Marley Engineered Products D Example Clearances, Installation of Single Unit, CM3

Page 2

IMPORTANT !

CAUTION !

CERTAIN FABRICS DISCOLOR IN TIME FROM INDIRECT SUNLIGHT AND NORMAL ROOM TEMPERATURE - MOSTLY ORGANIC AND SYNTHETIC MATERIAL. THEY WILL DISCOLOR MORE RAPIDLY WHEN EXPOSED TO DIRECT SUNLIGHT AND WARM CURRENTS. HANG DRAPES TO PROVIDE MINIMUM OF 2 INCHES (51mm) AIR SPACE BETWEEN HEATER FRONT

CAUTION !

HEATER MAY BE INSTALLED ABOVE THE FLOOR SUCH AS ATOP A BASE- BOARD. HOWEVER, THE POWER SUPPLY MUST ENTER THE HEATER THROUGH THE KNOCKOUT IN THE BACK OF THE HEATER IF INSTALLED ABOVE THE FLOOR.

AND NEAREST DRAPE FOLD AS SHOWN IN EXAMPLE 1, FIGURE 1, OR 6 INCHES (152mm) AIR SPACE BETWEEN TOP OF HEATER AND BOTTOM

OF DRAPES AS SHOWN IN EXAMPLE 2, FIGURE 1. ALLOW MINIMUM CLEARANCE OF 1 INCH (25mm) FROM DRAPES TO CEILING AND TO TOP

OF FLOOR COVERING TO PERMIT AIR CIRCULATION.

CAUTION !

TO PREVENT POSSIBLE DAMAGE TO INTERNAL HEATER WIRING, ALL DRILLING OF END CAPS MUST BE DONE WITH END CAPS REMOVED FROM HEATER.

CEILING

1" (25mm) CLEARANCE (MIN)

DRAPERY

EXAMPLE 1

CEILING

1" (25mm) CLEARANCE (MIN)

DRAPERY

EXAMPLE 2

CLEARANCES

FLOORS & CARPETING: HEATERS MAY BE MOUNTED DIRECTLY ON ANY FLOOR SURFACE, INCLUDING CARPETING. WHERE WALL-TO-WALL CAR-

PETS ARE INSTALLED AFTER THE BASEBOARD INSTALLATION, THE CAR- PETING CAN BE RUN UP TO THE FRONT AND AROUND THE HEATER BODY.

FULL LENGTH DRAPES: FOR THE MOST SATISFACTORY OPERATION OF HEATERS, THE FOLLOWING CLEARANCES MUST BE MAINTAINED:

1.HANG DRAPES SO THAT, IN USE, THEY EXTEND BELOW THE CENTER LINE OF THE HEATER, BUT WITH AT LEAST 1” (25mm) CLEARANCE FROM THE TOP OF THE FINISHED FLOOR COVERING, SUCH AS CARPET, TILE, ETC.

2.HANG DRAPES SO THERE IS AT LEAST 2” (51mm) BETWEEN THE EXTREME FRONT OF THE HEATER AND THE NEAREST FOLD OF DRAPES, IN THE FOLDED BACK POSITION (OPEN DRAPE POSITION).

3.HANG DRAPES SO THERE IS AT LEAST 1” (25mm) BETWEEN THE TOP OF THE DRAPES AND THE CEILING.

SHORT DRAPES: HANG DRAPES SO THERE IS AT LEAST 6” (152mm) CLEAR-

ANCE ABOVE THE TOP OF THE HEATER.

FURNITURE: DO NOT PLACE FURNITURE AGAINST HEATER. IT IS RECOM- MENDED ALL ITEMS BE KEPT A MINIMUM OF 6” (152mm) FROM HEATER.

INSTALLATION OF SINGLE UNIT

Liquid filled baseboard heaters are designed for installation in new or existing con- struction. In existing construction, baseboard molding should be removed and the heaters mounted flush against the wall surface. When replacing molding allow 1/16” (1 mm) clearance between molding and ends of heaters.

NOTE: This heater can be wired in either the right or left hand junction box. See Table 1 for wiring compartment volumes.

