KEYPAD CONTROLS & INDICATORS

1Window. Lights indicate system status messages; digit display indicates related zone, function or error message numbers.

2STATUS Light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured the light will be off and the zone will display in the window. If a zone has been bypassed, the STATUS light will blink while armed.

3ARMED Light. Lights (red) to indicate that the system is armed. If an alarm has occurred, the ARMED LED will be flashing.

4MENU Button. Selects available system functions as displayed in the window. The selected function is executed by pressing the Ubutton.

5BYPASS Button. (1) Deactivates selected zones from the system. (2)

Unbypasses a bypassed zone. (GEM- P3200/9600 panels only).

6RESET Button. (1) Resets various system troubles, displays, etc. (See text.) (2) Resets residential smoke detectors.

7Numerical Keys (1-9, 0). Used to enter codes, zone numbers, etc.

8ENTER Button. Entry key. Causes the entered code or selected function to be executed.

9STAY Button. (1) Bypasses all Interior Zones simultaneously ("STAY Mode") to allow free movement within the premises. Hold down P

when the system is armed in "STAY Mode" to cancel entry delay on Exit/ Entry Zones, causing an instant alarm upon violation. (2) Scrolls the window display forward (NEXT). (3) Answers “YES” to questions in the window display.

10

11

12

13

AWAY Button. (1) Arms all zones in the system. (2) Scrolls window display backward (PRIOR). (3) Answers “NO” to questions in the window display.

AREA Button (G). Selects other

areas and is used with emergency buttons.

Emergency Buttons. Used with the G butt o n t o s ig n a l an

emergency, as follows:

Press the 7and the G buttons for Fire Emergency.

Press the 8and the G buttons for Auxiliary Emergency.

Press the 9and the G buttons for Police Emergency.

AC Light. Indicates AC Power is present.

5

Image 5
Contents GEM-DXK3 Keypad Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators Keypad Controls & Indicators Arming the System Arming AW AY Setting the Alarm When LeavingPriority Arming Selectively Bypassing ZonesArea Arming Optional Managers ModeInstant Protection Arming in Stay ModeArming Stay Protecting Yourself AT Home Emergency Buttons Only available if programmed Alarm Indication / Silencing an Alarm Turning OFF the AL ARM Disarming When ReturningTo silence an audible alarm Disarming the SystemFire-Zone Trouble Fire ProtectionImportant! Read Carefully Preparing a Fire Escape PlanFamily Rehearsal Floorplan Limitations of Fire Alarm Warning System Function Menu System troubles. For GEM-P9600/3200 panels only Reset System Trouble? Function Menu Function Menu Central Station Monitoring Communicator FeaturesSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart Programming User Codes Entering the User Program ModeProgramming / Reprogramming a User Code Erasing a User CodeProgramming Example Exiting the User Program ModeArming/Disarming Turning the system on or off, as follows GlossaryRF Low Battery Wireless Priority Zone a zone that Trouble System Trouble Action Indication Condition System Trouble Error Codes06-NN 12-NN E19-00 What do I do if For more info TroubleshootingWithout charge to the original purchaser or user Napco Limited Warranty

GEM-DXK3 specifications

Napco Security Technologies has long been a prominent player in the security industry, and its GEM-DXK3 series exemplifies the company's commitment to innovation and user-friendly design. This security control panel is tailored primarily for residential and small business applications, providing a versatile solution to meet the growing demands for safety and surveillance.

One of the standout features of the GEM-DXK3 is its remarkable flexibility in compatibility. The panel supports a wide range of security sensors, including door/window contacts, motion detectors, and glass break detectors. This adaptability allows users to customize their security systems according to specific needs, ensuring comprehensive coverage throughout their property.

The GEM-DXK3 is equipped with advanced technology that enhances its performance and reliability. It uses the latest digital and analog signal processing, which ensures efficient operation and faster response times. This capability minimizes false alarms and provides more accurate alerts when a security breach occurs.

Moreover, the GEM-DXK3 is designed with user convenience in mind. It features an intuitive keypad interface that simplifies programming and operation. Users can easily navigate through settings and adjust their security preferences without hassle. Additionally, an optional LCD touchscreen is available, offering a modern approach to control and monitoring, further enhancing user experience.

Communication is key in security systems, and the GEM-DXK3 excels in this area. It supports multiple communication methods, including landline, internet, and cellular, ensuring that alerts can be sent to users and monitoring stations without interruption. This multi-channel approach provides an extra layer of reliability and security, as users are less likely to miss critical notifications.

The GEM-DXK3 also integrates seamlessly with Napco's mobile app, which allows users to monitor and control their security systems remotely. This functionality is especially beneficial for users who want to keep an eye on their properties while away, providing peace of mind and added convenience.

With its combination of flexibility, advanced technology, user-friendly design, and robust communication capabilities, Napco Security Technologies' GEM-DXK3 stands out as a comprehensive security solution. Whether for home or small business use, this control panel addresses the needs of modern security applications effectively.