Vermont Casting RDVOD 3399, RDVOD 3354 manual Fuel Conversion Instructions, Conversion Precautions

Page 30

Radiance Direct Vent/Natural Vent Gas Heater

Fuel Conversion Instructions

WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion

or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.

 

OFF

I

N

H O

O

 

TPILOJAD

 

Main

 

Gas Line

Gas Supply Inlet

 

ST226

Fig. 52 Attach the gas line to the left side of the valve.

Conversion Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.

Conversion Procedure

1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 32, Fig. 62)

2.Undo the right and left latches at the top of the glass frame. (Page 32, Fig. 63)

3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.

4.Remove the logset from the firebox.

5.Remove the rear log bracket by loosening the screw and lifting the bracket up and away. (Fig. 53)

6.Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 53)

Remove Screws

Rear Log Bracket

 

 

 

Pilot

 

Left & Right Log

ST350

 

Bracket Assembly

Fig. 53 Remove rear log bracket and left and right log bracket assembly.

7.Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.

8.Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 61)

9.Install conversion orifices. (Refer to Table 1)

10.Air shutter adjustment. The unit is shipped from the factory with the air shutter open 1”. For LP units only, the air shutter could be closed further. Refer to Table 2 for minimum air shutter opening. The air shutter is located on the bottom of the burner to the left. Unfasten the two nuts holding the shutter in place. Adjust the air shutter as needed according to Table 2. (Fig. 54)

Refer to Table 2

Burner

 

ST667

Fig. 54 Adjust air shutter according to Table 2.

Models 3350, 3351, 3360 thru 3369 (R Models) Only

11.Remove cap from Hi-Lo knob. This can be accom- plished by lifting the plastic cap off the screw. (Fig. 55)

12.Remove the screw from center of Hi-Lo knob with small screwdriver turning counterclockwise. (Fig. 55)

13.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.

3030

20004188

Image 30
Contents Radiance Table Of Contents Installation & Operating Instructions Verify proper operation after servicingRadiance Direct Vent/Natural Vent Stove Dimensions Radiance dimensionsInstallation Requirements Locating The StoveClearance Requirements Wall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestictor Plate is used on Direct Vent installations only Vertical Termination Direct Vent onlyVent Termination Clearances Location of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Plate supplied with the stove is not usedVenting Requirements and Options Direct Vent only Tools Required Assembly ProceduresParts Bag Contents Unpack and Assemble LegsInstall the Optional Fan Fan kit componentsFor Canadian installations The venting system must Venting System Assembly Direct Vent General InformationInstall the Vent Adapter Pipe Attach the Inner Vent Assembly to the stoveSide Wall Termination Assembly Install the Outer Adapter Pipe. Orient the vertiDiscard the inner starter pipe shipped with the log Measure the horizontal length Vertical Through the Roof Vent Assembly Vent Termination Below GradeVenting System Assembly Natural Vent General Information Install firestops and attic insulation shieldInstall the Vent Pipe Install Log SetInstall the left and right rear logs and the right log Connect the Gas Supply LineBurner Information Install ON/OFF SwitchInstall the Mesh and Grille Thermostat Connection optionalOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On Path Auto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Models 3350, 3351, 3360 thru 3369 R Models OnlyPilot Type 1 SIT Pilot Pilot type 2 Honeywell PilotModels 3352, 3354, 3390 thru 3399 RF Models Only All Models Air Shutter AdjustmentInjector Orifice Size Matrix Conversion to Natural Gas Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Wiring Diagrams BLKRadiance Direct Vent/Natural Vent Gas Heater Rdvod DescriptionRadiance Direct Vent/Natural Vent Gas Heater Rdvod Optional Accessories Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

RDVOD 3360, RDVOD 3369, RDVOD 3354, RDVOD 3350, RDVOD 3399 specifications

Vermont Castings is renowned for its exceptional wood stoves and fireplaces, and the RDVOD series stands as a testament to their commitment to craftsmanship, efficiency, and innovative technology. The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 models embody a blend of traditional aesthetics and modern functionality, making them standout choices for homeowners seeking warmth and style.

One of the main features of the RDVOD series is its high-efficiency rating. These models utilize Vermont Castings' advanced combustion technology, which optimizes fuel usage, resulting in more heat output from less wood. This not only reduces overall wood consumption but also minimizes emissions, making these stoves environmentally friendly options for heating.

The RDVOD stoves are designed with robust cast iron construction, ensuring durability and longevity. The cast iron provides excellent heat retention and leads to a more consistent warmth in the home. Additionally, the stylish design of these models allows them to seamlessly integrate into various home decors, from rustic to contemporary.

Key technologies incorporated into these stoves include the patented "Biltmore" technology, which enhances the efficiency of the burning process. This technology ensures that the fire burns hotter and cleaner, providing more heat while reducing the pollutants released into the atmosphere. The adjustable air controls allow users to easily manage the flame and heat output, ensuring personalized comfort.

The RDVOD 3399, RDVOD 3350, RDVOD 3360, RDVOD 3390, and RDVOD 3369 also feature large glass doors that showcase the fire, adding visual appeal to any living space. The seamless integration of the glass doors with the cast iron design contributes to the overall aesthetic while allowing for easy monitoring of the fire.

Safety is another priority in the design of the RDVOD stoves. They come equipped with features like a removable ash pan, which simplifies cleanup and maintenance, and the air-wash system, which keeps the glass clean, providing an unobstructed view of the flames.

In summary, the Vermont Castings RDVOD series – including models 3399, 3350, 3360, 3390, and 3369 – exemplifies high efficiency, exquisite craftsmanship, and thoughtful technology. With their combination of aesthetic appeal and functional performance, they offer an optimal heating solution for today’s homeowners seeking comfort and elegance in their living spaces.