Vermont Casting RDVOD 3399, RDVOD 3354 Wall Centerline from Floor, Wall and Ceiling Clearances

Page 6

Radiance Direct Vent/Natural Vent Gas Heater

Parallel Installation: Minimum Clearance

and Flue Centerline, Direct Vent and Natu-

ral Vent

42" (1070mm)

Min. Alcove Width

4" (102mm)

48"

(1220mm) Max. Alcove Depth

 

 

 

6"

 

 

 

6"

 

 

 

 

 

 

 

ST130

 

(150mm)

 

 

 

(150mm)

Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines.

Corner Installation: Minimum Clear- ance and Flue Centerline, Direct Vent & Natural Vent

18"

(457mm)

6"

(150mm)

18"

(457mm)

6"

(150mm)

ST129

Fig. 4 Corner installation, minimum corner clearances and flue centerline.

Wall Centerline from Floor

Direct Vent Only

A

ST131b

A

Effective Minimum

Centerline 57” (1448mm)(Vermont Castings/Majestic Pipe)

55” (1399mm) (Simpson DuraVent Pipe)

Fig. 5 Minimum wall centerline.

Wall and Ceiling Clearances

Direct Vent Only

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

B

C

A

A: Rear Wall

4” (102mm)

B: Min. Clearance

44” (1118mm)*

C: Min. Alcove Height

72” (1830mm)*

D: Max. Alcove Depth

48” (1220mm)

Sidewall Clearance

6” (150mm)

*needed for installing DuraVent Minimum Vent Kit #2792 or

CFM Corporation Minimum Vent Kit #7TFSMSK.

ST101b

 

Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Radiance Heaters must be installed on rigid floor- ing. When the heater is installed directly on any com- bustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.

66

20004188

Image 6
Contents Radiance Table Of Contents Installation & Operating Instructions Verify proper operation after servicingRadiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsInstallation Requirements Locating The StoveClearance Requirements Wall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestictor Plate is used on Direct Vent installations only Vertical Termination Direct Vent onlyVent Termination Clearances Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Tools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Fan kit componentsFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach the Inner Vent Assembly to the stoveSide Wall Termination Assembly Install the Outer Adapter Pipe. Orient the vertiDiscard the inner starter pipe shipped with the log Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineBurner Information Install ON/OFF SwitchInstall the Mesh and Grille Thermostat Connection optionalOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Models 3350, 3351, 3360 thru 3369 R Models OnlyPilot Type 1 SIT Pilot Pilot type 2 Honeywell PilotModels 3352, 3354, 3390 thru 3399 RF Models Only All Models Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to Natural Gas Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Optional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

RDVOD 3360, RDVOD 3369, RDVOD 3354, RDVOD 3350, RDVOD 3399 specifications

Vermont Castings is renowned for its exceptional wood stoves and fireplaces, and the RDVOD series stands as a testament to their commitment to craftsmanship, efficiency, and innovative technology. The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 models embody a blend of traditional aesthetics and modern functionality, making them standout choices for homeowners seeking warmth and style.

One of the main features of the RDVOD series is its high-efficiency rating. These models utilize Vermont Castings' advanced combustion technology, which optimizes fuel usage, resulting in more heat output from less wood. This not only reduces overall wood consumption but also minimizes emissions, making these stoves environmentally friendly options for heating.

The RDVOD stoves are designed with robust cast iron construction, ensuring durability and longevity. The cast iron provides excellent heat retention and leads to a more consistent warmth in the home. Additionally, the stylish design of these models allows them to seamlessly integrate into various home decors, from rustic to contemporary.

Key technologies incorporated into these stoves include the patented "Biltmore" technology, which enhances the efficiency of the burning process. This technology ensures that the fire burns hotter and cleaner, providing more heat while reducing the pollutants released into the atmosphere. The adjustable air controls allow users to easily manage the flame and heat output, ensuring personalized comfort.

The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 also feature large glass doors that showcase the fire, adding visual appeal to any living space. The seamless integration of the glass doors with the cast iron design contributes to the overall aesthetic while allowing for easy monitoring of the fire.

Safety is another priority in the design of the RDVOD stoves. They come equipped with features like a removable ash pan, which simplifies cleanup and maintenance, and the air-wash system, which keeps the glass clean, providing an unobstructed view of the flames.

In summary, the Vermont Castings RDVOD series – including models 3399, 3350, 3360, 3390, and 3369 – exemplifies high efficiency, exquisite craftsmanship, and thoughtful technology. With their combination of aesthetic appeal and functional performance, they offer an optimal heating solution for today’s homeowners seeking comfort and elegance in their living spaces.