Napco Security Technologies GEM-DXK3 Arming AW AY Setting the Alarm When Leaving, Priority Arming

Page 6

ARMING AW AY: SETTING THE ALARM WHEN LEAVING

12 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

P INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

Arming the System

1.Check the keypad. The green STATUS light must be on in order to arm.

If the green light is off, the number(s) of any unsecured zone(s) will display in the window. Refer to the pull-up zone list for the location of each problem zone and secure by closing windows, doors, etc.. When all zones are secure, the green STATUS light will come on.

2.Arm the system. Enter your User Code followed by Q. The green

STATUS light will go off, the red ARMED light will come on. Note: If you enter an invalid code, the keypad will beep 4 times, indicating an error. Re-enter your code.

3.Leave the premises. Leave through the exit door before the exit time expires.

Priority Arming

If you attempt to arm the system with a faulted Zone, a 3-second tone will sound at the keypad and “P” will display in the window, indicating that the zones must be secured before the panel can be armed.

INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

Selectively Bypassing Zones

If you cannot locate or repair a faulted zone, it can be removed from the system, or bypassed. Bypass the zone(s) from the system by pressing B, followed by

the zone number (or vice versa). The yellow BYPASS light will turn on to indicate that the zone has been bypassed.

Note: Bypassed zones are unprotected. If a faulted zone cannot be secured, have the system checked as soon as possible.

6

Image 6
Contents GEM-DXK3 Keypad Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators Keypad Controls & Indicators Priority Arming Arming AW AY Setting the Alarm When LeavingArming the System Selectively Bypassing ZonesManagers Mode Area Arming OptionalArming in Stay Mode Arming Stay Protecting Yourself AT HomeInstant Protection Emergency Buttons Only available if programmed To silence an audible alarm Turning OFF the AL ARM Disarming When ReturningAlarm Indication / Silencing an Alarm Disarming the SystemFire Protection Fire-Zone TroublePreparing a Fire Escape Plan Family RehearsalImportant! Read Carefully Floorplan Limitations of Fire Alarm Warning System Function Menu System troubles. For GEM-P9600/3200 panels only Reset System Trouble? Function Menu Function Menu Communicator Features Central Station MonitoringAdvanced Features Exit-Delay RestartSecurity Bypass/Unbypass Programming / Reprogramming a User Code Entering the User Program ModeProgramming User Codes Erasing a User CodeExiting the User Program Mode Programming ExampleGlossary Arming/Disarming Turning the system on or off, as followsRF Low Battery Wireless Priority Zone a zone that System Trouble Error Codes Trouble System Trouble Action Indication Condition06-NN 12-NN E19-00 Troubleshooting What do I do if For more infoNapco Limited Warranty Without charge to the original purchaser or user

GEM-DXK3 specifications

Napco Security Technologies has long been a prominent player in the security industry, and its GEM-DXK3 series exemplifies the company's commitment to innovation and user-friendly design. This security control panel is tailored primarily for residential and small business applications, providing a versatile solution to meet the growing demands for safety and surveillance.

One of the standout features of the GEM-DXK3 is its remarkable flexibility in compatibility. The panel supports a wide range of security sensors, including door/window contacts, motion detectors, and glass break detectors. This adaptability allows users to customize their security systems according to specific needs, ensuring comprehensive coverage throughout their property.

The GEM-DXK3 is equipped with advanced technology that enhances its performance and reliability. It uses the latest digital and analog signal processing, which ensures efficient operation and faster response times. This capability minimizes false alarms and provides more accurate alerts when a security breach occurs.

Moreover, the GEM-DXK3 is designed with user convenience in mind. It features an intuitive keypad interface that simplifies programming and operation. Users can easily navigate through settings and adjust their security preferences without hassle. Additionally, an optional LCD touchscreen is available, offering a modern approach to control and monitoring, further enhancing user experience.

Communication is key in security systems, and the GEM-DXK3 excels in this area. It supports multiple communication methods, including landline, internet, and cellular, ensuring that alerts can be sent to users and monitoring stations without interruption. This multi-channel approach provides an extra layer of reliability and security, as users are less likely to miss critical notifications.

The GEM-DXK3 also integrates seamlessly with Napco's mobile app, which allows users to monitor and control their security systems remotely. This functionality is especially beneficial for users who want to keep an eye on their properties while away, providing peace of mind and added convenience.

With its combination of flexibility, advanced technology, user-friendly design, and robust communication capabilities, Napco Security Technologies' GEM-DXK3 stands out as a comprehensive security solution. Whether for home or small business use, this control panel addresses the needs of modern security applications effectively.