Vanguard Heating FB32CA, FB32NCA Installing LOG Heater in Firebox, Installing Fireplace Hood

Page 12

INSTALLATION

Continued

INSTALLING LOG HEATER IN FIREBOX

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

1.Remove four screws holding firebox bottom in place.

2.Lift and remove firebox bottom (see Figure 13).

3.If installing GA3700 Blower Accessory (Models FB32CA and NLFB32C only), see Installing Blower Accessory, page 10.

4.Route flexible gas line from manual shutoff valve into firebox through side.

NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is recommended to allow ac- cessibility from the firebox. The flexible gas supply line connec- tion to the manual shutoff valve should be accessible.

5.Install and properly test gas log heater. Follow installation instructions included with the vent- free gas log heater that is being installed.

6.Replace firebox bottom and secure with screws.

Heater Base

Screws

Mounting

Bracket

to CutLength1/4" 7

Firebox

Bottom

Figure 14 - Cutting Brackets

INSTALLING FIREPLACE HOOD

NOTICE: The firebox canopy (hood) must not be modified or replaced with a canopy (hood) that maybeprovidedwiththeunvented decorative room heater.

1.Attach three zinc-colored shoulder screws to back of hood.

2.Insert hood into hood-mounting slots on firebox.

3.Hold hood in place. Insert two black Phillips screws through bottom of hood and tighten.

Hood

Hood

Mounting

Slot

Shoulder

Screw

Screw

Screws

Figure 15 - Installing Fireplace Hood

Figure 13 - Removing Firebox Bottom

12

www.desatech.com

105604-01H

Image 12
Contents Unvented VENT-FREE 32 LogMate Universal FireBOX Shown with optional cabinetTable of Contents Safety Information Product Specifications Local CodesUnpacking Product Features Blower AccessoryLocating Firebox OperationAIR for Combustion Ventilation Providing Adequate VentilationFollowing are excerpts from National Fuel Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Clearances Mantel Clearances for Built-In InstallationMinimum 16 inches from Side Wall Installing Blower Accessory Conventional Installation of Blower AccessoryModel FB32CA only Plug in blower power cord Built-In Installation of Blower AccessoryOperating the Blower Speed you desireInstalling LOG Heater in Firebox Installing Fireplace HoodRemove four screws holding firebox bottom in place Replace firebox bottom and secure with screwsInstalling Fireplace Screen Firebox Installation Using Optional Accessory MantelsTions are included with each accessory Route flexible gas line through access hole in hearth baseBUILT-IN Firebox Installation 27 7/8Replacement Parts Technical ServiceParts Under Warranty Parts not Under WarrantyAccessories Hardwood Cabinet Hearth Base Laminate Trim for Hearth or MantelIllustrated Parts Breakdown Models FB32NCA and NLFB32NCParts List Models FB32CA and NLFB32C KEY Part Number FB32CA NLFB32C Description QTY 105604-01H 105604-01H Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Firebox

NLFB32NC, NLFB32C, FB32CA, FB32NCA specifications

The Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C are modern, innovative heating systems crafted to meet the demands of contemporary living spaces. These models emphasize efficiency, reliability, and advanced technology, making them a popular choice for both residential and commercial applications.

One of the standout features of the Vanguard Heating line is its energy efficiency. Designed with cutting-edge technology, these heating units boast optimized heating performance while minimizing energy consumption. With a high energy efficiency rating, they help users reduce their carbon footprint and lower utility bills, providing a substantial return on investment over the years.

These models incorporate advanced heating technologies, including variable speed fans, which adjust according to the heating needs of the space. This feature not only enhances comfort by maintaining a consistent temperature but also reduces noise levels, allowing for a peaceful environment. The intuitive control systems enable users to easily adjust settings, ensuring that their heating preferences are met at all times.

Constructed with durable materials, the Vanguard Heating models are designed to withstand the rigors of daily use. Their robust build quality ensures longevity and reduces the need for frequent maintenance. Additionally, the compact design of these systems allows for flexible installation, making them suitable for a variety of settings, whether in tight spaces or larger areas.

Moreover, the NLFB32NC and its counterparts are equipped with safety features that prioritize user protection. Overheat protection and automatic shut-off mechanisms are standard, ensuring that the units operate safely and efficiently. These heating systems also come with easy-to-read digital displays, enabling users to monitor performance and troubleshoot any issues quickly.

The Vanguard Heating series is also designed with environmental considerations in mind. They comply with stringent environmental standards, contributing to a greener future. The use of sustainable materials in production further reflects Vanguard's commitment to eco-friendly practices.

In summary, the Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C offer a comprehensive heating solution characterized by energy efficiency, advanced heating technologies, durability, and safety features. Their innovative designs cater to a wide range of heating needs, making them an excellent choice for anyone seeking reliable, high-performance heating solutions. By choosing Vanguard Heating, users benefit from enhanced comfort, cost savings, and a reduced environmental impact.