Vermont Casting RDVOD 3399 manual Lighting and Operating Instructions, To Turn Off Gas To Heater

Page 24

Radiance Direct Vent/Natural Vent Gas Heater

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”.

 

 

 

ILO

T

�����

���

 

 

 

P

 

t

 

1

 

 

 

 

 

F

 

 

 

lo

 

 

��

��

 

F

 

 

 

P

 

 

 

 

 

i

 

2

O

 

 

 

O

 

 

 

 

 

 

 

F

 

 

 

F

 

 

 

 

 

 

5

 

3

FFO

 

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

2424

20004188

Image 24
Contents Radiance Table Of Contents Installation & Operating Instructions Verify proper operation after servicingRadiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsInstallation Requirements Locating The StoveClearance Requirements Wall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Specifications Gas Inlet and Manifold PressuresHigh Elevations Horizontal Termination Direct Vent onlyRestictor Plate is used on Direct Vent installations only Vertical Termination Direct Vent onlyVent Termination Clearances Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Assembly Procedures Parts Bag ContentsTools Required Unpack and Assemble LegsInstall the Optional Fan Fan kit componentsVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeFor Canadian installations The venting system must Attach the Inner Vent Assembly to the stoveSide Wall Termination Assembly Install the Outer Adapter Pipe. Orient the vertiDiscard the inner starter pipe shipped with the log Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineInstall ON/OFF Switch Install the Mesh and GrilleBurner Information Thermostat Connection optionalFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path On Path Auto Path Conversion Precautions Conversion ProcedureFuel Conversion Instructions Models 3350, 3351, 3360 thru 3369 R Models OnlyPilot Type 1 SIT Pilot Pilot type 2 Honeywell PilotModels 3352, 3354, 3390 thru 3399 RF Models Only Air Shutter Adjustment Injector Orifice Size MatrixAll Models Conversion to Natural Gas Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Optional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

RDVOD 3360, RDVOD 3369, RDVOD 3354, RDVOD 3350, RDVOD 3399 specifications

Vermont Castings is renowned for its exceptional wood stoves and fireplaces, and the RDVOD series stands as a testament to their commitment to craftsmanship, efficiency, and innovative technology. The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 models embody a blend of traditional aesthetics and modern functionality, making them standout choices for homeowners seeking warmth and style.

One of the main features of the RDVOD series is its high-efficiency rating. These models utilize Vermont Castings' advanced combustion technology, which optimizes fuel usage, resulting in more heat output from less wood. This not only reduces overall wood consumption but also minimizes emissions, making these stoves environmentally friendly options for heating.

The RDVOD stoves are designed with robust cast iron construction, ensuring durability and longevity. The cast iron provides excellent heat retention and leads to a more consistent warmth in the home. Additionally, the stylish design of these models allows them to seamlessly integrate into various home decors, from rustic to contemporary.

Key technologies incorporated into these stoves include the patented "Biltmore" technology, which enhances the efficiency of the burning process. This technology ensures that the fire burns hotter and cleaner, providing more heat while reducing the pollutants released into the atmosphere. The adjustable air controls allow users to easily manage the flame and heat output, ensuring personalized comfort.

The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 also feature large glass doors that showcase the fire, adding visual appeal to any living space. The seamless integration of the glass doors with the cast iron design contributes to the overall aesthetic while allowing for easy monitoring of the fire.

Safety is another priority in the design of the RDVOD stoves. They come equipped with features like a removable ash pan, which simplifies cleanup and maintenance, and the air-wash system, which keeps the glass clean, providing an unobstructed view of the flames.

In summary, the Vermont Castings RDVOD series – including models 3399, 3350, 3360, 3390, and 3369 – exemplifies high efficiency, exquisite craftsmanship, and thoughtful technology. With their combination of aesthetic appeal and functional performance, they offer an optimal heating solution for today’s homeowners seeking comfort and elegance in their living spaces.