Vermont Casting 4040 - 4046 Minimum Clearances to Combustible Materials, Hearth Requirements

Page 5

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus- tible materials and the heater as specified below for the appropriate firebox shell being installed.

Freestanding Stove

 

D

 

 

B

A

C

 

 

ST101

Hearthmount

 

D

 

 

B

A

C

 

 

 

 

 

 

 

 

 

 

 

ST102

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: Mantel/Trim*

 

35” (889 mm) / 2”

(51 mm)

B: Side Wall/Trim*

 

 

 

2”

(51 mm)

C: Rear Wall

 

 

 

0” (0 mm)

D: Max. Mantel Width

 

 

 

13” (330 mm)

Alcove Clearances

B

 

 

 

 

 

B

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

ST103

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: Ceiling

 

 

 

35” (889 mm)

B: Side Wall

 

 

 

2” (51 mm)

C: Rear Wall

 

 

 

 

0” (0 mm)

D: Max. Alcove Depth

 

 

 

13” (330 mm)

UVS27 Vent-Free Gas Heater

 

A

 

 

 

 

 

B

 

 

 

 

C

 

 

 

S

D

 

 

 

T

E

 

 

 

U

 

F

 

 

V

W

G

 

 

 

 

 

 

 

 

 

 

X

Y

H

 

 

 

 

 

 

 

Z

 

 

 

 

 

ST599a

 

Mantel

 

Mantel from

Ref.

Shelf Depth

Ref.

Stove Top

A

13” (330mm)

S

35”

(889 mm)

B

11¹⁄” (286 mm)

T

30”

(762 mm)

C

9³⁄” (241 mm)

U

25”

(635 mm)

D

7¹⁄” (191 mm)

V

20”

(508 mm)

E

5³⁄” (146 mm)

W

15”

(381 mm)

F

4” (102 mm)

X

10”

(254 mm)

G

2¹⁄” (57 mm)

Y

5” (127 mm)

H

1” (25 mm)

Z

2”

(51 mm)

Hearth Requirements

The Freestanding Stove and Hearthmount Shell must be installed on rigid flooring. If the appliance is installed on any combustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit.

WARNING

Do not install this heater in a bathroom or bed- room.

Installation of this heater must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 / NFPA54.

This heater creates warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where im- purities in the air such as tobacco smoke exist, may discolor walls.

Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

20007068

5

Image 5
Contents UVS27R, UVS27M Table Of Contents Carbon Monoxide Poisoning MAY Lead to Death Installation & Operating InstructionsUVS27 freestanding shell dimensions Shell DimensionsMinimum Clearances to Combustible Materials Do not install this heater in a bathroom or bed- roomHearth Requirements Mantel fromGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Odor During OperationFresh Air Requirements for Combustion Ventilation Vent Free FeaturesProvide For Adequate Ventilation Unusually Tight ConstructionExample R N I N GUnpack the Stove Assembly ProceduresInstall Optional Fan Kit Thermostat Connection Optional Install ON/OFF SwitchGlass & Catalyst Installation Remove air shutter, turn upside down and replace Aged Logs Install Log SetConnect the Gas Supply Line Install rear, left and right logs Complete the InstallationInstall the Top Plate and Grille Flame Characteristics Flame & Temperature AdjustmentOperation Your First FireWhat to do if YOU Smell GAS Lighting and Operating InstructionsTo Turn Off Gas To Heater Ignitor Electrode sparks, but Pilot does not light TroubleshootingNo spark at pilot when Ignitor is operated Pilot lights but Main Burner does not Troubleshooting cont’dMain Burner shuts off and Pilot flame goes out while in operationFirebox Cleaning and Inspection MaintenanceCleaning Procedure Glass ReplacementCatalytic Combustor Clean the Combustor ModuleRemove the Combustor Module Replace the Combustor ModuleUVS27R, UVS27M Vent Free Gas Heaters UVS27 DescriptionClassic Remote Controls Optional Accessories AvailableFan Kits Glass / Catalyst Kit UvgodcfkUVS27 Vent-Free Gas Heater UVS27 Vent-Free Gas Heater Limited Lifetime Warranty CFM Specialty Home Products

4085 - 4087, 4030 - 4036, 4090 - 4092, 4040 - 4046 specifications

Vermont Casting gas fireplaces are renowned for their high-quality construction and elegant designs, making them popular choices among homeowners seeking both functionality and aesthetic appeal. The models 4030, 4036, 4040, 4046, 4085, 4087, 4090, and 4092 represent a range of offerings that showcase the brand’s commitment to craftsmanship and innovation.

The Vermont Casting 4030 and 4036 models are characterized by their compact size and traditional styling, making them a great fit for smaller spaces. Both models employ advanced gas-burning technologies, ensuring efficient heat output and reduced emissions. The clean line design enhances any interior, while the expansive glass door allows for a clear view of the flames, adding to the ambiance of the room.

The 4040 and 4046 models expand upon this foundation, catering to larger spaces without sacrificing efficiency. These fireplaces can be fitted with either natural gas or propane, providing flexibility based on the homeowner’s preferences. The 4046, with its increased BTU output, is particularly effective in heating larger areas, making it a reliable choice during colder months.

Moving on to the 4085 and 4087 models, they are designed with larger viewing areas and a modern aesthetic, which appeals to contemporary tastes. These models also incorporate Vermont Castings' Clean Burn technology, which maximizes heat generation while minimizing pollutants released into the air. This technology makes the 4085 and 4087 environmentally friendly choices for conscientious consumers.

Finally, the 4090 and 4092 models take versatility to another level, offering distinctive designs that can complement various decor styles. Both come equipped with customizable options, including different finishes and decorative fronts, allowing homeowners to tailor their fireplace to match their preferences. The inclusion of advanced electronic ignition systems makes these models user-friendly, ensuring a hassle-free experience when lighting and operating the fireplace.

In conclusion, the Vermont Casting fireplace models 4030, 4036, 4040, 4046, 4085, 4087, 4090, and 4092 exemplify a blend of tradition, innovation, and customization. Their features promote efficient heating and aesthetic appeal, making them desirable options for any home environment. Whether for cozy evenings or entertaining guests, these fireplaces promise to enhance the warmth and charm of any space.