Vanguard Heating VP2000BTD installation manual OWNER’S Operation and Installation Manual

Page 1

®

BLUE FLAME

VENT-FREE PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

VP2000BTD

VP2800BTD

20,000 and 30,000 Btu/Hr

Thermostatically-

Controlled Models

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For as- sistance or additional information consult a qualified installer, ser- vice agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for ad- equate combustion and ventila- tion air must be provided. Refer to Air for Combustion and Venti- lation section on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualBlue Flame PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterInstalling Heater to Wall Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Replacement Parts SpecificationsAccessories Technical ServiceIllustrated Parts Breakdown ODS/Pilot AssemblyVP2000BTD VP2800BTD KEY Part Number for VP2000BTD VP2800BTD Description QTY Parts ListWarranty Information

VP2800BTD, VP2000BTD specifications

The Vanguard Heating VP2800BTD and VP2000BTD are two innovative heating solutions designed to meet the demands of homeowners seeking efficient and reliable comfort during cold weather. These models combine advanced technology with user-friendly features to provide effective warmth while promoting energy savings.

One of the standout features of both the VP2800BTD and VP2000BTD is their high heating efficiency. The units utilize a powerful heating element that ensures rapid warm-up times, allowing homeowners to enjoy the benefits of immediate heat. This efficiency translates into reduced energy consumption, making these heaters an economical choice for many households, especially during the colder months.

Both models come equipped with adjustable thermostats, allowing users to set their desired temperature with precision. This feature ensures that the heating system operates only as needed, further enhancing energy efficiency and comfort. Moreover, the digital display on each model makes it easy to monitor and adjust settings, contributing to an effortless user experience.

In terms of safety, Vanguard Heating has incorporated multiple protective features into both the VP2800BTD and VP2000BTD. These heaters are equipped with overheat protection, which automatically shuts off the unit if it reaches a dangerously high temperature. Additionally, a safety tip-over switch ensures that if the unit is accidentally knocked over, it will immediately turn off, providing peace of mind for households with pets or young children.

The design of the VP2800BTD and VP2000BTD models also contributes to their appeal. Both units feature a sleek, modern aesthetic that fits seamlessly into various styles of home décor. They are compact, making them easy to place in different rooms without taking up too much space.

Furthermore, these heaters operate quietly, allowing users to maintain a comfortable atmosphere without the distraction of noisy machinery. This is particularly important for bedrooms, offices, or areas where tranquility is desired.

In summary, Vanguard Heating's VP2800BTD and VP2000BTD models stand out for their efficiency, user-friendly features, robust safety protocols, and appealing design. These units represent a harmonious blend of technology and functionality, making them excellent choices for anyone looking to enhance their indoor comfort during the winter months.