Vanguard Heating VS24PR, VS30PR, VS18PR Installing Heater Base Assembly, Floor Clearances

Page 12

INSTALLING

Continued

Floor Clearances

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combus- tibles (see Figure 8).

14"

Combustible Material

12

Min.

Non-Combustible

Material

Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Hearth

Combustible Material

5"

Min.

Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

INSTALLING HEATER BASE ASSEMBLY

WARNING

You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING

If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting. Raise fireplace floor with non-combustible material. Make sure material is secure.

CAUTION

Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly.

103448

Image 12
Contents VS18PR VS24PR VS30PR What to do if YOU Smell GASContents Safety InformationUnpacking Product Features Safety PilotLocal Codes OperationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceAIR for CombustionVentilation Ventilation AIRInstalling Check GAS TypeInstalling Installation and Clearances Minimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureInstalling If Using MantelMinimum Non Combustible Material Clearances Installing Mantel Clearances See FigureInstalling Heater Base Assembly Floor ClearancesAttaching Base to Fireplace Floor Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing Logs Metal Grate BarFor Your Safety Read Before Lighting Installing OperatingHeater Lighting Instructions Control Knob and Ignitor Button LocationManual Lighting Procedure To Turn OFF GAS to ApplianceThermostat Control Operation Shutting Off HeaterOptional Ghrct Hand Held Remote Operation Operating HeaterInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning MaintenanceTurn off heater and let cool before cleaning ODS/PILOT and BurnersTrouble ShootingTrouble ShootingWiring Diagram Technical ServiceSpecifications Service HintsReplacement Parts Parts Under WarrantyBreakdown Illustrated PartsParts List KEY Part Numbers VS18PR VS24PR VS30PR Description QTYAccessories 103448 Warranty Information Limited Warranty VENT-FREE Propane GAS LOG Heaters

VS18PR, VS30PR, VS24PR specifications

Vanguard Heating offers a range of high-performance heating solutions, including the VS30PR, VS18PR, and VS24PR models. Each unit is engineered to deliver exceptional efficiency and reliability for both residential and commercial heating needs.

The VS30PR model is designed for medium-sized spaces, delivering up to 30,000 BTUs. Its compact design makes it an excellent choice for both homes and businesses where space is at a premium. The VS30PR is equipped with advanced modulating technology, allowing it to adjust its heating output based on the current demand, which significantly enhances energy efficiency. One of its key features is the electronic ignition system that eliminates the need for a standing pilot light, thus enhancing safety and reducing gas consumption.

On the other hand, the VS18PR model is tailored for smaller applications, providing a heating output of up to 18,000 BTUs. This model excels in energy conservation, having earned high efficiency ratings. It includes an integrated fan system that ensures uniform heat distribution throughout the space, mitigating cold spots and enhancing comfort. The VS18PR is ideal for homes with limited heating requirements or smaller commercial spaces. Its durable construction and reliable operation make it a popular choice for those seeking a dependable heating solution without unnecessary excess.

The VS24PR model offers a balanced option for larger areas with a heating capacity of up to 24,000 BTUs. It features dual fuel options, allowing users to switch between natural gas and propane, providing versatility depending on the available fuel source. The VS24PR also includes advanced control systems that allow for programmable settings, enabling users to optimize their heating schedules based on their lifestyle and preferences. An outstanding feature of this model is its compatibility with smart home systems, allowing for remote monitoring and control via smartphone applications.

Overall, Vanguard Heating’s VS30PR, VS18PR, and VS24PR models embody the brand’s commitment to quality, efficiency, and customer satisfaction. Each model incorporates innovative technologies that cater to varying heating needs, ensuring users can find an appropriate solution for their specific requirements. With robust designs and advanced features, these units not only enhance comfort but also contribute to reduced energy costs. Whether for a cozy home setting or a bustling commercial environment, Vanguard Heating’s offerings stand out for their performance and reliability.