY ML250HPA Description QTYNRV81FIL-10 ML150TPA Parts List ML150TPA KEYML250TPA Parts List ML250TPA KEY ML250TPA

ML150TPA, ML250HPA, ML150HPA specifications

The Procom ML250HPA, ML150HPA, and ML150TPA represent the pinnacle of high-performance heating systems, tailored to meet diverse heating needs with efficiency and reliability. These models are known for their innovative technologies and robust characteristics, making them ideal choices for both residential and commercial applications.

The ML250HPA stands out with its impressive heating capacity, perfect for larger spaces. It incorporates advanced features for user convenience, including a fully programmable thermostat and remote control functionality. This model utilizes high-efficiency heating elements that not only provide powerful warmth but also help to keep energy consumption low. The integration of smart technology allows for real-time monitoring and adjustments, ensuring optimal comfort while minimizing energy use.

On the other hand, the ML150HPA is designed for medium-sized spaces, offering a balance of performance and efficiency. Like its bigger counterpart, it showcases energy-efficient heating elements. The model is equipped with built-in safety features such as overheat protection and tip-over switches, ensuring peace of mind during operation. Its compact design allows for versatile installation options, while the stylish finish makes it an attractive addition to any room.

The ML150TPA variant focuses on portability without sacrificing performance. This model is lightweight, making it easy to move from one location to another while still providing powerful heating capabilities. It features an adjustable heat output, allowing users to customize the temperature according to their immediate needs. The robust construction ensures durability, making it suitable for various environments, from workshops to temporary living spaces.

All three models emphasize energy efficiency and low operating costs, incorporating eco-friendly technologies that align with modern energy standards. The intelligent design of these units helps to reduce noise levels, providing a peaceful environment without disruptive sounds common in traditional heating systems.

In summary, the Procom ML250HPA, ML150HPA, and ML150TPA are exceptional heating solutions that cater to different requirements while ensuring energy-efficient and reliable performance. Their combination of advanced features, safety mechanisms, and user-friendly interfaces make them a smart investment for anyone looking to enhance their heating experience. Whether you prioritize capacity, portability, or a balance of both, Procom has a model designed to meet your specific needs.