Vanguard Heating VMH3000TNSA Check GAS Type, Installation Items, Locating Heater

Page 8

®

NATURAL GAS RESIDENTIAL HEATERS

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

ground joint union

test gauge connection *

LOCATING HEATER

WARNING: Maintain the mini- mum clearances shown in Figure

9.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.

You can locate heater on floor. The op- tional hearth base is needed. You can also install optional decorative mantels on the heater (some mantels require the hearth base). IMPORTANT: Only use optional mantels and hearth base specified in this manual. Purchase the optional mantel and hearth base from your dealer. See Accesso- ries, page 23.

The heater may also be mounted on a wall. You cannot use optional mantel if mounting heater on a wall.

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CEILING

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 5 through 7.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor.

locate heater where moving ve- hicle will not hit it.

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service.

in coldest part of room.

An optional fan kit is available from your dealer. See Accessories, page 23. If plan- ning to use fan, locate heater near an electri- cal outlet.

sediment trap

tee joint

pipe wrench

6" Minimum From Sides Of Heater

36"

Minimum

*An CSA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA design- certified equipment shutoff valve from your dealer. See Accessories, page 23.

Left

Right

Side

Side

 

Minimum to

 

Top Surface

 

3" of Carpeting,

FLOOR

Tile, or Other

Combustible

 

 

Material

Figure 9 - Mounting Clearances As Viewed From Front of Heater

For more information, visit www.desatech.com

8

107101

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Local CodesAssembly Product FeaturesProduct Identification UnpackingAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ItemsCheck GAS Type Locating HeaterMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Installing Bottom Mounting Screws Placing Heater On Mounting BracketSecuring Hearth Base to Floor Mounting Heater on Optional Hearth BaseMounting Heater to Optional Hearth Base Assembling Mantel Connecting to GAS SupplyMounting Heater to Optional Mantel Checking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To ApplianceBurner Flame Pattern Inspecting BurnerPilot Flame Pattern Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Service Hints Cleaning and MaintenanceReplacement Parts Illustrated Parts Breakdown VMH3000TNSAParts List KEY VMH3000TNSA Description QTYSpecifications Technical ServiceAccessories Warranty Information International

VMH3000TNSA specifications

The Vanguard Heating VMH3000TNSA is a state-of-the-art heating solution designed to provide optimal warmth and comfort in various settings. This model, part of Vanguard's advanced heating line, stands out with its impressive blend of efficiency, technology, and user-friendly features.

One of the key highlights of the VMH3000TNSA is its powerful heating capacity. The unit is capable of delivering up to 3000 watts, making it suitable for larger spaces. This high output ensures that even in the coldest climates, users can enjoy a consistently warm environment. Its ability to rapidly heat up a room is a significant advantage, especially during the winter months.

Efficiency is another crucial feature of the VMH3000TNSA. It incorporates advanced heating technology that maximizes energy consumption. The unit is designed to provide heat with minimal energy use, thus helping to reduce electricity bills while still maintaining a comfortable temperature. This eco-friendly approach is perfect for those who are looking to minimize their environmental footprint without compromising on comfort.

The VMH3000TNSA is equipped with an intelligent digital thermostat that allows for precise temperature control. Users can easily set their desired temperature and let the unit automatically adjust its output to maintain that level. This feature not only enhances convenience but also contributes to energy savings, ensuring that the heater does not overwork itself.

Safety is a paramount concern with any heating device, and the Vanguard VMH3000TNSA does not disappoint. It features a built-in safety shut-off mechanism that automatically turns the unit off if it overheats. Additionally, the design includes cool-touch technology, ensuring that the exterior of the heater remains safe to touch, preventing accidental burns.

The unit is designed for ease of use and portability. It comes with integrated handles and a lightweight construction, allowing users to effortlessly move the heater from one room to another. This flexibility is particularly beneficial for individuals who want to heat specific areas of their home without having to invest in multiple heaters.

In terms of design, the VMH3000TNSA boasts a modern and sleek appearance that fits seamlessly into any home decor. Its compact size means it doesn’t take up much space, making it ideal for apartments and smaller homes.

Overall, the Vanguard Heating VMH3000TNSA is a top-tier heating solution that excels in performance, efficiency, safety, and design. Whether you are looking to heat a large living space or need a reliable unit for your office, the VMH3000TNSA stands as a versatile and effective choice to keep you warm throughout the colder months.