Napoleon Fireplaces NZ25 manual Offset Chimney Installation, Adding Chimney Sections

Page 9

1. Move the fireplace into position. Try to center the ex-

haust flue of the fireplace, midpoint between two joists to

OFFSET CHIMNEY INSTALLATION

9

prevent having to cut them. Use a plumb bob to line up the

centre.

2. Cut and frame an opening in the ceiling to provide a

minimum clearance of 2" between the outside of the chim-

ney and any combustible material. DO NOT FILL THIS

SPACE WITH ANY TYPE OF MATERIAL! Nail headers

between the joists for extra support. Firestop spacers must

be placed on the bottom of each framed opening in any

floor or ceiling that the chimney passes through.

3. Hold a plumb bob from the underside of the roof to

determine where the opening in the roof should be. Cut

and frame the roof opening maintaining proper 2" clear-

ances.

An insulated elbow must be used when it becomes nec- essary to offset the chimney in order to clear a joist or to pass through an upstairs closet.

Attach an elbow to the chimney section, angled toward the offset. Secure with 3 - #8X1/2" sheet metal screws. To achieve the minimum offset, attach and secure a return elbow to the first. To achieve longer offsets, you may install any available length of chimney pipe between the elbows.

Supports must be used on the first vertical chimnney sec- tion after a return elbow.

FIGURE12

FIGURE11

ADDING CHIMNEY SECTIONS

Add chimney sections, twist locking (clockwise) securely, to the required height. Use a rafter radiation shield when- ever the chimney system is enclosed within an attic area.

FIGURE14

INSTALLING FLASHING AND STORM COLLAR

Remove the nails from the shingles above and to the sides of the chimney. Place the flashing over the chimney pipe and slide underneath the sides and upper edge of the shingles. Ensure that the chimney pipe is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof on the top and sides. DO NOT NAIL through the lower portion of the flashing. Make weather-tight by seal- ing with caulking. Where possible, cover the sides and top edges of the flashing with roofing material. Apply water- proof caulking, provided with the flashing, around the chim- ney, 1" above the top of the flashing and push the storm collar down into the caulking. Insert a rain cap onto the top of the last chimney section.

FIGURE13

FIGURE15

WS-415-71 /09.07.00

Image 9
Contents Solid Fuel Burning Zero Clearance Table of Contents Conditions and Limitations Napoleon Wood Fireplace Presidents Lifetime Limited WarrantyIntroduction General InformationGeneral Instructions Four Options Care of Glass and Plated PartsLocation and Clearances Install Ation / FramingSee Framing Section FramingHearth Extension Outside Combustion AIRMantle Clearances Chimney Installation Offset Chimney Installation Installing Flashing and Storm CollarAdding Chimney Sections If the Chimney Connection to a Masonry ChimneyFirebrick Removal Attaching the HandleOptional Blower Install AtionNZ25 Features Controlling Combustion AIRFuel Loading and Burn Cycle ASH Removal Procedures Replacements MaintenanceAccessories / Options Replacement PartsTrouble Shooting

NZ25 specifications

The Napoleon Fireplaces NZ25 is a standout option for those looking to enhance their living space with an elegant and efficient heating solution. This stylish fireplace embodies the perfect blend of cutting-edge technology, aesthetic appeal, and practical functionality.

One of the key features of the NZ25 is its impressive heating capacity. Designed for medium to large living areas, the fireplace is capable of producing a remarkable 20,000 BTUs (British Thermal Units) per hour. This potent output makes it an ideal choice for homeowners seeking to maintain a comfortable atmosphere during colder months.

The NZ25 is built with innovative heating technologies that prioritize efficiency. The fireplace utilizes a high-efficiency design, ensuring that a greater portion of the fuel is converted into heat rather than lost through the chimney. As a result, it not only heats your space more effectively but also reduces fuel consumption, making it an eco-friendly option for conscientious consumers.

Moreover, the NZ25 features Napoleon’s Advanced Airflow System, which ensures optimized heat distribution throughout the room. This technology enhances the fireplace's heating capabilities, allowing for consistent warmth and comfort, regardless of where you're seated in the room. Paired with an array of customizable settings, users can effortlessly control the flame and heat output to suit their specific preferences.

The aesthetic appeal of the NZ25 is another highlight. It offers an attractive contemporary design that complements various interior styles, making it a beautiful focal point in any living area. The fireplace can be customized with an assortment of decorative media, which allows homeowners to personalize the look and feel of their space.

Safety is also a top priority with the NZ25. It features a robust safety screen and has been designed to minimize the risk of accidents. With Napoleon’s commitment to quality, the NZ25 is built to last, ensuring that it remains a reliable heating source for years to come.

In summary, the Napoleon Fireplaces NZ25 combines an impressive heating output with modern efficiency technologies and appealing design. Whether for warmth or aesthetics, this fireplace represents an excellent investment for any home.