GAS LINE AND ELECTRICAL INSTALLATION
Pilot must be lit and the valve control knob turned to the “ON” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve.
•Turn
9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.
9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.
•Turn
9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.
9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.
Electronic Pilot Ignition Wiring:
WARNING
Do not connect
Figure 14: Wiring Diagram for Electronic Ignition System
Remote Wall Switch
Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not extend beyond the 15 feet of wire.
18