Vanguard Heating VMH3000TNSA Inspecting Burner, Pilot Flame Pattern, Burner Flame Pattern

Page 15

OWNER’S MANUAL

OPERATING

HEATER

Continued

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this heater differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or de- creases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 2, page 3).

2.Follow steps 1 through 5 under Light- ing Instructions, page 14.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, page 14.

5.Replace front panel.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 24

turn heater off (see To Turn Off Gas to Appliance, page 14)

seeTroubleshooting, pages 16 through 18

Thermocouple

Pilot Burner

Figure 23 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 24 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.

Note: When using the heater the first time, the flame will be yellow for approximately one hour until the log cures.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If burner flame pat- tern shows yellow tipping, follow instructions, bottom of this page.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas to Appliance, page 14)

seeTroubleshooting, pages 16 through 18

Top of Flame Even

With Top of Log

Figure 25 - Correct Burner Flame Pattern

Yellow Tipping

Figure 26 - Incorrect Burner Flame Pattern

107101

15

For more information, visit www.desatech.com

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualLocal Codes Safety InformationUnpacking AssemblyProduct Features Product IdentificationAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeInstallation Options Thermostat Sensing BulbMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Mounting Heater to Optional Hearth BaseSecuring Hearth Base to Floor Connecting to GAS Supply Mounting Heater to Optional MantelAssembling Mantel Pressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsInspecting Burner Pilot Flame PatternBurner Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsService Hints VMH3000TNSA Illustrated Parts BreakdownKEY VMH3000TNSA Description QTY Parts ListTechnical Service SpecificationsAccessories International Warranty Information

VMH3000TNSA specifications

The Vanguard Heating VMH3000TNSA is a state-of-the-art heating solution designed to provide optimal warmth and comfort in various settings. This model, part of Vanguard's advanced heating line, stands out with its impressive blend of efficiency, technology, and user-friendly features.

One of the key highlights of the VMH3000TNSA is its powerful heating capacity. The unit is capable of delivering up to 3000 watts, making it suitable for larger spaces. This high output ensures that even in the coldest climates, users can enjoy a consistently warm environment. Its ability to rapidly heat up a room is a significant advantage, especially during the winter months.

Efficiency is another crucial feature of the VMH3000TNSA. It incorporates advanced heating technology that maximizes energy consumption. The unit is designed to provide heat with minimal energy use, thus helping to reduce electricity bills while still maintaining a comfortable temperature. This eco-friendly approach is perfect for those who are looking to minimize their environmental footprint without compromising on comfort.

The VMH3000TNSA is equipped with an intelligent digital thermostat that allows for precise temperature control. Users can easily set their desired temperature and let the unit automatically adjust its output to maintain that level. This feature not only enhances convenience but also contributes to energy savings, ensuring that the heater does not overwork itself.

Safety is a paramount concern with any heating device, and the Vanguard VMH3000TNSA does not disappoint. It features a built-in safety shut-off mechanism that automatically turns the unit off if it overheats. Additionally, the design includes cool-touch technology, ensuring that the exterior of the heater remains safe to touch, preventing accidental burns.

The unit is designed for ease of use and portability. It comes with integrated handles and a lightweight construction, allowing users to effortlessly move the heater from one room to another. This flexibility is particularly beneficial for individuals who want to heat specific areas of their home without having to invest in multiple heaters.

In terms of design, the VMH3000TNSA boasts a modern and sleek appearance that fits seamlessly into any home decor. Its compact size means it doesn’t take up much space, making it ideal for apartments and smaller homes.

Overall, the Vanguard Heating VMH3000TNSA is a top-tier heating solution that excels in performance, efficiency, safety, and design. Whether you are looking to heat a large living space or need a reliable unit for your office, the VMH3000TNSA stands as a versatile and effective choice to keep you warm throughout the colder months.