Vanguard Heating WMH26TNB Attaching Wood Base to Solid Floor, Connecting to GAS Supply

Page 14

14

INSTALLATION

Installing Blower Accessory - GA3450T (Cont.) Attaching Wood Base to Solid Floor Connecting to Gas Supply

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

ATTACHING WOOD BASE TO SOLID FLOOR

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 22.

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fastened to floor.

Figure 22 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 45° male flare fitting 5/8"-18 UNF (Unified National Fine Thread) inlet connection and the flexible gas line provided.

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 23. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Propane/LP

Supply Tank

External Regulator

Vent Pointing Down

Figure 23 - External Regulator with Vent Pointing Down

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 24, page 15).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

For..com

111043-01A

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLocal Codes Product IdentificationUnpacking Product FeaturesAssembly Assembling Hood AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsLocating Fireplace Installation ItemsCheck GAS Type BUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass Trim Shipped with Mantel Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Installing Blower Assembly Removing Valve Cover ShieldFor Built-In Installation OutletExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Replacement Parts SpecificationsService Hints Technical ServiceIllustrated Parts Breakdown VMH26TNBParts List KEY VMH26TPB VMH26TNB Description QTYAccessories Owners Registration Form Postage Required 111043-01A Warranty Information

WMH26TNB specifications

The Vanguard Heating WMH26TNB is a powerful and efficient heating solution designed to meet the needs of residential spaces. This heating unit stands out for its innovative technology, robust features, and reliability, making it a preferred choice for homeowners looking to maintain a comfortable environment during colder months.

One of the main features of the WMH26TNB is its impressive heating capacity. With an output that can effectively warm spaces up to 1,000 square feet, it ensures consistent and uniform heat distribution throughout the room. This makes it an ideal option for living rooms, bedrooms, and even larger areas, providing a cozy atmosphere for family gatherings and quiet evenings.

Equipped with advanced heating technology, the WMH26TNB utilizes high-efficiency heating elements that minimize energy consumption while maximizing output. This not only helps in reducing electricity bills but also contributes to environmental sustainability. The unit's Energy Star certification further underscores its commitment to energy efficiency, allowing homeowners to enjoy warmth without compromise.

Another notable characteristic of the Vanguard WMH26TNB is its user-friendly digital thermostat. This intuitive interface allows for precise temperature control and programming, enabling users to set their heating preferences with ease. The programmable functionality means that users can schedule heating times based on their daily routines, ensuring that the space is warm when they need it most, without wasting energy when it's not.

The design of the WMH26TNB is both functional and aesthetically pleasing. Its sleek, modern look allows it to blend seamlessly with various home decors. The unit is also compact, making it easy to install in tight spaces, and it features a durable housing that can withstand the rigors of daily use.

Safety is paramount in any heating appliance, and the WMH26TNB does not disappoint. It includes multiple safety features, such as overheat protection and tip-over shutoff, giving users peace of mind when the unit is in operation.

In summary, the Vanguard Heating WMH26TNB is a versatile heating solution that combines advanced technology, efficient performance, and user-friendly features. Its capacity to efficiently heat large spaces, coupled with energy-saving capabilities, makes it a reliable choice for homeowners seeking warmth and comfort. Whether for everyday use or special occasions, the WMH26TNB stands as a testament to Vanguard's commitment to quality and innovation in heating solutions.