Table 1. Field Wiring Compartment Volumes

 

Est. Net Total Volume

 

 

 

Description

CM3

In3

Heater Wiring Compartment (One End)

200

13.25

 

 

 

Heater Wiring Compartment with

 

 

T1 or T2 Thermostat Accessory

175

11.25

 

 

 

Accessory Blank Section (No Controls)

2400

145

 

 

 

AC Accessory Section

2300

140

 

 

 

DR Accessory Section

2300

140

 

 

 

CDS2 Accessory Section

2300

140

 

 

 

LVR Accessory Section

2100

130

 

 

 

WALL

 

WALL

6" (152mm) CLEARANCE

 

2" (51mm) CLEARANCE

 

(MIN)

 

 

 

 

(MIN)

 

 

 

1" (25mm) CLEARANCE

 

 

 

(MIN)

 

 

 

FLOOR

 

FLOOR

 

BASEBOARD HEATER

 

BASEBOARD HEATER

Figure 1. Positioning Drapery Near Heater

NOTE: ALLOW 1/8" (3mm) MINIMUM

CLEARANCE AT ENDS OF HEATER FOR

EXPANSION AND CONTRACTION

NAIL POINTS

FLOOR

Figure 2. Installation of Heater

1. Position the heater at the desired location on the wall as shown in Figure 2. For maximum heating comfort, position the heater under a window.

2. Mark the location on the wall or floor for the power supply entry into the heater. Remove the heater from the wall and drill appropriate hole in the wall or floor.

3. Remove the left or right junction box end cap by removing the screw in the end of the heater and sliding the cap outward from the heater (Figure 3).

4. Remove the front cover of the heater by removing the screws in the lower cor- ners. Pull the bottom of the cover outward and lift the top of the cover off the junction box. Repeat for the opposite end. Snap the top of the cover off the cen- ter bracket and off the intermediate supports. See Figure 4.

5. Remove the appropriate electrical knockout from the back of the heater or accessory if necessary. Supply wiring may also enter the raceway through the floor or wall without using a knockout.

2

Image 2
Contents Model D Example Clearances Installation of Single UnitExample CM3Installation of Multiple Units Minimum CircuitDo not Operating and Maintenance InstructionsLimited Warranty Thermostat Locate Thermostat

D specifications

Marley Engineered Products D is a leading provider of advanced HVAC solutions, offering a range of products designed to improve indoor air quality and enhance energy efficiency. With a focus on innovative technologies and sustainable practices, Marley has established itself as a trusted name in the heating and cooling industry.

One of the standout features of Marley Engineered Products D is its commitment to energy efficiency. The company utilizes state-of-the-art technologies to ensure that its systems operate at optimal levels while minimizing energy consumption. This includes the use of variable speed motors and smart controls that adjust system operation based on real-time conditions. By implementing these technologies, Marley systems not only reduce energy costs for users but also contribute to the overall reduction of greenhouse gas emissions.

Another key characteristic of Marley Engineered Products D is its emphasis on reliability and durability. The products are engineered to withstand the demands of various environments, making them suitable for a wide range of applications, from residential to commercial settings. High-quality materials and rigorous testing processes ensure that the systems can perform effectively under challenging conditions, providing peace of mind to end-users.

Marley also places a strong focus on user-centric design, providing intuitive interfaces that make it easy for users to operate and manage their HVAC systems. This includes smart thermostat compatibility and mobile app integration, allowing users to control their systems remotely and receive real-time alerts for maintenance needs. Such features enhance user experience and promote proactive maintenance, further extending the lifespan of the equipment.

In addition to performance and efficiency, Marley Engineered Products D prioritizes indoor air quality. The company offers advanced filtration options that effectively capture allergens, dust, and other contaminants, ensuring that the air circulated within a space is clean and healthy. This is especially vital in today's climate, where air quality has become a significant concern for homeowners and businesses alike.

Overall, Marley Engineered Products D represents a blend of innovation, efficiency, and reliability. With its commitment to sustainable practices, user-friendly designs, and superior performance, Marley continues to lead the way in the HVAC industry, making it a preferred choice for those looking to enhance their indoor climate while reducing their environmental impact. As the demand for energy-efficient and effective heating and cooling solutions grows, Marley stands ready to meet the challenge with cutting-edge products that address the needs of modern consumers.