Vanguard Heating VMH3000TNSA Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 19).

2.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 20). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

ShutoffOpen

Valve

Closed

Figure 19 - Equipment Shutoff Valve

Gas Meter

Figure 20 - Checking Gas Joints

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 19).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 20). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 and 15). Check all other in- ternal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 14).

8.Replace front panel.

Thermostat Gas

Valve Location

Equipment

Shutoff Valve

107101

13

For more information, visit www.desatech.com

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualLocal Codes Safety InformationProduct Features AssemblyProduct Identification UnpackingAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater to Optional Hearth Base Mounting Heater on Optional Hearth BaseSecuring Hearth Base to Floor Mounting Heater to Optional Mantel Connecting to GAS SupplyAssembling Mantel Pressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To AppliancePilot Flame Pattern Inspecting BurnerBurner Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceService Hints VMH3000TNSA Illustrated Parts BreakdownKEY VMH3000TNSA Description QTY Parts ListTechnical Service SpecificationsAccessories International Warranty Information

VMH3000TNSA specifications

The Vanguard Heating VMH3000TNSA is a state-of-the-art heating solution designed to provide optimal warmth and comfort in various settings. This model, part of Vanguard's advanced heating line, stands out with its impressive blend of efficiency, technology, and user-friendly features.

One of the key highlights of the VMH3000TNSA is its powerful heating capacity. The unit is capable of delivering up to 3000 watts, making it suitable for larger spaces. This high output ensures that even in the coldest climates, users can enjoy a consistently warm environment. Its ability to rapidly heat up a room is a significant advantage, especially during the winter months.

Efficiency is another crucial feature of the VMH3000TNSA. It incorporates advanced heating technology that maximizes energy consumption. The unit is designed to provide heat with minimal energy use, thus helping to reduce electricity bills while still maintaining a comfortable temperature. This eco-friendly approach is perfect for those who are looking to minimize their environmental footprint without compromising on comfort.

The VMH3000TNSA is equipped with an intelligent digital thermostat that allows for precise temperature control. Users can easily set their desired temperature and let the unit automatically adjust its output to maintain that level. This feature not only enhances convenience but also contributes to energy savings, ensuring that the heater does not overwork itself.

Safety is a paramount concern with any heating device, and the Vanguard VMH3000TNSA does not disappoint. It features a built-in safety shut-off mechanism that automatically turns the unit off if it overheats. Additionally, the design includes cool-touch technology, ensuring that the exterior of the heater remains safe to touch, preventing accidental burns.

The unit is designed for ease of use and portability. It comes with integrated handles and a lightweight construction, allowing users to effortlessly move the heater from one room to another. This flexibility is particularly beneficial for individuals who want to heat specific areas of their home without having to invest in multiple heaters.

In terms of design, the VMH3000TNSA boasts a modern and sleek appearance that fits seamlessly into any home decor. Its compact size means it doesn’t take up much space, making it ideal for apartments and smaller homes.

Overall, the Vanguard Heating VMH3000TNSA is a top-tier heating solution that excels in performance, efficiency, safety, and design. Whether you are looking to heat a large living space or need a reliable unit for your office, the VMH3000TNSA stands as a versatile and effective choice to keep you warm throughout the colder months.