Vanguard Heating FB32NCA, FB32CA Installation Clearances, Minimum 16 inches from Side Wall

Page 9

INSTALLATION

Continued

IMPORTANT: Vent-free gas log heaters add moisture to the air. Although this is beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

IMPORTANT: Make sure the firebox is level. If firebox is not level, log set will not work properly.

Note: Your Vanguard firebox is designed to be used in zero clearance installations. Wall or fram- ing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where standoff spacers are inte- grally attached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Firebox Installation, page 14).

Example

*

*Minimum 16 inches from Side Wall

Figure 6 - Minimum Clearance for

Combustible to Wall

Mantel Clearances for Built-In

Installation

If placing custom mantel above built-in firebox, you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 8. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel.

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

CAUTION: Close screens before operation of vent-free gas log heater. Do not allow the heater to touch or extend beyond the fireplace screen.

If your installation does not meet the minimum clearances in Figure 8, you must:

raise the mantel to an acceptable height, OR • remove the mantel.

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 6).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

 

 

 

42"

16"

0"

 

 

 

Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.

Facing material

 

 

 

Mantel Shelf

 

10"

 

 

 

 

(above firebox)

 

 

 

 

8"

 

 

 

 

 

may be of

 

 

 

 

 

 

 

 

 

 

 

 

combustible

6"

 

 

 

 

 

material, including

2 1/2"

 

 

 

 

decorative mantel

 

 

 

 

 

 

 

ornaments.

 

 

 

 

 

 

 

 

 

 

 

 

19"

20"

21"

22"

Firebox

 

 

 

13"

16"

19"

21"

Wire

-mesh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen

 

 

Supplied

 

 

 

 

 

 

 

Firebox Hood

 

 

 

 

 

 

 

 

 

 

 

 

Must Be Used

 

 

 

 

 

 

 

 

 

 

 

at All Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For FB32NCA and NLFB32NC Series noncirculating, smooth face models

For FB32CA and NLFB32C Series circulating, louvered models only

Figure 7 - Minimum Mantel Clearances

for Built-In Installation

105604-01H

www.desatech.com

9

Image 9
Contents Shown with optional cabinet Unvented VENT-FREE 32 LogMate Universal FireBOXTable of Contents Safety Information Product Specifications Local CodesUnpacking Blower Accessory Product FeaturesLocating Firebox OperationProviding Adequate Ventilation AIR for Combustion VentilationFollowing are excerpts from National Fuel Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Clearances Mantel Clearances for Built-In InstallationMinimum 16 inches from Side Wall Installing Blower Accessory Conventional Installation of Blower AccessoryModel FB32CA only Built-In Installation of Blower Accessory Plug in blower power cordOperating the Blower Speed you desireInstalling Fireplace Hood Installing LOG Heater in FireboxRemove four screws holding firebox bottom in place Replace firebox bottom and secure with screwsFirebox Installation Using Optional Accessory Mantels Installing Fireplace ScreenTions are included with each accessory Route flexible gas line through access hole in hearth base27 7/8 BUILT-IN Firebox InstallationTechnical Service Replacement PartsParts Under Warranty Parts not Under WarrantyAccessories Laminate Trim for Hearth or Mantel Hardwood Cabinet Hearth BaseModels FB32NCA and NLFB32NC Illustrated Parts BreakdownParts List Models FB32CA and NLFB32C KEY Part Number FB32CA NLFB32C Description QTY 105604-01H 105604-01H Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Firebox

NLFB32NC, NLFB32C, FB32CA, FB32NCA specifications

The Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C are modern, innovative heating systems crafted to meet the demands of contemporary living spaces. These models emphasize efficiency, reliability, and advanced technology, making them a popular choice for both residential and commercial applications.

One of the standout features of the Vanguard Heating line is its energy efficiency. Designed with cutting-edge technology, these heating units boast optimized heating performance while minimizing energy consumption. With a high energy efficiency rating, they help users reduce their carbon footprint and lower utility bills, providing a substantial return on investment over the years.

These models incorporate advanced heating technologies, including variable speed fans, which adjust according to the heating needs of the space. This feature not only enhances comfort by maintaining a consistent temperature but also reduces noise levels, allowing for a peaceful environment. The intuitive control systems enable users to easily adjust settings, ensuring that their heating preferences are met at all times.

Constructed with durable materials, the Vanguard Heating models are designed to withstand the rigors of daily use. Their robust build quality ensures longevity and reduces the need for frequent maintenance. Additionally, the compact design of these systems allows for flexible installation, making them suitable for a variety of settings, whether in tight spaces or larger areas.

Moreover, the NLFB32NC and its counterparts are equipped with safety features that prioritize user protection. Overheat protection and automatic shut-off mechanisms are standard, ensuring that the units operate safely and efficiently. These heating systems also come with easy-to-read digital displays, enabling users to monitor performance and troubleshoot any issues quickly.

The Vanguard Heating series is also designed with environmental considerations in mind. They comply with stringent environmental standards, contributing to a greener future. The use of sustainable materials in production further reflects Vanguard's commitment to eco-friendly practices.

In summary, the Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C offer a comprehensive heating solution characterized by energy efficiency, advanced heating technologies, durability, and safety features. Their innovative designs cater to a wide range of heating needs, making them an excellent choice for anyone seeking reliable, high-performance heating solutions. By choosing Vanguard Heating, users benefit from enhanced comfort, cost savings, and a reduced environmental impact.