Vanguard Heating VMH3000TNSA installation manual Thermostat Sensing Bulb, Installation Options

Page 9

OWNER’S MANUAL

INSTALLATION

Continued

THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed insidetheheaterforprotectionduringshipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Fig- ure 2, page 3).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 10. Clamp is pro- vided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 10. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat

Sensing Bulb

Clamp

Figure 10 - Attaching Thermostat Sens- ing Bulb

INSTALLATION OPTIONS

There are three options for mounting this heater.

A.Mounting heater to wall

B.Mounting heater to optional hearth base

C.Mounting heater to optional mantel (some mantels require the hearth base)

A. MOUNTING HEATER TO WALL

Mounting Bracket

The mounting bracket is located in the pack- age tray. Remove mounting bracket from tray.

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching To Wall Stud: This method pro- vides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching To Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 11. If you can, provide greater clear- ances from floor and joining wall.

2.Mark screw locations on wall (see Fig- ure 11).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

18 3/4"

Screws Through Last

Min.

Hole On Each End

 

Floor

Figure 11 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs.

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Continued

107101

9

For more information, visit www.desatech.com

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualLocal Codes Safety InformationProduct Features AssemblyProduct Identification UnpackingAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterInstallation Options Thermostat Sensing BulbMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Mounting Heater to Optional Hearth BaseSecuring Hearth Base to Floor Connecting to GAS Supply Mounting Heater to Optional MantelAssembling Mantel Pressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Pilot Flame PatternBurner Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsService Hints VMH3000TNSA Illustrated Parts BreakdownKEY VMH3000TNSA Description QTY Parts ListTechnical Service SpecificationsAccessories International Warranty Information

VMH3000TNSA specifications

The Vanguard Heating VMH3000TNSA is a state-of-the-art heating solution designed to provide optimal warmth and comfort in various settings. This model, part of Vanguard's advanced heating line, stands out with its impressive blend of efficiency, technology, and user-friendly features.

One of the key highlights of the VMH3000TNSA is its powerful heating capacity. The unit is capable of delivering up to 3000 watts, making it suitable for larger spaces. This high output ensures that even in the coldest climates, users can enjoy a consistently warm environment. Its ability to rapidly heat up a room is a significant advantage, especially during the winter months.

Efficiency is another crucial feature of the VMH3000TNSA. It incorporates advanced heating technology that maximizes energy consumption. The unit is designed to provide heat with minimal energy use, thus helping to reduce electricity bills while still maintaining a comfortable temperature. This eco-friendly approach is perfect for those who are looking to minimize their environmental footprint without compromising on comfort.

The VMH3000TNSA is equipped with an intelligent digital thermostat that allows for precise temperature control. Users can easily set their desired temperature and let the unit automatically adjust its output to maintain that level. This feature not only enhances convenience but also contributes to energy savings, ensuring that the heater does not overwork itself.

Safety is a paramount concern with any heating device, and the Vanguard VMH3000TNSA does not disappoint. It features a built-in safety shut-off mechanism that automatically turns the unit off if it overheats. Additionally, the design includes cool-touch technology, ensuring that the exterior of the heater remains safe to touch, preventing accidental burns.

The unit is designed for ease of use and portability. It comes with integrated handles and a lightweight construction, allowing users to effortlessly move the heater from one room to another. This flexibility is particularly beneficial for individuals who want to heat specific areas of their home without having to invest in multiple heaters.

In terms of design, the VMH3000TNSA boasts a modern and sleek appearance that fits seamlessly into any home decor. Its compact size means it doesn’t take up much space, making it ideal for apartments and smaller homes.

Overall, the Vanguard Heating VMH3000TNSA is a top-tier heating solution that excels in performance, efficiency, safety, and design. Whether you are looking to heat a large living space or need a reliable unit for your office, the VMH3000TNSA stands as a versatile and effective choice to keep you warm throughout the colder months.