CLEARANCES AND HEIGHT REQUIREMENTS

WARNING

The dimensions shown in Figures 7 and 8 and defined in the fireplace manufacturer's instructions are minimum clearances to maintain when installing this heater. Left and right clearances are determined when facing the front of the heater.

Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.

Sidewall and ceiling clearances: The clear- ance from the inside of the appliance to any com- bustible adjacent wall should no be less than 9". See Figure 7.

Ceiling clearance: The ceiling must be at least 42" from the top of the firebox opening. See Figure 7.

Back wall clearance: The appliance may be placed against a combustible back wall.

Floor clearance: The fireplace may not be installed onto any combustible flooring material, such as carpeting, vinyl or tile without the hearth or a minimum 22 GA (0.030") metal or a minimum 1/2" wooden base covering the entire width and depth of the base. Combustible material must be installed at least one inch away from the front face of the unit.

Mantel clearances: The canopy supplied with the unit must be installed. If a combustible mantel is installed. It must meet the clearance requirements shown in Figure 8.

 

42" Minimum

9"

9"

Minimum

Minimum

Figure 7 - Sidewall and Ceiling Clearances

Combustible material can contact top of fireplace.

12"

10"

8"

6"

23"

21/2" 16" 19"21" 12"

N o n - c o m b u s t i b l e material only if needed to cover optional radiant top panel above canopy.

Figure 8B - Mantel Heights

Figure 8A - Minimum Mantel Clearances

For Wide Brass Canopy. See pg. 35

14

71D0532

Image 14
Contents What to do if YOU Smell GAS Read and Save These InstructionsContents Owner Important Safety InformationInstaller From Product Features OperationNatural GAS PROPANE/LPGSpecifications Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started General Installation Information Firebox Dimensions with Screen and Log SetsCodes Adequate Combustion and Ventilation AIRBTU/Hr = 15 1/ 2 x 12 x 1000 = 29760 BTU/Hr Installing Canopy Removing ScreenDo not Install this Model in a Bedroom or Bathroom Location of FireplaceClearances and Height Requirements 21/2 16 1921Fireplace Framing Framing surfacefireplace must be installed giving Connecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure MILLI-VOLT Control FigureOperate Electrical WiringConnecting Optional Wall Switch Complete MILLI-VOLT System Check Connecting Remote ReceiverChecking System Operation LOG Placement Installing Charred Timber Logs on BurnerInstalling Left Base Log #3 Installing Left Top Log #5 Installing Right Top Log #6 Placing Rock WoolMILLI-VOLT Control Flame AppearanceChecking the Pilot Flame Checking the Burner Flame Correct Appearance of Rear Flames of Charred TimberOperating Instructions For Your Safety Read Before Lighting MILLI-VOLT Control Lighting Instructions Operating InstructionsOperating Instructions and Cleaning and Servicing Cleaning and ServicingForced AIR KIT Blower and Other Optional EquipmentOptional Equipment Optional TrimIllustrated Parts Breakdown Charred Timber LogsIllustrated Parts Breakdown Accessories Sold Separately Replacement Parts ListBurner Assembly Illustrated Parts Breakdown BRC36 BRC42 Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame Trim Installation Trim Installation For USE of Optional AK-4 Outside AIR KIT Combustion AIRModel AK-4 Combustion AIR Assembly Insulation Ring to Left Side of FireplaceInstalling Model 403 Duct Connector 71D0532 Five Year Warranty Basic Warranty