CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspection, and service.

in coldest part of room.

An optional blower kit is available from your dealer (see Accesso- ries, page 26). If planning to use blower, locate fireplace near an electrical outlet.

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accessories, page 26). Brass trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace you must follow the clearances shown in Figure 12, page 10. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

9 1/2"

10 1/2"

Bottom

3/4"

3/4"

1.Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening.

If installing in a corner, use dimensions shown in Figure 10 for the rough opening. The height is 26 7/8" which is the same as the wall opening above.

WARNING: If pre-wiring, do not connect wiring to any electrical source at this time.

Install fireplace electrical outlet and connect wiring to outlet before connecting to electrical source. The fireplace electrical outlet is included with the GA3450T blower accessory.

Only use the fireplace electrical outlet supplied with the GA3450T blower accessory.

2.If installing GA3450T blower accessory, do so at this time. See Installing Blower Accessory GA3450T, page 11.

Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installa- tion (see Accessories, page 26) Use only approved three-wire electrical wiring.

Note:A qualified installer should make all electrical connections.

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping.

4.If you have not assembled firebox, follow instructions on page 4.

5.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

6.Attach flexible gas line to fireplace gas regulator. See Con- necting Fireplace to Gas Supply, page 15.

7.Bend four nailing flanges on outer casing with pliers (see Figure 11, page 10).

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.

9.Check all gas connections for leaks. See Checking Gas Con- nections, page 16.

10 1/2"

267/8"

3/4" Off

The Floor

267/8" Minimum

Figure 9 - Rough Opening for Installing in Wall

365/8"

257/8"

267/8" 513/4"

Figure 10 - Rough Opening for Installing in Corner

For morevisit www..com

111043-01A

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Local CodesProduct Features AssemblyUnpacking Providing Adequate Ventilation AIR for Combustion and VentilationAssembling Hood Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Fireplace Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationInstalling Blower Accessory GA3450T Removing Upper Louver AssemblyAssembling Brass Trim Brass Trim Shipped with Mantel Removing Valve Cover Shield Installing Blower AssemblyOutlet For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceBurner Flame Pattern CabinetObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Service Hints SpecificationsReplacement Parts Technical ServiceVMH26TNB Illustrated Parts BreakdownKEY VMH26TPB VMH26TNB Description QTY Parts ListAccessories Owners Registration Form Postage Required 111043-01A Warranty Information

WMH26TNB specifications

The Vanguard Heating WMH26TNB is a powerful and efficient heating solution designed to meet the needs of residential spaces. This heating unit stands out for its innovative technology, robust features, and reliability, making it a preferred choice for homeowners looking to maintain a comfortable environment during colder months.

One of the main features of the WMH26TNB is its impressive heating capacity. With an output that can effectively warm spaces up to 1,000 square feet, it ensures consistent and uniform heat distribution throughout the room. This makes it an ideal option for living rooms, bedrooms, and even larger areas, providing a cozy atmosphere for family gatherings and quiet evenings.

Equipped with advanced heating technology, the WMH26TNB utilizes high-efficiency heating elements that minimize energy consumption while maximizing output. This not only helps in reducing electricity bills but also contributes to environmental sustainability. The unit's Energy Star certification further underscores its commitment to energy efficiency, allowing homeowners to enjoy warmth without compromise.

Another notable characteristic of the Vanguard WMH26TNB is its user-friendly digital thermostat. This intuitive interface allows for precise temperature control and programming, enabling users to set their heating preferences with ease. The programmable functionality means that users can schedule heating times based on their daily routines, ensuring that the space is warm when they need it most, without wasting energy when it's not.

The design of the WMH26TNB is both functional and aesthetically pleasing. Its sleek, modern look allows it to blend seamlessly with various home decors. The unit is also compact, making it easy to install in tight spaces, and it features a durable housing that can withstand the rigors of daily use.

Safety is paramount in any heating appliance, and the WMH26TNB does not disappoint. It includes multiple safety features, such as overheat protection and tip-over shutoff, giving users peace of mind when the unit is in operation.

In summary, the Vanguard Heating WMH26TNB is a versatile heating solution that combines advanced technology, efficient performance, and user-friendly features. Its capacity to efficiently heat large spaces, coupled with energy-saving capabilities, makes it a reliable choice for homeowners seeking warmth and comfort. Whether for everyday use or special occasions, the WMH26TNB stands as a testament to Vanguard's commitment to quality and innovation in heating solutions.