Procom SN250TYLA-D, SL250TYLA-D installation manual Cleaning and Maintenance

Page 11

CLEANING AND MAINTENANCE

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control

areas, burner, and circulating air pas- sageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING ODS/IGNITOR AND BURNER

Clean with a vacuum cleaner.

CLEANING MAIN AIR INLET HOLE

We recommend that you clean the unit every three months or after 2500 hours of operation. We also recom- mend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see figure 17).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have been pushed into the burner, repeat steps

3and 4.

Clean the pilot assembly also. A y e l l o w t i p o n t h e p i l o t f l a m e indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 18). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Figure 18-Pilot Air Inlet Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

EXTERIOR

Use a soft cloth dampened with a mild soap and water mixture. Wipe t h e c a b i n e t t o r e m o v e d u s t .

LOGS

If you remove logs for cleaning, refer to Installing Logs , page 15, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be o p e n w i t h a s m a l l b l u e f l a m e present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

11

Image 11
Contents SN250TYLA-D SL250TYLA-D OWNER’S Operation and Installation ManualP O R TA N T R e a d Safety Information WarningsUnpacking Safety InformationProduct Features Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationVentilation Air From Outdoors Check GAS Type InstallationConnecting to GAS Supply InstallationChecking GAS Connections Pressure Testing Heater Gas ConnectionsLighting Instructions Installing LogsFor Your Safety Read Before Lighting Operating HeaterInspecting Burners Manual Lighting ProcedureOperating Heater Thermostat Control OperationCleaning and Maintenance Remedy TroubleshootingObserved Problem Possible CauseRemedy SpecificationsObserved Problem Possible Cause SL250TYLA-D SN250TYLA-DEquipment Shutoff Valve Replacement PartsReplacement Parts Accessories Parts Under WarrantyInstall legs and flex tube Illustrated Parts Breakdown PA RT S C RIP Tion QTY Numb E R Parts ListIllustrated Parts Breakdown Part Description QTY Number SN250TYLA-D SL250TYLA-D C E S S O R Y M O D E L NFHTX186 Installing Blower Accessory Blower Accessory Model NFHTX186Side View Installing Blower Accessory Blower Accessory Model NFHTX186

SL250TYLA-D, SN250TYLA-D specifications

The Procom SL250TYLA-D and SN250TYLA-D are advanced communication solutions designed for professional users who demand reliable and efficient performance in challenging environments. Both models combine cutting-edge technology with robust features, making them ideal for various applications, including public safety, event management, and business communication.

The SL250TYLA-D is particularly known for its standout audio clarity, which ensures that users can communicate seamlessly even in noisy conditions. It boasts a powerful speaker that provides crisp and clear sound, allowing users to stay connected without needing to raise their voice. This robust audio system also incorporates noise-cancellation technology, which filters out unwanted background sounds, enhancing the clarity of communication.

The device features a user-friendly interface, with a large LCD display that provides essential information at a glance. Users can easily navigate through menus and settings, making adjustments on the go. The durable design of the SL250TYLA-D ensures it can withstand the rigors of daily use, with an IP67 rating that makes it resistant to dust and capable of withstanding immersion in water. This durability is complemented by an extended battery life, allowing for all-day use without the need for frequent recharging.

On the other hand, the SN250TYLA-D is specifically designed for versatile communication. It supports multiple frequency bands, allowing it to be used in various communication scenarios, whether in urban settings or remote areas. The device is equipped with digital encryption features, ensuring secure communications that protect sensitive information from eavesdropping or interception.

In terms of connectivity, both models support Bluetooth functionality, allowing users to connect to headsets and other devices, enhancing hands-free communication. They also feature a variety of programmable buttons that can be customized to suit the user's needs, enabling quick access to frequently used functions.

Another significant characteristic of the SL250TYLA-D and SN250TYLA-D is their compatibility with other Procom accessories, such as external antennas and chargers, allowing for a customizable communication setup. These models are designed for ease of use, making them an excellent choice for teams that need reliable and immediate communication in dynamic environments.

Overall, the Procom SL250TYLA-D and SN250TYLA-D stand out for their exceptional audio quality, durable design, advanced security features, and user-friendly interfaces. They represent a solid investment for organizations that prioritize effective communication and operational efficiency in their daily operations.