Vanguard Heating VP2800BTD, VP2000BTD Lighting Instructions, To Turn OFF GAS To Appliance

Page 12

®

BLUE FLAME PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 3, page 11.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, column 3, page 11. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 17).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Ignitor Button

 

Control Knob

 

PILOT

LO

 

OFF

 

 

HI

 

IGNITOR

Figure 17 - Control Knob In The OFF Position

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through

16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 18 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modu- lating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 8).

2.Follow steps 1 through 5 under Light- ing Procedures.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 2.

5.Replace front panel.

12

104401

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Blue Flame PROPANE/LP GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Installing Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating HeaterManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Specifications Replacement PartsAccessories Technical ServiceODS/Pilot Assembly Illustrated Parts BreakdownVP2000BTD VP2800BTD Parts List KEY Part Number for VP2000BTD VP2800BTD Description QTYWarranty Information

VP2800BTD, VP2000BTD specifications

The Vanguard Heating VP2800BTD and VP2000BTD are two innovative heating solutions designed to meet the demands of homeowners seeking efficient and reliable comfort during cold weather. These models combine advanced technology with user-friendly features to provide effective warmth while promoting energy savings.

One of the standout features of both the VP2800BTD and VP2000BTD is their high heating efficiency. The units utilize a powerful heating element that ensures rapid warm-up times, allowing homeowners to enjoy the benefits of immediate heat. This efficiency translates into reduced energy consumption, making these heaters an economical choice for many households, especially during the colder months.

Both models come equipped with adjustable thermostats, allowing users to set their desired temperature with precision. This feature ensures that the heating system operates only as needed, further enhancing energy efficiency and comfort. Moreover, the digital display on each model makes it easy to monitor and adjust settings, contributing to an effortless user experience.

In terms of safety, Vanguard Heating has incorporated multiple protective features into both the VP2800BTD and VP2000BTD. These heaters are equipped with overheat protection, which automatically shuts off the unit if it reaches a dangerously high temperature. Additionally, a safety tip-over switch ensures that if the unit is accidentally knocked over, it will immediately turn off, providing peace of mind for households with pets or young children.

The design of the VP2800BTD and VP2000BTD models also contributes to their appeal. Both units feature a sleek, modern aesthetic that fits seamlessly into various styles of home décor. They are compact, making them easy to place in different rooms without taking up too much space.

Furthermore, these heaters operate quietly, allowing users to maintain a comfortable atmosphere without the distraction of noisy machinery. This is particularly important for bedrooms, offices, or areas where tranquility is desired.

In summary, Vanguard Heating's VP2800BTD and VP2000BTD models stand out for their efficiency, user-friendly features, robust safety protocols, and appealing design. These units represent a harmonious blend of technology and functionality, making them excellent choices for anyone looking to enhance their indoor comfort during the winter months.