Napco Security Technologies GEM-P1632, GEM-P816, GEM-P9600 quick start RF Transmitter Programming

Page 8

Programming the GEM-P816 & GEM-P1632

15 INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

 

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

 

 

 

 

(Direct Entry)

Zone #

6-digit RF ID #

RF Transmitter Programming

(For wireless systems only. Also see Quick Method, which follows)

Press the A button and for each transmitter (key fob transmitters also), then directly enter:

1The zone number (01–32) to which the transmitter will be mapped, including leading zeros.

2The 6-digit RF ID # printed on the transmitter and box.

3The 1-digit checksum number (C) printed on the transmitter and box.

4The Point number (1–4) (P); enter “9” for unsupervised (all points).

Press Jto save. Then go to step 1 to enter next transmitter. When all

transmitters are entered, press NEXT (E) button to proceed.

NOTE: When programming the RF ID number: “A” =G0; “B” =G1;

Checksum # Point # “C” =G2; “D” =G3; “E” =G4; “F” =G5.

Quick Method. If a receiver is already installed in the panel, Napco transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure.NOTE: The transmitter point will be enrolled only if the signal strength is 3 or greater.

1.Enter the zone number to which the transmitter point will be mapped.

2.Press the Bbutton to enter the Enroll Mode. The red and green LEDs on the keypad will flash.

3.Open the loop of the point that is to be programmed (GEM-TRANS2 only).

4.Install the transmitter battery. The keypad will beep once to indicate that the point has been successfully enrolled. Multi-point transmitters can be mapped to successive zones simultaneously (Example 1) or to selected zones point by point (Example 2).

Example 1. A GEM-TRANS2 transmitter has the RF ID number 410078:1. Map both points to Zones 11–12, respectively.

1.Enter the Enroll mode as described in step 2 above.

2.Enter Zone “11”.

3.Open the loops of points 1 and 2.

4.Install the transmitter battery. The keypad will beep 3 times to indicate that three points have been programmed.

Transmitter 410078:1, point 1 will be mapped to Zone 11.

Transmitter 410078:1, point 2 will be mapped to Zone 12.

The keypad will now display Zone 12, the last zone enrolled.

Example 2. A GEM-TRANS2 transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9.

1.Enter the Enroll mode as described above.

2.Enter Zone “06”.

3.Open point-1 loop.

4.Install the battery. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1, point 1 will be mapped to Zone 6.)

5.Enter Zone “09”.

6.Close point-1 loop and open point-2 loop.

7.Remove the transmitter battery, then re-install it. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1, point 2 is mapped to Zone 9.)

KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm system, each reporting to a central station, or pager while having a description on the keypad that describes the person holding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the key fob button being depressed. See the next page on Key fob Zone Assignment.

8

Image 8
Contents Installation Instructions Page Introduction Easy Program Mode Overview Programming the GEM-P816 & GEM-P1632 Total Number of Zones in Area 1 Appears for New Panel OnlyCentral Station Receiver 1 Account Number Number of Keypads in AreaCentral Station Receiver 1 Telephone Number Central Station Receiver 1 Format Enter User CodesRF Transmitter Programming Key Fob Transmitters Dealer CodeProgramming the GEM-P3200 & GEM-P9600 Universal High Speed RF Transmitter Programming Aux-1 Option see key fob Aux Aux 2 options Direct Address Program Mode 0000Page Napco Recommends That the Entire System

GEM-P9600, GEM-P816, GEM-P1632 specifications

Napco Security Technologies is known for its innovative and robust security solutions, and its GEM series control panels, particularly the GEM-P9600, GEM-P1632, and GEM-P816, exemplify this commitment to excellence in security technology. These panels are designed to meet the diverse needs of residential and commercial properties, offering a combination of reliability, functionality, and user-friendly features.

Starting with the GEM-P9600, this control panel serves as a central hub for monitoring and controlling various security devices. One of its standout features is its ability to support up to 96 zones, making it suitable for larger installations. Its versatile communication capabilities include options for TCP/IP, cellular, and telephone dialer systems, ensuring that users can stay connected regardless of their circumstances. The panel also integrates seamlessly with Napco's range of peripheral devices, including motion detectors, door/window contacts, and glass break sensors, enhancing the overall security ecosystem.

The GEM-P1632 is tailored for medium-sized applications, supporting up to 32 zones. Its user-friendly interface includes an LCD keypad that provides live feedback and allows for easy programming. Just like the GEM-P9600, it supports multiple communication methods, which facilitate real-time alerts and remote management through mobile devices or web applications. The GEM-P1632 also features an advanced event logging system, offering comprehensive records of system activity, which is invaluable for both security professionals and end-users.

In contrast, the GEM-P816 is designed for smaller setups, accommodating up to 16 zones. Despite its compact nature, it boasts many of the same powerful features as its larger counterparts, including compatibility with various communication technologies and integration with smart home systems. Users appreciate its simplified programming, which allows for quick installation and setup. Additionally, with the GEM-P816, end-users have the option to add wireless capabilities, providing flexibility in choosing security devices based on their unique needs.

All three panels utilize advanced technologies, including robust encryption protocols for secure communication and intuitive user interfaces that simplify operation. The GEM series is built with scalability in mind, allowing users to expand their systems effortlessly as their security needs evolve. With a strong emphasis on performance and reliability, Napco's GEM-P9600, GEM-P1632, and GEM-P816 control panels are ideal solutions for anyone looking to enhance the security of their homes or businesses.