Vermont Casting 2477 manual Installation, Chimney Types, Masonry Chimneys

Page 4

Dutchwest Non-Catalytic Convection Heater

Installation

SAFETY NOTICE: IF YOUR DUTCHWEST CON- VECTION HEATER IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLA- TION, OPERATION AND MAINTENANCE DIREC- TIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.

Before you begin the installation, review your plans to confirm that:

Your stove and chimney connector will be far enough from combustible material to meet all clearance require- ments.

The floor protector is large enough and is constructed properly to meet all requirements.

You have obtained all necessary permits from local authorities.

Your local building official is the final authority for ap- proving your installation as safe and for determining that it meets local and state codes.

Clearance and installation information is printed on the metal label attached to the rear of the stove. Local au- thorities generally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved.

Codes vary in different areas, however. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.

Important: Failure to follow these installation instruc- tions may result in a dangerous situation, including a chimney or house fire. Follow all instructions exactly, and do not allow makeshift compromises to endanger property and personal safety.

Chimney Types

Your Dutchwest Convection Heater must be connected to 1) a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys, Fac- tory-Built, Residential Type and Building Heating Appli- ance, UL 103, or 2) a code-approved masonry chimney with a flue liner.

Whatever kind you use, the chimney and chimney con- nector must be in good condition and kept clean.

Masonry Chimneys

If you use an existing masonry chimney, it must be inspected to ensure safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able either to make the inspection or to direct you to some- one who can.

An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chim- ney should also be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.

Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.

The chimney should be thoroughly cleaned before use.

A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Masonry chimneys must be lined, either with code-approved masonry or pre-cast refractory tiles, stainless steel pipe, or a code-approved, “poured-in-place” liner. The chimney’s clean-out door must seal tightly.

Prefabricated Double-Wall

Insulated Chimney

Tile Lined

Masonry

Chimney

ST241

Fig. 2 If in sound condition and approved for use, either a masonry or a prefabricated chimney may be used.

4

30002314

Image 4
Contents Non-Catalytic Convection Heater Model Table of Contents Accessories Specifications ModelChimney Types InstallationMasonry Chimneys Guidelines for Installing the Chimney Connector Two Types of ConnectorSingle-Wall Connector Prefabricated ChimneysAssembling Single-Wall Chimney Connector Double-Wall ConnectorSecuring the Connector to a Prefabricated Chimney Freestanding Installations Securing the Connector to a Masonry ChimneyFireplace Installations Above the Fireplace Fireplace Installations Through the Fireplace Wall Pass-ThroughsFloor Protection CanadaFireplace Installations ProcedureFireplace Installation Clearances ClearancesKeep the Stove a Safe Distance From Surrounding Materials Safe Ways to Reduce ClearancesAlcove Installations Construction RequirementsDesigning a Safe Installation Clearance Chart Reference DiagramsCorner Parallel Installations Stove Clearance Side Rear Chimney Connector ClearanceRight Side OnlyCorner Parallel Installations Chimney Connector Side Rear Dutchwest Convection Heater ModelWall Heat Shield Dimensions DutchWest Non-Catalytic Convection Heater Model #2477Unpack the Parts AssemblyAttach the Legs and Heat Shield Fan Kit Installation Heater Controls and Features Air Control OperationBurn Only High-Quality Fuel Damper Function Successful Wood BurningLoad Doors How to Build and Maintain a Wood Fire Loading Wood Use the Air Control Settings That Work Best for YouBreak-in Fires Lighting the Fire Reloading and Reviving the FireRemove Ashes Frequently Safe Ash HandlingMaintenance Cleaning the GlassAdjust the Door Latch Test and Repair the Door GasketsPrimary Air Control Adjustment Damper AdjustmentAvoid Damaging the Glass Door Panel Cleaning the Chimney System Inspect Regularly, Clean As RequiredTWO Weeks Draft Management Draft Testing Single VentingFuel CreosoteDutchwest Convection Heater Dutchwest Convection Heater Limited Lifetime Warranty Months, whichever is longer

2477 specifications

The Vermont Castings 2477 is a highly regarded wood-burning stove that epitomizes both craftsmanship and modern technology, making it a favored choice among wood stove enthusiasts. This powerful yet stylish stove is designed to provide exceptional heating efficiency while enhancing the aesthetic appeal of any living space.

One of the standout features of the Vermont Castings 2477 is its innovative design that combines traditional aesthetics with contemporary functionality. The stove features a large viewing window, allowing for a mesmerizing view of the flames, which creates a warm and inviting ambiance in any room. Its cast iron construction not only adds to the classic look but also ensures durability and long-lasting performance.

The stove has an impressive heat output, capable of heating spaces of up to 2,500 square feet, making it suitable for both small and medium-sized homes. It comes equipped with an efficient EPA-certified combustion system, which dramatically reduces emissions and optimizes fuel use. This technology allows users to enjoy a longer burn time with less firewood, thus enhancing overall efficiency and making it an environmentally friendly option.

The Vermont Castings 2477 features a secondary combustion system that enhances the burning process. By introducing air into the firebox, it ensures that gases are consumed efficiently, resulting in a cleaner burn. The stove is also equipped with a built-in ash pan that simplifies cleanup, allowing users to easily dispose of the ash without the hassle of removing the entire firebox.

In terms of customization, owners appreciate the variety of finishes available, ranging from classic black to vivid enamel colors, allowing for personalization to match different home decors. Additionally, the stove includes adjustable air controls, which enable users to regulate the burn rate and heat output based on their specific needs.

Lastly, installation of the Vermont Castings 2477 is straightforward, and it can be fitted with various chimney configurations, further enhancing its versatility. With its combination of style, technology, and efficiency, the Vermont Castings 2477 wood stove represents an excellent investment for anyone looking to embrace the warmth and charm of a wood-burning heating solution in their home.