Napoleon Fireplaces NZ25 manual Trouble Shooting

Page 16

16TROUBLE SHOOTING

Build your fire on the floor of the firebox and be- hind the log retainer only.

Do not block or restrict the hot air outlets or air inlets. This will cause the fireplace to overheat.

Keep fires away from the door .

DOs:

1.Build a hot fire.

2.Use only dry wood

3.Several pieces of medium sized wood are better than a few big pieces.

4.Clean the chimney regularly.

5.Refuel frequently using medium sized wood.

6."Fine Tune" the air settings for optimum perform- ance.

Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be be expected. When first lighting a fire, if the smoke is not quickly drawn into the chimney, there may be a downdraft or cold air in the chim- ney. Roll up some newspaper, light it and place it near the fireplace flue until the chimney begins to draw. During a firing, open the draft control before opening the fireplace door. Open the door slowly to avoid drawing smoke into the room.

A properly installed Napoleon fireplace should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the fireplace or chimney? Is the room too airtight and the air intake not connected to the outside? Check with a win- dow partly open. Is the smoke flow impeded by too long a horizontal pipe or too many bends? Is it a weak draft per- haps caused by a leaky chimney, a cold outside chimney, too short a chimney, or a chimney too close to trees or a higher roof?

DON'Ts:

1.Take ash out immediately. Let it accumulate to a depth of at least one inch. A good ash layer provides for a longer lasting and better burning fire.

2.Burn wet wood.

3.Close the door too soon or damper down too quickly.

4.Burn one large log rather than two or three smaller, more reasonably sized logs.

5.Burn at continually 'low setting', if the glass door is constantly blackened. This means the firebox tem- perature is too low.

MAINTENANCE

Check your chimney for creosote and soot build-up monthly until a safe frequency for cleaning is established. If accu- mulation is excessive, clean the chimney. You may want to call a professional chimney sweep to clean it. Both the chimney and the fireplace have to be cleaned at least once a year or as often as necessary. See the Section on Creo- sote Formation and Removal.

WS-415-71 /09.07.00

Image 16
Contents Solid Fuel Burning Zero Clearance Table of Contents Napoleon Wood Fireplace Presidents Lifetime Limited Warranty Conditions and LimitationsGeneral Information IntroductionGeneral Instructions Care of Glass and Plated Parts Four OptionsInstall Ation / Framing Location and ClearancesSee Framing Section FramingOutside Combustion AIR Hearth ExtensionMantle Clearances Chimney Installation Installing Flashing and Storm Collar Offset Chimney InstallationAdding Chimney Sections Connection to a Masonry Chimney If the ChimneyFirebrick Removal Attaching the HandleBlower Install Ation OptionalControlling Combustion AIR NZ25 FeaturesFuel Loading and Burn Cycle ASH Removal Procedures Maintenance ReplacementsReplacement Parts Accessories / OptionsTrouble Shooting