INSTALLATION

Connecting to Gas Supply (Cont.) Connecting Equipment Shutoff Valve to Heater Control

15

INSTALLATION

Continued

We recommend that you install a sediment trap in supply line as shown in Figure 24. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

4.

Apply pipe joint sealant lightly to male threads of gas connec-

 

tor attached to flexible gas line/equipment shutoff valve (see

 

Figure 26).

5.

Check all gas connections for leaks. See Checking Gas Con-

 

nections, page 16.

6.

Replace branch support back into fireplace. Feed flexible gas

 

line into fireplace base area while replacing branch support.

 

Make sure the entire flexible gas line is in fireplace base area.

 

Reattach branch support to fireplace with screws removed in

 

step 2.

3" Minimum

PROPANE/LP

From External Regulator (11" W.C. to 14" W.C. Pressure)

Branch

Screen Shipping

Pipe Cap Nipple

Tee

NATURAL

From Gas Meter (5" W.C.

Joint

to 10.5" W.C. Pressure)

 

Support

Screw

Shoulder

Sediment Trap

Figure 24 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1. Remove fireplace screen. Remove two screws that hold fire-

place screen in place for shipping. These screws are located

Screw

Flexible

Gas Line

Screen

Figure 25 - Removing Log Base Assembly From Fireplace

near top of screen. Discard screws. Lift fireplace screen up

and pull out to remove.

2. Remove screws that attach branch support to fireplace (see

Figure 25). Carefully lift up branch support and remove from

fireplace (see Figure 25).

3. Route flexible gas line included from fireplace control to equip-

ment shutoff valve through side or rear access holes in outer casing.

NOTICE: Most building codes do not permit con- cealed gas connections. A flexible gas line is pro- vided to allow accessibility from the fireplace (see

To Fireplace

Gas Regulator

Flexible Gas Line from Fireplace Gas Regulator Provided with Fireplace

Equipment Shutoff Valve Provided by Installer

PROPANE/LP

To External

Regulator

NATURAL

To Gas Supply

Figure 25). The flexible gas supply line connection to the equipment shutoff valve should be accessible.

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff Valve

For morevisit www..com

111043-01A

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Local CodesProduct Features AssemblyUnpacking Unusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Assembling HoodDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingInstallation Items Check GAS TypeLocating Fireplace Rough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationInstalling Blower Accessory GA3450T Removing Upper Louver AssemblyAssembling Brass Trim Brass Trim Shipped with Mantel Removing Valve Cover Shield Installing Blower AssemblyOutlet For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorExtension Cord Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Cabinet Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Technical Service SpecificationsService Hints Replacement PartsVMH26TNB Illustrated Parts BreakdownKEY VMH26TPB VMH26TNB Description QTY Parts ListAccessories Owners Registration Form Postage Required 111043-01A Warranty Information

WMH26TNB specifications

The Vanguard Heating WMH26TNB is a powerful and efficient heating solution designed to meet the needs of residential spaces. This heating unit stands out for its innovative technology, robust features, and reliability, making it a preferred choice for homeowners looking to maintain a comfortable environment during colder months.

One of the main features of the WMH26TNB is its impressive heating capacity. With an output that can effectively warm spaces up to 1,000 square feet, it ensures consistent and uniform heat distribution throughout the room. This makes it an ideal option for living rooms, bedrooms, and even larger areas, providing a cozy atmosphere for family gatherings and quiet evenings.

Equipped with advanced heating technology, the WMH26TNB utilizes high-efficiency heating elements that minimize energy consumption while maximizing output. This not only helps in reducing electricity bills but also contributes to environmental sustainability. The unit's Energy Star certification further underscores its commitment to energy efficiency, allowing homeowners to enjoy warmth without compromise.

Another notable characteristic of the Vanguard WMH26TNB is its user-friendly digital thermostat. This intuitive interface allows for precise temperature control and programming, enabling users to set their heating preferences with ease. The programmable functionality means that users can schedule heating times based on their daily routines, ensuring that the space is warm when they need it most, without wasting energy when it's not.

The design of the WMH26TNB is both functional and aesthetically pleasing. Its sleek, modern look allows it to blend seamlessly with various home decors. The unit is also compact, making it easy to install in tight spaces, and it features a durable housing that can withstand the rigors of daily use.

Safety is paramount in any heating appliance, and the WMH26TNB does not disappoint. It includes multiple safety features, such as overheat protection and tip-over shutoff, giving users peace of mind when the unit is in operation.

In summary, the Vanguard Heating WMH26TNB is a versatile heating solution that combines advanced technology, efficient performance, and user-friendly features. Its capacity to efficiently heat large spaces, coupled with energy-saving capabilities, makes it a reliable choice for homeowners seeking warmth and comfort. Whether for everyday use or special occasions, the WMH26TNB stands as a testament to Vanguard's commitment to quality and innovation in heating solutions.