Monessen Hearth 7000 Series Optional DC Remote Systems, Millivolt Control Valve Checklist

Page 18

GAS LINE AND ELECTRICAL INSTALLATION

Figure 13: Wiring Diagram for Standing Pilot - Millivolt System

Optional DC Remote Systems

These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote.

NOTE

Remote receiver must be mounted outside the appliance, due to high temperatures inside the chamber. This

will prevent failures and longer battery life.

1.Plug in the remote connector wire to the remote receiver.

2.Mount remote control receiver at junction box (for your wall switch)

3.Connect the ¼” female connector to the valve TPTH and TH terminal.

Millivolt Control Valve Checklist:

The millivolt (thermopile) control is a self-powered combustion gas control. Refer to Figure 13: Wiring Diagram for Standing Pilot - Millivolt System. The millivolt system and individual components may be checked with a millivolt meter having 1-1000 mV range. Conduct each check listed below by connecting the meter test leads to the terminals indicated. Refer to OPERATING INSTRUCTIONS for safety and lighting instructions.

Thermopile Output Check

Pilot must be lit and the valve control knob turned to the “PILOT” or “ON” position. “RS-ON-OFF” switch must be in the “OFF” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve. If the meter reading is not 500-millivolt minimum, then readjust pilot for maximum millivolt output. If millivolt reading is still below minimum specified, check wire connection and then replace the thermopile.

Complete Millivolt System Check

17

Image 18
Contents Series Table of Contents Important Safety Information Important Safety InformationAlways Burn Propane Models with Doors Closed Product SPECIFICATIONS/LISTING & Code Approval Listing & Code ApprovalModel LAB Type Certification Standard Items Required For Installations Tools Building Supplies PRE-INSTALLATION InformationContents Before You StartFireplace Dimensions PRE-INSTALLATION Information Combustible Clearances Mantel Clearances Mantel Clearance Floor ClearancesCombustible Vent Installation Vertical Venting Straight up No ElbowPiping Installations Vertical Venting with Two 2 45 Degree ElbowTo Locate and Install Ceiling Firestop Ceiling Firestop Location Vent Termination For Vertical TerminationTo Locate and install Vertical Termination Outside Air Kit InstallationGAS Line and Electrical Installation Do not use open flame to check for gas leaksStanding Pilot Ignition Wiring-Millivolt Control Remote Wall SwitchThermopile Output Check Millivolt Control Valve ChecklistOptional DC Remote Systems Complete Millivolt System CheckElectronic Pilot Ignition Wiring Wiring Diagram for Electronic Ignition SystemGAS Line and Electrical Installation Wall Finishing Rock Wool PlacementLava Rock Placement DefinitionsLog Placement for fiber VDY24/18D3R Log PlacementDoor Rail Installation Damper Operation Hi Temperature Cut Off Disc Lighting the Fireplace Operating InstructionsBefore Lighting the Fireplace You may notice the followingFor Your Safety Read Before Lighting Lighting Instructions Millivolt ControlTo Turn OFF GAS to Appliance Lighting Instructions Electronic IGN Maintenance Standing-Pilot Flame OnlyBurner Flame Soot cleaning fluid may be used on refractory logs Vent SystemGlass Door Parts List / Illustrations Parts List / IllustrationVDY24/18D3R Description 4536 5142 Engine Components Conversion Kit Not Shown for Millivolt-Control OnlyConversion Kit Not Shown for Electronic Ignition Page Electronic Ignition General Troubleshooting Limited Lifetime Warranty Policy 41D2002 Rev 5 April