Napco Security Technologies GEM-P816, GEM-P9600, GEM-P1632 quick start Introduction

Page 3

INTRODUCTION

The GEM-RP3DGTL is a dual 7-segment digital keypad that is compatible with the NAPCO GEM-Series GEM-P816, P1632, P3200 & P9600 control-panels. Refer to User Guide OI249 for operation instructions. While the GEM-RP3DGTL may be used to fully program the control, the GEM-RP1CAe2 keypad provides the optimum in ease of keypad programming.

SPECIFICATIONS

Operating Voltage: 12 V DC (supplied by panel)

Current Drain:50 mA Standby

Dimensions: 4 3/8” x 5 7/8” x 11/16”

Note: Subtract keypad current from combined auxiliary current of the control panel.

MOUNTING THE KEYPAD

A keypad should be located near each exit/entry door. To open the case, insert a screwdriver into either slot at the bottom and push up with a slight twisting motion to release the retainer tab. Repeat for the other slot. Pull out at the bottom and lift off the two hooks at the top.

The GEM-RP3DGTL features a handy pull-up reference label. (This label must be used in UL installations.) Before mounting the keypad onto the wall, push the Sliding Label Plate (with label and felt backing affixed and handle facing forward) down the guides at the rear of the keypad until it snaps into place. Once installed, the Sliding Label Plate cannot be removed without first removing the keypad from the wall. Note: The keypad fire and panic keys should not be considered a substitute for a listed manual initiating device, such as a pull box.

If installing onto a double-gang box, insert mounting screws through the two vertical elongated holes on the left side of the case and into the box. If the box is visible when viewed from the front, adjust the keypad vertically and tighten the screws. Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad case directly into the wall to ensure a secure installation. Note: Do not over tighten the screws! Uneven walls may cause the keypad case to distort.

WIRING

COLOR

TERMINAL

 

Connect the keypad wires to the control panel

RED

9

 

terminals shown in the table at the right.

BLACK

10

 

 

 

 

GREEN

11

 

Caution: Do not run keypad wiring with loop wiring.

 

 

 

 

YELLOW

12

 

KEYPAD CONFIGURATION

 

 

 

 

WHITE

N/O PANIC

* Cut and insulate 2 white wires if not used.

Up to 7 GEM-RP3DGTL keypads may be connected to

WHITE

N/O PANIC

the control panel (Keypads 1–7). Each must be config-

 

 

ured for a keypad address. In addition,

the keypad may be configured to disable touchpad backlight and entry sounder. Keypads are configured by the proper selection of jumpers. Refer to the label on the keypad circuit board for jumper locations and a summary of settings.

KEYPAD ADDRESS

If more than one keypad is installed:

Each must be assigned a unique address (that is, no two keypads may be numbered alike).

Keypads must be addressed consecutively (that is, missing numbers are not permitted).

Only Keypad No. 1 may be used for programming. (However, for ease of programming, it is recommended that a GEM-RP1CA/ RP1CAe/RP1CAe2 be selected as Keypad #1.)

Assign the keypad address number by selecting Jumpers J1–3 in accordance with the table below.

*Note: (1) Keypads are factory supplied with no jumpers installed and a as such are automatically configured as Key- pad No. 1. (2) Only one keypad in the system may be configured as Keypad No. 1, otherwise none will function.

TOUCHPAD BACK LIGHT

Cut Jumper A to disable touch pad back lighting.

DISABLE SOUNDER

Cut Jumper C to disable the sounder. (Do not disable in UL applications.)

ENABLE KEYPAD TAMPER

Cut Jumper D to enable Keypad Tamper.

ENABLE TAMPER LED

Cut Jumper E to covert the Keypad CHIME LED to a SYSTEM TAMPER LED. (Only on control panels which support system tamper)

KEYPAD

 

JUMPER SETTINGS

NUMBER

1

2

3

PARK

1

OFF or

 

 

ON

 

 

 

2

ON

 

STORE SPARE

3

ON

ON

 

JUMPERS

4

ON

IN THIS

5

ON

ON

POSITION

6

ON

ON

 

7

ON

ON

ON

 

For Sales and Repairs, call toll free: (800) 645-9445

For direct line to Technical Service, call toll free: (800) 645-9440

Internet: http://www.napcosecurity.com

3

Image 3
Contents Installation Instructions Page Introduction Easy Program Mode Overview Total Number of Zones in Area 1 Appears for New Panel Only Programming the GEM-P816 & GEM-P1632Number of Keypads in Area Central Station Receiver 1 Telephone NumberCentral Station Receiver 1 Account Number Enter User Codes Central Station Receiver 1 FormatRF Transmitter Programming Dealer Code Key Fob TransmittersProgramming the GEM-P3200 & GEM-P9600 Universal High Speed RF Transmitter Programming Aux-1 Option see key fob Aux Aux 2 options 0000 Direct Address Program ModePage Napco Recommends That the Entire System

GEM-P9600, GEM-P816, GEM-P1632 specifications

Napco Security Technologies is known for its innovative and robust security solutions, and its GEM series control panels, particularly the GEM-P9600, GEM-P1632, and GEM-P816, exemplify this commitment to excellence in security technology. These panels are designed to meet the diverse needs of residential and commercial properties, offering a combination of reliability, functionality, and user-friendly features.

Starting with the GEM-P9600, this control panel serves as a central hub for monitoring and controlling various security devices. One of its standout features is its ability to support up to 96 zones, making it suitable for larger installations. Its versatile communication capabilities include options for TCP/IP, cellular, and telephone dialer systems, ensuring that users can stay connected regardless of their circumstances. The panel also integrates seamlessly with Napco's range of peripheral devices, including motion detectors, door/window contacts, and glass break sensors, enhancing the overall security ecosystem.

The GEM-P1632 is tailored for medium-sized applications, supporting up to 32 zones. Its user-friendly interface includes an LCD keypad that provides live feedback and allows for easy programming. Just like the GEM-P9600, it supports multiple communication methods, which facilitate real-time alerts and remote management through mobile devices or web applications. The GEM-P1632 also features an advanced event logging system, offering comprehensive records of system activity, which is invaluable for both security professionals and end-users.

In contrast, the GEM-P816 is designed for smaller setups, accommodating up to 16 zones. Despite its compact nature, it boasts many of the same powerful features as its larger counterparts, including compatibility with various communication technologies and integration with smart home systems. Users appreciate its simplified programming, which allows for quick installation and setup. Additionally, with the GEM-P816, end-users have the option to add wireless capabilities, providing flexibility in choosing security devices based on their unique needs.

All three panels utilize advanced technologies, including robust encryption protocols for secure communication and intuitive user interfaces that simplify operation. The GEM series is built with scalability in mind, allowing users to expand their systems effortlessly as their security needs evolve. With a strong emphasis on performance and reliability, Napco's GEM-P9600, GEM-P1632, and GEM-P816 control panels are ideal solutions for anyone looking to enhance the security of their homes or businesses.