Vanguard Heating VP2000BTD, VP2800BTD installation manual AIR for Combustion Ventilation

Page 5

OWNER’S MANUAL

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

 

___________________ Btu/Hr

 

 

 

 

Gas water heater*

 

___________________ Btu/Hr

Example:

 

 

 

Gas furnace

 

___________________ Btu/Hr

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

 

___________________ Btu/Hr

Vent-free heater

+

20,000

Btu/Hr

Gas fireplace logs

 

___________________ Btu/Hr

 

Total

=

60,000

Btu/Hr

Other gas appliances* +

___________________ Btu/Hr

 

 

 

 

Total

=

___________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 60,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

104401

5

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualBlue Flame PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating HeaterInstalling Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Replacement Parts SpecificationsAccessories Technical ServiceVP2000BTD VP2800BTD ODS/Pilot AssemblyIllustrated Parts Breakdown KEY Part Number for VP2000BTD VP2800BTD Description QTY Parts ListWarranty Information

VP2800BTD, VP2000BTD specifications

The Vanguard Heating VP2800BTD and VP2000BTD are two innovative heating solutions designed to meet the demands of homeowners seeking efficient and reliable comfort during cold weather. These models combine advanced technology with user-friendly features to provide effective warmth while promoting energy savings.

One of the standout features of both the VP2800BTD and VP2000BTD is their high heating efficiency. The units utilize a powerful heating element that ensures rapid warm-up times, allowing homeowners to enjoy the benefits of immediate heat. This efficiency translates into reduced energy consumption, making these heaters an economical choice for many households, especially during the colder months.

Both models come equipped with adjustable thermostats, allowing users to set their desired temperature with precision. This feature ensures that the heating system operates only as needed, further enhancing energy efficiency and comfort. Moreover, the digital display on each model makes it easy to monitor and adjust settings, contributing to an effortless user experience.

In terms of safety, Vanguard Heating has incorporated multiple protective features into both the VP2800BTD and VP2000BTD. These heaters are equipped with overheat protection, which automatically shuts off the unit if it reaches a dangerously high temperature. Additionally, a safety tip-over switch ensures that if the unit is accidentally knocked over, it will immediately turn off, providing peace of mind for households with pets or young children.

The design of the VP2800BTD and VP2000BTD models also contributes to their appeal. Both units feature a sleek, modern aesthetic that fits seamlessly into various styles of home décor. They are compact, making them easy to place in different rooms without taking up too much space.

Furthermore, these heaters operate quietly, allowing users to maintain a comfortable atmosphere without the distraction of noisy machinery. This is particularly important for bedrooms, offices, or areas where tranquility is desired.

In summary, Vanguard Heating's VP2800BTD and VP2000BTD models stand out for their efficiency, user-friendly features, robust safety protocols, and appealing design. These units represent a harmonious blend of technology and functionality, making them excellent choices for anyone looking to enhance their indoor comfort during the winter months.