Vermont Casting 1695CE Connecting Flue Pipe - Clearances, Vermont Castings Intrepid Multi-Fuel

Page 10
Connecting Flue Pipe - Clearances

Vermont Castings Intrepid Multi-Fuel

B

Manual background AManual background

Fig. 10 Minimum clearances.

Connecting Flue Pipe - Clearances

Single wall connecting fluepipes can reach extremely high temperatures; therefore, clearances from the con- necting fluepipe (chimney connector) must comply with the requirements of Part J of Building Regulations 2000 (Combustion Appliances and Fuel Storage Systems). This can be achieved by following the recommenda- tions of Approved Document ‘J’. These are as shown in Figure 11.

ST486a

at least

 

3 x D

D

 

at

leastD

x

 

3

at least 1.5 x D

at least 3 x D

Fluepipe Manual background

D

 

at least

 

1.5 x D

 

 

 

 

 

 

 

 

 

 

 

 

at least 1.5 x D

at least 1.5 x D

at least 1.5 x D

Elevation

Without

Shield

Fig. 11 Connecting fluepipe clearances.

 

Air space of at least 12 mm

Plan Without

between noncombustible shield

Shield

and combustible material

 

Plan With

Elevation

Shield

With Shield

ST911

 

10

2000970

Image 10
Contents Installation Multi-FuelHeaterModel 1695CE The IntrepidVermont Castings Intrepid Multi-Fuel Table of ContentsWelcome All of us at CFM CorporationVermont Castings Intrepid Multi-Fuel SpecificationsIntrepid Multi-Fuel,Model 1695CE, 1696CE, 1697CE 2000970What Kind of Chimney to Use InstallationOutside Air Vermont Castings Intrepid Multi-FuelMasonry Chimneys Chimney Connector GuidelinesDouble-wallChimney Connector Prefabricated ChimneysFreestanding Chimney Installations Single-wallChimney ConnectorSecuring the Single-wallConnector to a Prefabricated ChimneyThrough a Fireplace Fireplace Chimney Installations Above a FireplaceFireplace Chimney Installations Wall Pass-ThroughsVermont Castings Intrepid Multi-Fuel Floor Protection for Fireplace InstallationsHearths 2000970Clearances Keep the Stove a Safe Distancefrom Surrounding Materials Summary of ClearancesVermont Castings Intrepid Multi-Fuel Connecting Flue Pipe - Clearances2000970 Set Up the Stove AssemblyClean the Griddle Before Use Install the Bottom Heat ShieldIntrepid Multi-fuel’sControls OperationAttach the Griddle Handle Primary Air ControlTwo Ways to Add Fuel Glass Door PanelsFront Grate Vermont Castings Intrepid Multi-FuelIntrepid Multi-FuelControl Settings How to Build a Wood Fire and Keep It GoingConditioning Your Stove Vermont Castings Intrepid Multi-FuelVermont Castings Intrepid Multi-Fuel Refuel While the Embers Are Still HotAsh Disposal 2000970Indoor/Outdoor location Draft ManagementSteel Chimney Flue sizingBackpuffing Draft TestingFuel Negative PressureGlass Replacement MaintenanceCleaning the Glass Care of the Cast Iron SurfaceTighten the Damper Handle as Needed How to Adjust the Door LatchDamper Adjustment Replace the Stove Gaskets as NeededVermont Castings Intrepid Multi-Fuel Adjust the Door if NecessaryPermanent Gaskets 2000970Creosote Annual MaintenanceThe Chimney System Vermont Castings Intrepid Multi-FuelVermont Castings Intrepid Multi-Fuel Intrepid Multi-FuelHeaterModel 1695CE 2000970Vermont Castings Intrepid Multi-Fuel Intrepid Multi-FuelHeaterModel 1695CE continued 2000970Model 1695CE continued Intrepid Multi-FuelHeaterVermont Castings Intrepid Multi-Fuel Shell Enamel Parts - Intrepid Multi-FuelVermont Castings Intrepid Multi-Fuel 2000970Vermont Castings Intrepid Multi-Fuel 2000970Limited 1 Year Warranty WarrantyLimited 3 Year Warranty Limited Catalyst WarrantyCFM Corporation