Monessen Hearth DSSNVMB, DSSPVMB Troubleshooting, Observed Problem Possible Cause Remedy

Page 24

TROUBLESHOOTING

WARNING

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

When ignitor button is pressed, there is no spark at ODS/pilot.

1.Ignitor electrode positioned wrong.

2.Ignitor electrode is broken.

3.Ignitor electrode not connected to ignitor cable.

4.Ignitor cable pinched or wet. Keep ignitor cable dry.

5.Broken ignitor cable.

6.Bad piezo ignitor.

7.No battery power (auto spark).

1Replace ignitor.

2. Replace ignitor.

3. Reconnect ignitor cable.

4.Free ignitor cable if pinched by any metal or tubing.

5.Replace ignitor cable.

6.Replace piezo ignitor.

7.Replace battery.

Appliance produces unwanted

1.

Appliance burning vapors from paint, hair

odors.

 

spray, glues, etc.

 

2.

Gas leak.

 

3.

Initial burn off.

1.Ventilate room. Stop using odor causing products while heater is running.

2.Locate and correct all leaks.

3.Ventilate room and turn unit on high until odor is gone. Odor should be gone after 2 to 3 hours of continuous use.

Appliance shuts off during use. 1. Not enough fresh air is available for ODS/ pilot to operate.

2.Low line pressure.

3.ODS/pilot is partially clogged.

4.Defective Thermopile.

5.Restrictions in incoming air flow.

1.Open window and/or door for ventila- tion.

2.Contact local gas company.

3.Clean ODS/pilot.

4.Check pilot flame. Check wire connec- tions. Check thermopile output — should be 500 milli-volts across TH/TP and TP Terminals with ON/OFF switch off.

5.Check for obstructions on bottom of unit. Check for improper log placement.

Gas odor even when control knob

1.

Gas leak.

1.

Locate and correct all leaks.

is in OFF position.

2.

Control valve defective.

2.

Replace control valve.

 

 

 

 

 

When ignitor button is pressed,

1.

Gas supply turned off or appliance shutoff

1.

Turn on gas supply or open manual

there is spark at ODS pilot, but

 

valve closed.

 

shutoff valve.

no ignition.

2.

Air in gas lines when installed.

2.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed.

 

3.

ODS/pilot is clogged.

3.

Replace ODS/pilot assembly or get it

 

 

 

 

serviced.

 

4.

Gas regulator setting is not correct (LPG).

4.

Replace gas regulator at tank.

24

46D0550

Image 24
Contents Models Dssnvmb Dsspvmb What to do if YOU Smell GASRead and Save These Instructions Contents Important Safety Information InstallerOwner From Product Features Cast Iron StoveWhat YOU will Need for Installation Getting StartedMake Sure YOU have Received ALL Parts Product Specifications General Installation Information Stove DimensionsCodes Adequate Combustion and Ventilation AIRCounter Steel Stove L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 FtClearances / Height Requirments Ceiling Mantel Side Wall FloorConnecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure and Connecting Remote Receiver Connecting Remote ReceiverMillivolt Control Figure Remote ReceiverElectrical Wiring MILLI-VOLT Connecting Optional Wall Switch or ThermostatChecking System Operation Complete Millivolt System CheckInstalling Thermostat Sensor Option Sold Separately Knob Screws Thermo Bulb Wiring Harnesses Stat SensorFace Plate ScrewsStat Sensor On/Off Switch Control Knob Optional Blower Operation of Thermostat SensorPlastic Clip LOG Placement Log #4 Log #2 Back Pins FrontFlame AP Pearance Checking Burner FlameOperating Instructions Checking Pilot FlameOperating Instructions Hi/Lo Knob Blower DoorSwitch Hi/Lo Control Ignitor/Pilot Control Optional T-StatOperating Instructions and Cleaning and Servicing Cleaning and ServicingReplacement Parts List LogsReplacement Parts Burner AssemblyDSS Models Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame 46D0550 46D0550 Lifetime Warranty Five Year WarrantyBasic Warranty

DSSPVMB, DSSNVMB specifications

Monessen Hearth has established itself as a reliable name in the realm of home heating solutions, providing innovative products that are both functional and aesthetically pleasing. Among its impressive line-up are the DSSNVMB and DSSPVMB models, which are designed to offer homeowners effective and stylish heating options.

The DSSNVMB (Natural Vent) and DSSPVMB (Propane Vent) are part of Monessen's commitment to creating products that look good while delivering exceptional performance. Both models feature a sleek, modern design that allows them to seamlessly fit into various types of home decor. Their visual appeal, combined with practical utility, makes them a popular choice among homeowners.

One of the most significant features of these models is their efficient venting system. The DSSNVMB utilizes natural venting technology, which allows it to expel exhaust gases through an existing chimney, eliminating the need for external venting systems. This feature not only saves on installation costs but also enhances the overall energy efficiency of the unit. In contrast, the DSSPVMB is designed for propane use, boasting a direct venting system that draws air from outside while expelling gases, creating a closed system that maximizes efficiency and safety.

Both models come equipped with advanced burner technology, ensuring an even and controlled flame that optimizes heat output. This means that homeowners can enjoy consistent warmth without fluctuations in performance. The adjustable flame settings allow users to customize their heating experience to meet individual preferences, creating a tailored comfort level.

Moreover, the DSSNVMB and DSSPVMB are designed with user-friendliness in mind. The easy-to-use control systems allow for straightforward operation, making it simple for homeowners to manage their heating needs. Additionally, these models often come with options for remote control, providing convenience in adjusting the temperature from anywhere in the room.

Safety is a top priority in the design of Monessen's products. The DSSNVMB and DSSPVMB are equipped with built-in safety features, including automatic shut-off systems that activate if any irregularities are detected during operation. This reassurance of safety provides peace of mind for users.

In summary, the Monessen Hearth DSSNVMB and DSSPVMB models exemplify modern home heating solutions that combine efficiency, user-friendliness, and design. With their advanced technologies, stylish appearance, and robust safety features, these units are perfect for any homeowner looking to enhance their living space while enjoying the comfort of efficient heating.