Napoleon Fireplaces GDS28P manual Trouble Shooting, Symptom Problem

Page 42

42

10.0TROUBLE SHOOTING

!WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,

WITH THE GLASS DOOR OPEN OR REMOVED.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

SYMPTOM

PROBLEM

TEST SOLUTION

Main burner goes out; pilot stays on.

Pilot flame is not large enough or not engulfing the thermopile.

-Turn up the pilot flame.

-Replace pilot assembly.

 

Thermopile shorting.

-

Clean thermopile connection to the valve. Reconnect.

 

 

-

Replace thermopile / valve.

 

Remote wall switch wire is too

-

Shorten wire to correct length or wire gauge.

 

long; too much resistance in

 

 

 

the system.

 

 

 

Faulty thermostat or switch.

-

Replace.

Main burner goes out; pilot goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”

Vent is blocked

-

Check for vent blockage.

Vent is re-circulating

-

Check joint seals and installation

Flexible vent has become

-

Re-attach to appliance.

disconnected from appliance.

-

Cap was not replaced.

Pilot goes out when the gas knob is released.

The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

System is not correctly purged

-

Purge the gas line.

 

 

 

Out of propane gas.

-

Fill the tank.

Pilot flame is not large

-

Turn up the pilot flame.

enough.

 

 

Pilot flame is not engulfing the

-

Gently twist the pilot head to improve the flame pattern

thermocouple

 

around the thermocouple.

Thermocouple shorting / faulty.

-

Loosen and tighten thermocouple.

 

-

Clean thermocouple and valve connection.

 

-

Replace thermocouple.

 

-

Replace valve.

Faulty valve.

-

Replace.

Pilot burning; no gas to main burner; gas knob is on ‘HI’; wall switch / thermostat is on.

Thermostat or switch is

-

Connect a jumper wire across the wall switch terminals;

defective

 

if main burner lights, replace switch / thermostat.

Wall switch wiring is defective.

-

Disconnect the switch wires & connect a jumper wire

 

 

across terminals 1 & 3; if the main burner lights, check

 

 

the wires for defects and/or replace wires.

Main burner orifice is plugged.

-

Remove stoppage in orifice.

 

 

Faulty valve.

-

Replace.

Pilot goes out while

 

Gas piping is undersized.

-

Turn on all gas appliances and see if pilot flame flutters,

standing; Main burner is in

 

 

 

diminishes or extinguishes, especially when main burner

‘OFF’ position.

 

 

 

ignites. Monitor appliance supply working pressure.

 

 

 

-

Check if supply piping size is to code. Correct all

 

 

 

 

undersized piping.

Main burner flame is a

 

Blockage in vent.

-

Remove blockage. In really cold conditions, ice buildup

blue, lazy, transparent

 

 

 

may occur on the terminal and should be removed as

flame.

 

 

 

required.

 

 

Incorrect installation.

-

Ensure correct location of storm collars.

 

 

 

 

 

42.3

 

 

 

 

 

W415-0153 / B / 06.10.10

Image 42
Contents Installation Operating Instructions What to do if YOU Smell GASTable of Contents Installation Overview Introduction Dimensions General InstructionsWe suggest that our gas General Information GDS28Rating Plate Information Output CS280/GS28RENDEMENTRefer to the section applicable to your installation VentingVenting Lengths and Components Part Supplier WebsiteMinimum Typical Vent InstallationMinimum Feet Maximum Plus RiseSpecial Vent Installations 3.3.1 Periscope Termination Minimum MIN. to GradeMIN. to Grade Vent Terminal Clearances Covered Balcony Applications ††Elbow Vent Length Values Venting Application Flow Chart TOP ExitDefinitions Feet InchesTOP Exit Horizontal Termination HT VT Simple venting configuration only one 90 elbowHT VT Simple venting configurations TOP Exit Vertical TerminationV T Vertical Through Existing Chimney PipeInstallation Minimum Clearances to CombustiblesHorizontal Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Model GDS28Vertical AIR Terminal Installation Appliance Vent Connection Mobile Home Installation Model GDS28High Temperature Sealant Self DrillingGAS Installation Optional Wall Switch / Thermostat / RemoteWire Size MAX. Length Vent Specifics Chimney Installation Installing B Vent Plates and GasketCombustion AIR Adding Vent SectionsFinishing Door Closing and OpeningLOG Placement Logo Placement Glowing EmbersCharcoal Embers Operation Model GS28 only Venting Action CheckOPERATING/LIGHTING Instructions Lighting InstructionsTo Turn OFF GAS Adjustment Pilot Burner AdjustmentVenturi Adjustment Burner Flame CharacteristicsRestricting Vertical Vents Model GDS28 Sensor Flame Must EnvelopMaintenance Care of GlassBlower Replacement Replacements Common ComponentsGS28 Components Common Accessories 51 52 46 45 Trouble Shooting Symptom ProblemSymptom Problem Test Solution Do not Over TorqueGDS28 Warranty Conditions and LimitationsService History 44.1 44.1

GDS28P specifications

Napoleon Fireplaces has long been a respected name in the world of home heating, and the GDS28P model is a shining example of the brand's dedication to quality and efficiency. This direct vent gas stove is not only a stylish addition to any living space, but it also boasts a range of features and technologies that enhance both performance and user experience.

One of the standout features of the GDS28P is its compact yet powerful design. With a heat output of up to 20,000 BTUs, this stove is capable of warming areas up to 1,000 square feet. Its impressive heating capacity makes it ideal for use in a variety of home settings, whether in a cozy living room or as a supplementary heating source in a larger open floor plan.

The GDS28P incorporates Napoleon's advanced high-efficiency technology, which maximizes heat output while minimizing emissions. The unit features a dual burner system that allows for both a lively flame and a more subdued ambiance. The adjustable flame height and heat output provide homeowners with complete control over their heating experience, ensuring comfort throughout the colder months.

Another notable characteristic is the GDS28P's sleek design, which includes a large viewing area, allowing for an unobstructed view of the alluring flames. The stove is available in a range of finishes, making it easy to integrate into various decor styles. The large glass front allows users to enjoy the mesmerizing effect of the fire, while also ensuring that heat is efficiently radiated into the room.

Additionally, the GDS28P is equipped with a state-of-the-art electronic ignition system, providing reliable startup even in the coldest conditions. The built-in fan kit enhances air circulation, ensuring even heat distribution throughout any space. The unit can be operated via a remote control, allowing users to easily adjust settings while lounging comfortably.

For those concerned about the environment, the GDS28P exceeds the stringent guidelines set by the EPA, providing a cleaner burn compared to traditional wood stoves. This not only reduces your carbon footprint, but it also means less maintenance and cleaning.

In summary, the Napoleon Fireplaces GDS28P is a cutting-edge heating solution that combines efficiency, style, and user-friendly features. Its powerful heating capabilities, advanced technologies, and aesthetic appeal make it a valuable addition to any home, providing warmth and enhancing living spaces while safeguarding the environment.