Napoleon Fireplaces GDS28P manual Vertical AIR Terminal Installation

Page 23

23

4.2.4 VERTICAL AIR TERMINAL INSTALLATION

!WARNING

MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR.

A. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.

B.

Stretch the inner flex pipe to the required length. Slip the

 

 

 

inner flex pipe a minimum of 2” over the inner pipe of the air

 

 

 

terminal connector and secure with 3 #8 screws. Seal using

 

 

 

a heavy bead of high temperature sealant W573-0007 (not

 

 

 

supplied).

 

 

C.

Repeat using the outer flex pipe, using a heavy bead of

 

ROOF SUPPORT

 

 

 

high temperature sealant W573-0002 (not supplied).

 

 

D.

Thread the air terminal connector / vent pipe assembly down through

 

INNER PIPE

 

 

 

the roof. The air terminal must be positioned vertically and plumb.

 

 

 

Attach the air terminal connector to the roof support, ensuring that the

AIR

 

top of the air terminal is 16” above the highest point that it penetrates

 

TERMINAL

 

the roof.

CONNECTOR

E.Remove nails from the shingles, above and to the sides of the air terminal connector. Place the flashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above

the top of the flashing. Slide the flashing underneath the sides and upper edge of the shingles. Ensure that the air terminal connector is properly centred within the flashing, giving a 3/4” margin all around. Fasten to the roof. Do not nail through the lower portion of the flashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the flashing with roofing material.

HIGH TEMPERATURE SEALANT

INNER FLEX PIPE

OUTER FLEX PIPE

F.

Aligning the seams of the terminal and air terminal connector,

2”

AIR INLET

 

BASE

 

place the terminal over the air terminal connector making sure

 

 

 

CAULKING

 

the vent pipe goes into the hole in the terminal. Secure with the

 

 

three screws provided.

 

STORM COLLAR

G.

Apply a heavy bead of weatherproof caulking 2” above the

 

WEATHER

 

SEALANT

 

flashing. Install the storm collar around the air terminal and slide

 

 

 

 

down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved.

FLASHING

H.If more vent pipe needs to be used to reach the appliance see “HORIZONTAL AIR TERMINAL INSTALLATION” section.

24.1

W415-0153 / B / 06.10.10

Image 23
Contents What to do if YOU Smell GAS Installation Operating InstructionsTable of Contents Installation Overview Introduction General Instructions DimensionsWe suggest that our gas GDS28 General InformationOutput CS280/GS28RENDEMENT Rating Plate InformationVenting Refer to the section applicable to your installationPart Supplier Website Venting Lengths and ComponentsPlus Rise Typical Vent InstallationMinimum Feet Maximum MinimumMIN. to Grade Special Vent Installations 3.3.1 Periscope TerminationMinimum MIN. to Grade Covered Balcony Applications †† Vent Terminal ClearancesFeet Inches Venting Application Flow Chart TOP ExitDefinitions Elbow Vent Length ValuesHT VT Simple venting configuration only one 90 elbow TOP Exit Horizontal TerminationHT VT TOP Exit Vertical Termination Simple venting configurationsV T Pipe Vertical Through Existing ChimneyMinimum Clearances to Combustibles InstallationWall and Ceiling Protection Horizontal InstallationHorizontal AIR Terminal Installation Model GDS28 Vertical InstallationVertical AIR Terminal Installation Self Drilling Mobile Home Installation Model GDS28High Temperature Sealant Appliance Vent ConnectionWire Size MAX. Length GAS InstallationOptional Wall Switch / Thermostat / Remote Vent Specifics Chimney Installation Plates and Gasket Installing B VentAdding Vent Sections Combustion AIRDoor Closing and Opening FinishingLOG Placement Charcoal Embers Logo PlacementGlowing Embers Model GS28 only Venting Action Check OperationTo Turn OFF GAS OPERATING/LIGHTING InstructionsLighting Instructions Venturi Adjustment AdjustmentPilot Burner Adjustment Sensor Flame Must Envelop Flame CharacteristicsRestricting Vertical Vents Model GDS28 BurnerCare of Glass MaintenanceBlower Replacement Common Components ReplacementsGS28 Components Common Accessories 51 52 46 45 Symptom Problem Trouble ShootingDo not Over Torque Symptom Problem Test SolutionGDS28 Conditions and Limitations WarrantyService History 44.1 44.1

GDS28P specifications

Napoleon Fireplaces has long been a respected name in the world of home heating, and the GDS28P model is a shining example of the brand's dedication to quality and efficiency. This direct vent gas stove is not only a stylish addition to any living space, but it also boasts a range of features and technologies that enhance both performance and user experience.

One of the standout features of the GDS28P is its compact yet powerful design. With a heat output of up to 20,000 BTUs, this stove is capable of warming areas up to 1,000 square feet. Its impressive heating capacity makes it ideal for use in a variety of home settings, whether in a cozy living room or as a supplementary heating source in a larger open floor plan.

The GDS28P incorporates Napoleon's advanced high-efficiency technology, which maximizes heat output while minimizing emissions. The unit features a dual burner system that allows for both a lively flame and a more subdued ambiance. The adjustable flame height and heat output provide homeowners with complete control over their heating experience, ensuring comfort throughout the colder months.

Another notable characteristic is the GDS28P's sleek design, which includes a large viewing area, allowing for an unobstructed view of the alluring flames. The stove is available in a range of finishes, making it easy to integrate into various decor styles. The large glass front allows users to enjoy the mesmerizing effect of the fire, while also ensuring that heat is efficiently radiated into the room.

Additionally, the GDS28P is equipped with a state-of-the-art electronic ignition system, providing reliable startup even in the coldest conditions. The built-in fan kit enhances air circulation, ensuring even heat distribution throughout any space. The unit can be operated via a remote control, allowing users to easily adjust settings while lounging comfortably.

For those concerned about the environment, the GDS28P exceeds the stringent guidelines set by the EPA, providing a cleaner burn compared to traditional wood stoves. This not only reduces your carbon footprint, but it also means less maintenance and cleaning.

In summary, the Napoleon Fireplaces GDS28P is a cutting-edge heating solution that combines efficiency, style, and user-friendly features. Its powerful heating capabilities, advanced technologies, and aesthetic appeal make it a valuable addition to any home, providing warmth and enhancing living spaces while safeguarding the environment.