Vermont Casting 1695CE Adjust the Door if Necessary, Permanent Gaskets, 2000970

Page 20
Adjust the Door if Necessary

Vermont Castings Intrepid Multi-Fuel

Wait until the fire is out and the stove has cooled. Be sure to follow the standard safety procedure for working with dusty materials: Wear safety goggles and a dust mask.

The procedure for replacing the gaskets is the same, regardless of the gasket location.

1.Remove the existing gasket by grasping an end and pulling firmly.

2.Use a wire brush or a screwdriver to clean the channel of any remaining cement or bits of gasket. Remove stubborn deposits of cement with a cold chisel if necessary. (Fig. 29)

 

ST560

Fig. 29

Remove gasket then clean channel with wire brush.

3.Determine the correct length of the appropriate-sized gasket by laying it out in the channel. Allow an extra 25-51 mm (1-2”) and mark the spot to be cut.

4.Remove the gasket from the channel, place it on a wood cutting surface, and cut it at the marked spot with a utility knife. Twist the ends slightly to keep the gasket from unraveling.

5.Lay an unbroken 3 mm (1/8”) bead of gasket cement in the newly-cleaned channel. Starting at one end, press the gasket into the channel. Ensure a good joint where the gasket meets before trimming any excess. Do not overlap the gasket ends or leave ends with ragged edges. (Fig. 30)

6.Press the gasketed part firmly against its normal mating surface to seat the gasket evenly in its chan- nel.

 

Gasket

 

ve

 

Sto Cement

 

ST561

Fig. 30

Lay a bead of gasket cement then press new gasket

in place.

7.For doors, replace the doors and close them on a piece of waxed paper to keep the cement from migrating onto the stove front, or tap other parts with the rubber mallet (or hammer/block of wood).

8.Clean excess cement from around the channel. Let the cement that holds the new gasket dry thoroughly.

Adjust the Door if Necessary

The door latch or damper mechanism may need adjust- ment after you have regasketed them. Initially, it may require loosening to accommodate the new gasket; af- ter a few weeks, it may need tightening to compensate for compression of the new gasket. The directions for adjusting the latch and damper handle are on Page 19.

Permanent Gaskets

Other gaskets seal between non-moving parts, but these are not subject to the same wear and deteriora- tion as gaskets on moving parts. It is unlikely that you will ever need to replace these gaskets unless the involved parts are disassembled and then put back together. If this is the case, the job should be done only by a qualified service technician. The diameter of the gasket that seals these non-moving parts is 5/16”, and the areas sealed are the flue collar to the stove back; and the lower fireback to the sides. Refer to Page 18 for information on the glass panels and their gaskets.

20

2000970

Image 20
Contents Multi-FuelHeater Model 1695CEInstallation The IntrepidTable of Contents WelcomeVermont Castings Intrepid Multi-Fuel All of us at CFM CorporationSpecifications Intrepid Multi-Fuel,Model 1695CE, 1696CE, 1697CEVermont Castings Intrepid Multi-Fuel 2000970Installation Outside AirWhat Kind of Chimney to Use Vermont Castings Intrepid Multi-FuelChimney Connector Guidelines Double-wallChimney ConnectorMasonry Chimneys Prefabricated ChimneysSingle-wallChimney Connector Securing the Single-wallConnector to aFreestanding Chimney Installations Prefabricated ChimneyFireplace Chimney Installations Above a Fireplace Fireplace Chimney InstallationsThrough a Fireplace Wall Pass-ThroughsFloor Protection for Fireplace Installations HearthsVermont Castings Intrepid Multi-Fuel 2000970Keep the Stove a Safe Distance from Surrounding MaterialsClearances Summary of Clearances2000970 Connecting Flue Pipe - ClearancesVermont Castings Intrepid Multi-Fuel Assembly Clean the Griddle Before UseSet Up the Stove Install the Bottom Heat ShieldOperation Attach the Griddle HandleIntrepid Multi-fuel’sControls Primary Air ControlGlass Door Panels Front GrateTwo Ways to Add Fuel Vermont Castings Intrepid Multi-FuelHow to Build a Wood Fire and Keep It Going Conditioning Your StoveIntrepid Multi-FuelControl Settings Vermont Castings Intrepid Multi-FuelRefuel While the Embers Are Still Hot Ash DisposalVermont Castings Intrepid Multi-Fuel 2000970Draft Management Steel ChimneyIndoor/Outdoor location Flue sizingDraft Testing FuelBackpuffing Negative PressureMaintenance Cleaning the GlassGlass Replacement Care of the Cast Iron SurfaceHow to Adjust the Door Latch Damper AdjustmentTighten the Damper Handle as Needed Replace the Stove Gaskets as NeededAdjust the Door if Necessary Permanent GasketsVermont Castings Intrepid Multi-Fuel 2000970Annual Maintenance The Chimney SystemCreosote Vermont Castings Intrepid Multi-FuelIntrepid Multi-FuelHeater Model 1695CEVermont Castings Intrepid Multi-Fuel 2000970Intrepid Multi-FuelHeater Model 1695CE continuedVermont Castings Intrepid Multi-Fuel 2000970Intrepid Multi-FuelHeater Vermont Castings Intrepid Multi-FuelModel 1695CE continued Shell Enamel Parts - Intrepid Multi-FuelVermont Castings Intrepid Multi-Fuel 2000970Vermont Castings Intrepid Multi-Fuel 2000970Warranty Limited 3 Year WarrantyLimited 1 Year Warranty Limited Catalyst WarrantyCFM Corporation