Vanguard Heating NLFB32NC Plug in blower power cord, Built-In Installation of Blower Accessory

Page 11

INSTALLATION

Continued

7.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1/2" hole in the floor support on the exit side. Install the second plastic bushing provided into the 1 1/2" hole in the outer casing through which the power cord will exit (see Figure 11). Route power cord through both plastic bushings and plug the power cord into a 3-prong grounded wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, see Built-In Installation of Blower Accessory, column 2.

8.Turn on power to duplex outlet if previously turned off per the warning in step 1.

9.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation.

WARNING: Never touch the blower wheel while in operation.

10.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bottom approximately 12" in front of the blower.

11.Replace bottom of firebox. Note: Make sure the back of the firebox bottom slides under the rear of the firebrick (lift the firebrick up if necessary.)

12.Reattach firebox bottom using 4 screws re- moved in step 1. Note: Discard the remaining hardware items.

13.Install the log set heater according to the instal- lation instructions supplied with the heater.

Plastic

Bushing

Figure 11 - Installing Plastic Bushing for

Power Cord

NOTICE: A qualified electrician must connect electrical wiring to duplex outlet for built-in instal- lation. Follow all local codes. In absence of local codes follow The National Electrical Code ANSI/NFPA 70.

Built-In Installation of Blower Accessory

1.Before replacing bottom of firebox, remove screw holding duplex outlet to the support bracket in the bottom of firebox. Remove duplex outlet.

2.Clamp electrical cable into firebox through smallest hole in outer casing using strain relief provided.

3.Route wires from electrical box through hole in side of heater and hole in support bracket (see Figure 12).

4.Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire.

5.Replace duplex outlet with screw.

6.Plug blower power cord into duplex outlet.

7.Replace bottom of firebox.

 

Cables From

Support Bracket

Electrical Source

 

Blower

 

 

Duplex

 

Outlet

Blower

Screw

 

Power Cord

Figure 12 - Routing Blower Accessory

Power Cord for Built-In Installation

Operating the Blower

 

Light your gas appliance with the blower off. After

about 15 minutes, turn the blower on to deliver

heated air at the top louvers. The blower features

a variable control which allows you to select the

speed you desire.

 

Note: Periodically check the louvers of the firebox

and remove any dust, dirt, or other obstructions.

105604-01H

www.desatech.com

11

Image 11
Contents Shown with optional cabinet Unvented VENT-FREE 32 LogMate Universal FireBOXTable of Contents Safety Information Unpacking Product SpecificationsLocal Codes Operation Product FeaturesBlower Accessory Locating FireboxUnusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Following are excerpts from National FuelDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum 16 inches from Side Wall Installation ClearancesMantel Clearances for Built-In Installation Model FB32CA only Installing Blower AccessoryConventional Installation of Blower Accessory Speed you desire Plug in blower power cordBuilt-In Installation of Blower Accessory Operating the BlowerReplace firebox bottom and secure with screws Installing LOG Heater in FireboxInstalling Fireplace Hood Remove four screws holding firebox bottom in placeRoute flexible gas line through access hole in hearth base Installing Fireplace ScreenFirebox Installation Using Optional Accessory Mantels Tions are included with each accessory27 7/8 BUILT-IN Firebox InstallationParts not Under Warranty Replacement PartsTechnical Service Parts Under WarrantyAccessories Laminate Trim for Hearth or Mantel Hardwood Cabinet Hearth BaseModels FB32NCA and NLFB32NC Illustrated Parts BreakdownParts List Models FB32CA and NLFB32C KEY Part Number FB32CA NLFB32C Description QTY 105604-01H 105604-01H Limited Warranty VENT-FREE Firebox Warranty InformationKeep this Warranty

NLFB32NC, NLFB32C, FB32CA, FB32NCA specifications

The Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C are modern, innovative heating systems crafted to meet the demands of contemporary living spaces. These models emphasize efficiency, reliability, and advanced technology, making them a popular choice for both residential and commercial applications.

One of the standout features of the Vanguard Heating line is its energy efficiency. Designed with cutting-edge technology, these heating units boast optimized heating performance while minimizing energy consumption. With a high energy efficiency rating, they help users reduce their carbon footprint and lower utility bills, providing a substantial return on investment over the years.

These models incorporate advanced heating technologies, including variable speed fans, which adjust according to the heating needs of the space. This feature not only enhances comfort by maintaining a consistent temperature but also reduces noise levels, allowing for a peaceful environment. The intuitive control systems enable users to easily adjust settings, ensuring that their heating preferences are met at all times.

Constructed with durable materials, the Vanguard Heating models are designed to withstand the rigors of daily use. Their robust build quality ensures longevity and reduces the need for frequent maintenance. Additionally, the compact design of these systems allows for flexible installation, making them suitable for a variety of settings, whether in tight spaces or larger areas.

Moreover, the NLFB32NC and its counterparts are equipped with safety features that prioritize user protection. Overheat protection and automatic shut-off mechanisms are standard, ensuring that the units operate safely and efficiently. These heating systems also come with easy-to-read digital displays, enabling users to monitor performance and troubleshoot any issues quickly.

The Vanguard Heating series is also designed with environmental considerations in mind. They comply with stringent environmental standards, contributing to a greener future. The use of sustainable materials in production further reflects Vanguard's commitment to eco-friendly practices.

In summary, the Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C offer a comprehensive heating solution characterized by energy efficiency, advanced heating technologies, durability, and safety features. Their innovative designs cater to a wide range of heating needs, making them an excellent choice for anyone seeking reliable, high-performance heating solutions. By choosing Vanguard Heating, users benefit from enhanced comfort, cost savings, and a reduced environmental impact.