Napco Security Technologies GEM-P816, GEM-P1632 Programming the GEM-P3200 & GEM-P9600

Page 10

Programming the GEM-P3200 & GEM-P9600

01 INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

Total Number of Zones and Keypads in Area 1. Total Number of Zones and Keypads in Area 2.

(Appears for New Panel Only)

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

 

 

 

2

 

 

 

 

2

 

 

 

 

2

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press 3to

Press 3to

Press 3to

 

Press 3to

 

select # of

 

select # of

 

select # of

 

 

select # of

zones in Area 1

K/Ps in Area 1

zones in Area 2

 

K/Ps in Area 2

1Press the Abutton and then press 3to select the total number of zones to be programmed for Area 1. Valid entries are from 08 to 24 in multiples of 4.

2Press 2and press 3to select the total number of keypads to be programmed for Area 1.

If no zones are to programmed for Area 2, pressJto save followed by NEXT (E) to proceed.

3If Area 2 is to be programmed, press 2and then press 3to select the total number of zones to be programmed for Area 2.

4Press 2and press 3to select the total number of keypads to be programmed for Area 3.

Note: the first zone of Area 1 (and Area 2, if selected) will automatically be programmed as an Exit/Entry zone with an entry delay of 30 seconds and an exit delay of 60 seconds. The second zone will be programmed as an Exit/Entry Follower Zone. In a single-area system, Zone 8 will be programmed as a 2-Wire Fire Zone (set Jumper JP7 to configure zone 8 for 2 Wire Fire). In a two-area system, zones 7 and 8 will be programmed as 2-Wire Fire Zones and will be common to both areas (set Jumper JP7 to configure zone 7 and 8 for 2 Wire Fire).

02

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

Report all Zones to Central Station?(Appears for New Panel Only)

Press YES (E) button for all zones to report to central station; press NO (F) button for no zones to report (LOCAL SYSTEM).

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

(Yes or No)

03

INTERIOR

BYPASS FIRE/TBL SYS TBL CHIME

 

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

 

 

 

 

(Direct Entry)

Central Station Receiver 1 Telephone Number

Press the Abutton and using the number buttons, directly enter telephone number of up to 16 digits including prefix, if necessary, for receiver 1.

Central Station Receiver 1 Telephone Number

NOTE: Central Station Receiver 2 and 3 Telephone Numbers can be entered in Direct Address Programming. See CS Reporting Options.

Press Jto save . Press NEXT (E) button to proceed.

04 INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

Central Station Receiver 1 Account Number

Press the Abutton and then directly enter an account number of up to four digits.

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Central Station Account #

NOTE: Central Station Receiver 2 and 3 Account Numbers can be entered in Direct Address Programming. See CS Reporting Options.

Press Jto save. Press NEXT (E) button to proceed.

For Central Station Telephone and Account Numbers: Use number buttons 1 through 9 for digits 1–9; press

G0 for a zero and G1 through G5 for letters B–F, respectively. NOTE: Pre-Dial Delay = “D”; Dial-Tone Detection = “E”. Pressing the0button will produce a blank space (•).

10

Image 10
Contents Installation Instructions Page Introduction Easy Program Mode Overview Programming the GEM-P816 & GEM-P1632 Total Number of Zones in Area 1 Appears for New Panel OnlyCentral Station Receiver 1 Telephone Number Number of Keypads in AreaCentral Station Receiver 1 Account Number Central Station Receiver 1 Format Enter User CodesRF Transmitter Programming Key Fob Transmitters Dealer CodeProgramming the GEM-P3200 & GEM-P9600 Universal High Speed RF Transmitter Programming Aux-1 Option see key fob Aux Aux 2 options Direct Address Program Mode 0000Page Napco Recommends That the Entire System

GEM-P9600, GEM-P816, GEM-P1632 specifications

Napco Security Technologies is known for its innovative and robust security solutions, and its GEM series control panels, particularly the GEM-P9600, GEM-P1632, and GEM-P816, exemplify this commitment to excellence in security technology. These panels are designed to meet the diverse needs of residential and commercial properties, offering a combination of reliability, functionality, and user-friendly features.

Starting with the GEM-P9600, this control panel serves as a central hub for monitoring and controlling various security devices. One of its standout features is its ability to support up to 96 zones, making it suitable for larger installations. Its versatile communication capabilities include options for TCP/IP, cellular, and telephone dialer systems, ensuring that users can stay connected regardless of their circumstances. The panel also integrates seamlessly with Napco's range of peripheral devices, including motion detectors, door/window contacts, and glass break sensors, enhancing the overall security ecosystem.

The GEM-P1632 is tailored for medium-sized applications, supporting up to 32 zones. Its user-friendly interface includes an LCD keypad that provides live feedback and allows for easy programming. Just like the GEM-P9600, it supports multiple communication methods, which facilitate real-time alerts and remote management through mobile devices or web applications. The GEM-P1632 also features an advanced event logging system, offering comprehensive records of system activity, which is invaluable for both security professionals and end-users.

In contrast, the GEM-P816 is designed for smaller setups, accommodating up to 16 zones. Despite its compact nature, it boasts many of the same powerful features as its larger counterparts, including compatibility with various communication technologies and integration with smart home systems. Users appreciate its simplified programming, which allows for quick installation and setup. Additionally, with the GEM-P816, end-users have the option to add wireless capabilities, providing flexibility in choosing security devices based on their unique needs.

All three panels utilize advanced technologies, including robust encryption protocols for secure communication and intuitive user interfaces that simplify operation. The GEM series is built with scalability in mind, allowing users to expand their systems effortlessly as their security needs evolve. With a strong emphasis on performance and reliability, Napco's GEM-P9600, GEM-P1632, and GEM-P816 control panels are ideal solutions for anyone looking to enhance the security of their homes or businesses.